Abstract
A connection was made between a single stretcher and 2 headers with 2 threaded nails (Type-A), and another one between 2 stretchers and 2 headers with 4 threaded nails (Type-B) to use as specimens. Type-C was the stretchers that are connected with 2 threaded nails by half lap joint at end-distance 5D to reinforce Type-B, Type-C1 the stretchers that are connected by half lap joint at end-distance 10D, and Type-C2 with 3 threaded nails at end-distance 10D. Compressive shear strength of Type-C, the supplementation of Type-B, was decreased by 30%, compared with that of Type-B. Those of Type-B and Type-C1 that used longer end-distance than Type-C were about the same, and that of Type-C2 connected with 3 threaded nails was 1.28-times stronger than that of Type-C1. Connection of the retaining wall using existing square timber has a problem between long and short stretchers and 2 headers. So it was investigated in the experiment to replace it. Therefore, if Type-B is replaced with Type-C2 in constructing the retaining wall, the crack and the rupture of timber caused by threaded nail as well as construction period can be reduced, and also it can be expected to increase their own strength.
시험 시편은 1개의 횡목과 2개의 종목이 직결나사못 2개로 연결된 접합부(Type-A)와 2개의 횡목과 2개의 종목이 4개의 직결나사못으로 연결된 접합부(Type-B)를 제작하였다. Type-B를 보강하기 위하여 횡목간의 연결부를 끝면거리 5D로 반턱이음하여 2개의 직결나사를 사용한 접합부(Type-C), 끝면거리 10D로 반턱이음한 접합부(Type-C1)와 끝면거리 10D, 직결나사 3개를 사용한 접합부(Type-C2)를 제작하였다. 압축형 전단 내력 시험결과 Type-B의 내력을 기준으로 Type-B를 보완한 Type-C는 약 30% 감소하였고, Type-C에서 끝면거리를 증가시킨 Type-C1은 Type-B와 비슷한 내력을 보였으며, Type-C1에서 직결나사못의 개수를 3개로 증가시킨 Type-C2는 Type-C1과 비교하여 1.28배 내력을 나타냈다. 기존 정각재를 이용한 옹벽의 접합부 중 긴 횡목과 짧은 횡목이 2개의 종목과 연결되는 접합부는 내력이 저하되기 때문에 이를 대체하기 위하여 실험을 실시하였다. 따라서 Type-B를 Type-C2로 대체한다면 옹벽 시공시 직결나사못에 의한 목재의 할렬, 파단과 시공시간이 줄어들고 접합 내력이 증가할 것으로 기대된다.