Abstract

We performed numerical simulation using a DPM (discrete phase model) to identify the optimal operation ranges in two representative PM burners widely used in domestic 500-MW pulverized coal-fired power plants. Recently there has been an increased utilization of low-cost coals such as sub-bituminous coal. We investigate the effects of coal blends on the distribution ratio of coal to air by varying the mass flow rates of pulverized coal and primary air and the particle size. We present and discuss optimal conditions for the distribution ratio of coal to air in PM burners.

국내에서 널리 사용되는 500 MW급 미분탄 화력발전에서 2개의 PM (pollution minimum) 버너의 최적 운전 범위를 확인하기 위하여 DPM (discrete phase model)을 활용하여 수치계산을 수행하였다. 본 연구는 저가의 아역청탄의 활용 증진을 위하여 다양한 조건에서 탄 종별로 연구를 수행하는데 그 목적이 있다. 탄 종별로 미분탄의 질량 유량, 1차 공기의 질량 유량, 그리고 미분탄의 입자 크기 분포를 달리하여 공기/석탄의 분배비의 영향을 조사하였다. 이러한 매개변수에 관하여 PM 버너에서의 공기/석탄의 분배비의 최적운전조건을 도출하고 이에 대해 논의하고자 한다.

Keywords

References

  1. Fan, J., Qian, L., Ma, Y., Sun, P. and Cen, K., 2001, "Computational Modeling of Pulverized Coal Combustion Processes in Tangentially Fired Furnaces," Chem. Eng. J., Vol. 81, pp. 261-269. https://doi.org/10.1016/S1385-8947(00)00212-6
  2. European Commission, 2001, Directiove 2001/80/EC on the Limitation of Emissions of Certain Pollutants into the Air from Large Combustion Plants.
  3. Choi, C. R. and Kim, C. N., 2009, "Numerical Investigation on the Flow, Combustion and NOX Emission Chracteristics in a 500MWe Tangentially Fired Pulverized-Coal Boiler," Fuel, Vol. 88, pp. 1720-1731. https://doi.org/10.1016/j.fuel.2009.04.001
  4. Kokkinos, A., Wasyluk, D., Brower, M. and Barna, J. J., 2000, "Reducing NOX emssions in Tangentially-Fired Boilers - A New Approach," ASME, International Joint Power Generation Conference.
  5. Diez, L., Cortes, C. and Pallares, J., 2007, "Numerical Investigation of NOX emissions from a Tangentially-Fired Utility Boiler Under Convectional and Overfire Air Operation," Fuel, doi:10.1016/j.fuel.2007.07.02.
  6. Hill, S. C. and Douglas Smoot, L., 2000, "Modeling of Nitrogen Oxides Formation and Destruction in Combustion Systems," Progress Energ. Combust. Sci., Vol. 26, pp. 417-458. https://doi.org/10.1016/S0360-1285(00)00011-3
  7. Kang, K. T., Song, J. H., Yoon, M. J., Lee, B.H., Kim, S. M., Chang, Y. J. and Jeon, C. H., 2009, "A Numerical Study on the Effects of SOFA on NOX Emission Reduction in 500MW Class Sub-Bituminous Coal-Fired Boiler," Trans. of the KSME(B)., Vol. 4, pp. 399-408.
  8. Chae, T. Y., Yu, T. U., Bang, B. R., Yang, Y.,2009, "A Numerical Study on Characteristics of Oxy-Pulverized Coal Combustion in a Cornerfiring Boiler of 125MWth Scale," 38th KOSCO Symposium, pp. 65-70.
  9. Fluent 6.2 User's and Tutorial Guide, "Multiple Char Reaction"