DOI QR코드

DOI QR Code

Inelastic design of high-axially loaded concrete columns in moderate seismicity regions

  • 투고 : 2010.11.16
  • 심사 : 2011.05.25
  • 발행 : 2011.08.25

초록

In regions of high seismic risk, high-strength concrete (HSC) columns of tall buildings are designed to be fully ductile during earthquake attack by providing substantial amount of confining steel within the critical region. However. in areas of low to moderate seismic risk, the same provision of confining steel is too conservative because of the reduced seismic demand. More critically, it causes problematic steel congestion in the beam-column joints and column critical region. This will eventually affect the quality of concrete placing owing to blockage. To relieve the problem, the confining steel in the critical region of HSC columns located in low to moderate seismicity regions can be suitably reduced, while maintaining a limited ductility level. Despite the advantage, there are still no guidelines developed for designing limited ductility HSC columns. In this paper, a formula for designing limited ductility HSC columns is presented. The validity of the formula was verified by testing half-scale HSC columns subjected to combined high-axial load and flexure, in which the confining steel was provided as per the proposed formula. From the test results, it is evident that the curvature ductility factors obtained for all these columns were about 10, which is the generally accepted level of limited ductility.

키워드

참고문헌

  1. Ates, S., Soyluk, K., Dumanoglu, A.A. and Bayraktar, A. (2009), "Earthquake response of isolated cable-stayed bridges under spatially varying ground motions", Struct. Eng. Mech., 31(6), 639-662. https://doi.org/10.12989/sem.2009.31.6.639
  2. Altin, S., Kuran, F., Anil, O. and Kara, M.E. (2008), "Rehabilitation of heavily earthquake damaged masonry building using steel straps", Struct. Eng. Mech., 30(6), 651-664. https://doi.org/10.12989/sem.2008.30.6.651
  3. Bae, S. and Bayrak, O. (2008), "Plastic hinge length of reinforced concrete columns", ACI Struct. J., 105(3), 290-300.
  4. Bambach, M.R., Jama, H., Zhao, X.L. and Grzebieta, R.H. (2008), "Hollow and concrete filled steel hollow sections under transverse impact loads", Eng. Struct., 30, 2859-2870. https://doi.org/10.1016/j.engstruct.2008.04.003
  5. Bayrak, O. and Sheikh, S.A. (1998), "Confinement reinforcement design considerations for ductile HSC columns", J. Struct. Eng.-ASCE, 124(9), 999-1010. https://doi.org/10.1061/(ASCE)0733-9445(1998)124:9(999)
  6. Bechtoula, H., Kono, S. and Watanabe, F. (2009), "Seismic performance of high strength reinforced concrete columns", Struct. Eng. Mech., 31(6), 697-716. https://doi.org/10.1016/j.engstruct.2008.11.006
  7. Bindhu, K.R., Jaya, K.P. and Manicka Selvam, V.K. (2008), "Seismic resistance of exterior beam-column joints with non-conventional confinement reinforcement detailing", Struct. Eng. Mech., 30(6), 733-761. https://doi.org/10.1016/j.engstruct.2007.05.019
  8. Chen, Y.H. and Ding, Y.J. (2008), "Passive, semi-active, and active tuned-liquid-column dampers", Struct. Eng. Mech., 30(1), 1-20. https://doi.org/10.1016/j.engstruct.2007.02.016
  9. Chen, S., Jia, Y. and Wang, X. (2009), "Experimental study of moment redistribution and load carrying capacity of externally prestressed continuous composite beams", Struct. Eng. Mech., 31(5), 615-619.
  10. Chung, T.S.K., Lam, E.S.S., Wu, B. and Xu, Y.L. (2009), "Experimental and numerical verification of hydraulic displacement amplification damping system", Struct. Eng. Mech., 33(1), 1-14. https://doi.org/10.12989/sem.2009.33.1.001
  11. EC2, Eurocode 2 (2004), Eurocode 2: Design of Concrete Structures: Part 1-1: General Rules and Rules for Buildings, UK.
  12. Elmenshawi, A. and Brown, T. (2011) "Modelling criteria for R/C elements constructed with ultra-high-strength concrete and subjected to cyclic loading", Struct. Des. Tall Spec., 20(3), 371-386. https://doi.org/10.1002/tal.532
  13. Elremaily, A. and Azizinamini, A. (2002), "Behavior and strength of circular concrete-filled tube columns", J. Constr. Steel Res., 58(12), 1567-1591. https://doi.org/10.1016/S0143-974X(02)00005-6
  14. Ellobody, E. and Young, B. (2006), "Design and behaviour of concrete-filled cold-formed stainless steel tube columns", Eng. Struct., 28, 716-728. https://doi.org/10.1016/j.engstruct.2005.09.023
  15. Englekirk, R.E. (2008), "A call for change in seismic design procedures", Struct. Des. Tall Spec., 17, 1005-1013. https://doi.org/10.1002/tal.490
  16. Feng, R. and Young, B. (2009) "Behaviour of concrete-filled stainless steel tubular X-joints subjected to compression", Thin Wall. Struct., 47(4), 365-374. https://doi.org/10.1016/j.tws.2008.09.006
  17. Fu, C. (2009), "Passive vibration control of plan-asymmetric buildings using tuned liquid column gas dampers", Struct. Eng. Mech., 33(3), 339-355. https://doi.org/10.12989/sem.2009.33.3.339
  18. Ghosh, R.K. and Ghosh, A.D. (2008), "Soil interaction effects on the performance of compliant liquid column damper for seismic vibration control of short period structures", Struct. Eng. Mech., 28(1), 89-105. https://doi.org/10.12989/sem.2008.28.1.089
  19. Hashemi, S.H., Maghsoudi, A.A. and Rahgozar, R. (2008), "Flexural ductility of reinforced HSC beams strengthened CFRP sheets", Struct. Eng. Mech., 30(4), 403-426. https://doi.org/10.12989/sem.2008.30.4.403
  20. Hino, J., Yoshitomi, S., Tsuji, M. and Takewaki, I. (2008), "Bound of aspect ratio of base-isolated buildings considering nonlinear tensile behavior of rubber bearing", Struct. Eng. Mech., 30(3), 351-368. https://doi.org/10.12989/sem.2008.30.3.351
  21. Ho, J.C.M. and Pam, H.J. (2003a), "Influence of transverse steel configuration on post-elastic behaviour of highstrength reinforced concrete columns", Trans. Hong Kong Institut. Eng., 10(2), 1-9.
  22. Ho, J.C.M. and Pam, H.J. (2003b), "Inelastic design of low-axially loaded high-strength reinforced concrete columns", Eng. Struct., 25(8), 1083-1096. https://doi.org/10.1016/S0141-0296(03)00050-6
  23. Ho, J.C.M., Kwan, A.K.H. and Pam, H.J. (2003), "Theoretical analysis of post-peak flexural behaviour of normal- and high-strength concrete beams", Struct. Des. Tall Spec., 12, 109-125. https://doi.org/10.1002/tal.216
  24. Ho, J.C.M. (2011), "Limited ductility design of reinforced concrete columns for tall buildings in low to moderate seismicity regions", Struct. Des. Tall Spec., 20, 102-120. https://doi.org/10.1002/tal.610
  25. Ho, J.C.M., Lam, J.Y.K. and Kwan, A.K.H. (2010), "Effectiveness of adding confinement for ductility improvement of high-strength concrete columns", Eng. Struct., 32, 714-725. https://doi.org/10.1016/j.engstruct.2009.11.017
  26. Inel, M., Ozmen, H.B. and Bilgin, H. (2008), "Seismic performance evaluation of school buildings in Turkey", Struct. Eng. Mech., 30(5), 535-558. https://doi.org/10.12989/sem.2008.30.5.535
  27. Kaklauskas, G., Gribniak, V., Bacinskas, D. and Vainiunas, P. (2009), "Shrinkage influence on tension stiffening in concrete members", Eng. Struct., 31(6), 1305-1312. https://doi.org/10.1016/j.engstruct.2008.10.007
  28. Kavianipour, O. and Sadati, S.H. (2009), "Effects of damping on the linear stability of a free-free beam subjected to follower and transversal forces", Struct. Eng. Mech., 33(6), 709-724. https://doi.org/10.12989/sem.2009.33.6.709
  29. Kim, T.H., Kim, Y.J. and Shin, H.M. (2008a), "Seismic performance assessment of reinforced concrete bridge piers supported by laminated rubber bearings", Struct. Eng. Mech., 29(3), 259-278. https://doi.org/10.12989/sem.2008.29.3.259
  30. Kim, D., Yi, J.H., Seo, H.Y. and Chang, C. (2008b), "Earthquake risk assessment of seismically isolated extradosed bridges with lead rubber bearings", Struct. Eng. Mech., 29(6), 689-707. https://doi.org/10.12989/sem.2008.29.6.689
  31. Kwan, A.K.H. (2000), "Use of condensed silica fume for making high-strength, self-consolidating concrete", Can. J. Civil Eng., 27(4), 620-627. https://doi.org/10.1139/l99-091
  32. Lam, J.Y.K., Ho, J.C.M. and Kwan, A.K.H. (2009a), "Flexural ductility of high-strength concrete columns with minimal confinement", Mater. Struct., 42(7), 909-921. https://doi.org/10.1617/s11527-008-9431-5
  33. Lam, J.Y.K., Ho, J.C.M. and Kwan, A.K.H. (2009b), "Maximum axial load level and minimum confinement for limited ductility design of concrete columns", Comput. Concrete, 6(5), 357-376. https://doi.org/10.12989/cac.2009.6.5.357
  34. Lew, M. (2007), "Design of tall buildings in high-seismic regions", Struct. Des. Tall Spec., 16, 537-541. https://doi.org/10.1002/tal.436
  35. Li, B., Park, R. and Tanaka, H. (1991), "Effect of confinement on the behaviour of high strength concrete columns under seismic loading", Proceedings, Pacific Conference on Earthquake Engineering, Auckland, November.
  36. Li, C. and Xiong, X. (2008), "Estimation of active multiple tuned mass dampers for asymmetric structures", Struct. Eng. Mech., 29(5), 505-530. https://doi.org/10.12989/sem.2008.29.5.505
  37. Logan, A., Choi, W., Mirmiran, A., Rizkalla, S. and Zia, P. (2009), "Short-term mechanical properties of highstrength concrete", ACI Mater. J., 106(5), 413-418.
  38. Lu, X. and Hsu, C.T.T. (2007), "Tangent Poisson's ratio of high-strength concrete in triaxial compression", Mag. Concrete Res., 59(1), 69-77. https://doi.org/10.1680/macr.2007.59.1.69
  39. Lu, X. and Zhou, Y. (2007), "An applied model for steel reinforced concrete columns", Struct. Eng. Mech., 27(6), 697-711. https://doi.org/10.12989/sem.2007.27.6.697
  40. Maghsoudi, A.A. and Bengar, H.A. (2006), "Flexural ductility of HSC members", Struct. Eng. Mech., 24(2), 195-212. https://doi.org/10.12989/sem.2006.24.2.195
  41. Mirmiran, A. and Shahawy, M. (1997), "Dilation characteristics of confined concrete", Mech. Cohes. Frict. Mater., 2, 237-249. https://doi.org/10.1002/(SICI)1099-1484(199707)2:3<237::AID-CFM32>3.0.CO;2-2
  42. Pam, H.J. and Ho, J.C.M. (2001), "Flexural strength enhancement of confined reinforced concrete columns", Proceedings, Institution of Civil Engineers, Structures and Buildings, 146(4), 363-370.
  43. Pam, H.J., Kwan, A.K.H. and Ho, J.C.M. (2001), "Post-peak behavior and flexural ductility of doubly reinforced normal- and high-strength concrete beams", Struct. Eng. Mech., 12(5), 459-474. https://doi.org/10.12989/sem.2001.12.5.459
  44. Pam, H.J. and Ho, J.C.M. (2009), "Length of critical region for confinement steel in limited ductility highstrength reinforced concrete columns", Eng. Struct., 31, 2896-2908. https://doi.org/10.1016/j.engstruct.2009.07.015
  45. Park, R. and Paulay, T. (1975), Reinforced Concrete Structures, John Wiley & Sons, New York, USA.
  46. Park, R. (1982), "Ductility of square-confined concrete columns", J. Struct. Eng.-ASCE, 108ST(2), 929-950.
  47. Park, R. (2001), "Improving the resistance of structures to earthquakes", B. N.Z. Nat. Soc. Earthq. E., 34(1), 1-39.
  48. Paultre, P., Legeron, F. and Mongeau, D. (2001), "Influence of concrete strength and transverse reinforcement yield strength on behaviour of high-strength concrete columns", ACI Struct. J., 98(4), 490-501.
  49. Sadjadi, R. and Kianoush, M.R. (2010), "Application of fiber element in the assessment of the cyclic loading behavior of RC columns", Struct. Eng. Mech., 34(3), 301-317. https://doi.org/10.12989/sem.2010.34.3.301
  50. Su, R.K.L., Lam, W.Y. and Pam, H.J. (2009) "Experimental study of plate-reinforced composite deep coupling beams", Struct. Des. Tall Spec., 18, 235-257. https://doi.org/10.1002/tal.407
  51. Tsang, H.H., Su, R.K.L., Lam, N.T.K. and Lo, S.H. (2009), "Rapid assessment of seismic demand in existing building structures", Struct. Des. Tall Spec., 18, 427-439. https://doi.org/10.1002/tal.444
  52. Watson, S. and Park, R. (1994), "Simulated seismic load tests on reinforced concrete columns", J. Struct. Eng.- ASCE, 120(6), 1825-1849. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:6(1825)
  53. Watson, S., Zahn, F.A. and Park, R. (1994), "Confining reinforcement for concrete columns", J. Struct. Eng.- ASCE, 120(6), 1799-1824.
  54. Weerheijm, J., Mediavilla, J. and van Doormaal, J.C.A.M. (2009), "Explosive loading of multi storey RC buildings: Dynamic response and progressive collapse", Struct. Eng. Mech., 32(2), 193-212. https://doi.org/10.12989/sem.2009.32.2.193
  55. Wu, W.J. and Cai, C.S. (2009), "Comparison of deck-anchored damper and clipped tuned mass damper on cable vibration reduction", Struct. Eng. Mech., 32(6), 741-754. https://doi.org/10.12989/sem.2009.32.6.741
  56. Wu, Y.F., Oehlers, D.J. and Griffith, M.C. (2004), "Rational definition of the flexural deformation capacity of RC column sections", Eng. Struct., 26, 641-650. https://doi.org/10.1016/j.engstruct.2004.01.001
  57. Wu, Y.F. and Wei, Y.Y. (2010), "Effects of cross-sectional aspect ratio on the strength of CFRP-confined rectangular concrete columns", Eng. Struct., 32, 32-45. https://doi.org/10.1016/j.engstruct.2009.08.012
  58. Yagob, O., Galal, K. and Naumoski, N. (2009), "Progressive collapse of reinforced concrete structures", Struct. Eng. Mech., 32(6), 771-786. https://doi.org/10.12989/sem.2009.32.6.771
  59. Yan, Z.H. and Au, F.T.K. (2010), "Nonlinear dynamic analysis of frames with plastic hinges at arbitrary locations", Struct. Des. Tall Spec., 19, 778-801.
  60. Zhang, G., Liu, B., Bai, G. and Liu, J. (2009), "Experimental study on seismic behavior of high strength reinforced concrete frame columns with high axial compression ratios", Struct. Eng. Mech., 33(5), 653-656. https://doi.org/10.12989/sem.2009.33.5.653
  61. Zhu, Y. and Su, R.K.L. (2010), "Seismic behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 2: Evaluation of theoretical strength", Struct. Eng. Mech., 34(5), 563-580. https://doi.org/10.12989/sem.2010.34.5.563

피인용 문헌

  1. Performance of HSC columns under severe cyclic loading vol.13, pp.2, 2015, https://doi.org/10.1007/s10518-014-9617-x
  2. Uni-axial behaviour of normal-strength CFDST columns with external steel rings vol.13, pp.6, 2012, https://doi.org/10.12989/scs.2012.13.6.587
  3. Potentials of elastic seismic design of twisted high-rise steel diagrid frames vol.18, pp.1, 2015, https://doi.org/10.12989/scs.2015.18.1.121
  4. Strength of biaxially loaded high strength reinforced concrete columns vol.44, pp.5, 2012, https://doi.org/10.12989/sem.2012.44.5.649
  5. Uni-axial behaviour of normal-strength concrete-filled-steel-tube columns with external confinement vol.3, pp.6, 2012, https://doi.org/10.12989/eas.2012.3.6.889
  6. Seismic Performance of Wind-Designed Diagrid Tall Steel Buildings in Regions of Moderate Seismicity and Strong Wind vol.14, pp.2, 2013, https://doi.org/10.12989/scs.2013.14.2.155
  7. Seismic performance evaluation of high-rise steel buildings dependent on wind exposures vol.11, pp.3, 2011, https://doi.org/10.1177/1687814019835111