- ABAQUS. (2007), ABAQUS Standard User's Manual, Version 6.7.2, Dassault Systemes Corp., Providence, RI, USA.
- ACI 440.2R-08. (2008), Guide for the Design and Construction of Externally Bonded FRP Systems for Strengthening Concrete Structures, American Concrete Institute, Farmington Hills, MI, USA.
- ASTM D3039/D3039M. (2006), Standard Test Method for Tensile Properties of Polymer Matrix Composite Material, American Society for Testing and Materials, West Conshohocken, PA., USA.
- Bisby, L. A., Green, M. F. and Kodur, V. K. R. (2005a), "Modeling the behavior of fiber reinforced polymer-confined concrete columns exposed to fire", ASCE J. Comp. Const., 9(1), 15-24. https://doi.org/10.1061/(ASCE)1090-0268(2005)9:1(15)
- Bisby, L. A., Kodur, V. K. R. and Green, M. F. (2005b), "Fire endurance of fiber-reinforced polymer-confined concrete columns", ACI Struct. J., 102(6), 883-891.
- CECS24:90. (1990). Regulation of Application Technology of Fire Resistive Coating for Steel Structure. China Association for Engineering Construction Standardization, Beijing, China (in Chinese).
- Chowdhury, E. U., Bisby, L. A., Green, M. F. and Kodur, V. K. R. (2007), "Investigation of insulated FRP-wrapped reinforced concrete columns in fire", Fire. Safety. J., 42(6-7), 452-460. https://doi.org/10.1016/j.firesaf.2006.10.007
- Chowdhury, E. U., Bisby, L. A., Green, M. F. and Kodur, V. K. R. (2008), "Residual behavior of fire-exposed reinforced concrete beams prestrengthed in flexure with fibre-reinforced polymer sheets", J. Comp. Const., ASCE, 12(1), 61-58. https://doi.org/10.1061/(ASCE)1090-0268(2008)12:1(61)
- GB 50016-2006. (2006), Code of Design on Building Fire Protection and Prevention, Chinese standard, Beijing, China (in Chinese).
- Griffis, C. A., Masumura, R. A. and Chang, C. I. (1981), "Thermal response of graphite epoxy composite subjected to rapid heating", J. Comp. Mater., 15(5), 427-442. https://doi.org/10.1177/002199838101500503
- Han, L. H. (2007), Concrete Filled Steel Tubular Structures Theory and Practice, China Science Press, Beijing, China (in Chinese).
- Han, L. H., Yang, Y. F. and Xu, L. (2003), "An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns", J. Const. Steel. Res., 59(4), 427-452. https://doi.org/10.1016/S0143-974X(02)00041-X
- Han, L. H. and Yao, G. H. (2004), "Experimental behaviour of thin-walled hollow structural steel (HSS) columns filled with self-consolidating concrete (SCC)", Thin.Walled. Struct., 42(9),1357-1377. https://doi.org/10.1016/j.tws.2004.03.016
- Han, L. H., Zheng, Y. Q. and Teng, J. G. (2006), "Fire resistance of RC and FRP-confined RC columns", Magazine.Concr. Res., 58(8), 533-546. https://doi.org/10.1680/macr.2006.58.8.533
-
Hao, J. Y., Hu, A. J., Gao, S. Q., Wang, X. C. and Yang, S. Y. (2001), "Processable polyimides with high glass transition temperature and high storage modulus retention at
$400^{\circ}C$ ", High Performance Polymers, 13(3), 211-224. https://doi.org/10.1088/0954-0083/13/3/312 - Hawileh, R. A., Naser, M., Zaidan, W. and Rasheedb, H. A. (2009), "Modeling of insulated CFRP-strengthened reinforced concrete T-beam exposed to fire", Eng. Struct., 31(12), 3072-3079. https://doi.org/10.1016/j.engstruct.2009.08.008
- Hong, S. and Varma, A. H. (2009), "Analytical modeling of the standard fire behavior of loaded CFT columns", J. Const. Steel. Res., 65(1), 54-69. https://doi.org/10.1016/j.jcsr.2008.04.008
- Hu, K. X., He, G. S. and Lu, F. (2007), "Experimental study on fire protection methods of reinforced concrete beams strengthened with carbon fiber reinforced polymer", Frontiers of Architecture and Civil Engineering in China, 1(4), 399-404. https://doi.org/10.1007/s11709-007-0054-7
- ISO 834. 1999. Fire-resistance tests Elements of building construction-Part 1: General requirements, ISO 834-1, International Organization for Standardization, Geneva, Switzerland.
- Ji, G., Li, G., Li, X., Pang, S. S. and Jones, R. (2008), "Experimental study of FRP tube encased concrete cylindersexposed to fire", Com. Struct., 85(2), 149-154. https://doi.org/10.1016/j.compstruct.2007.10.013
- Kodur, V. K. R., Bisby, L. A. and Green, M. F. (2006), "Experimental evaluation of the fire behaviour of insulatedfibre-reinforced-polymer-strengthened reinforced concrete columns", Fire Safety Journal, 41(7), 547-557. https://doi.org/10.1016/j.firesaf.2006.05.004
- Kodur, V. K. R., Bisby, L. A. and Green, M. F. (2007), "Preliminary guidance for the design of FRP-strengthened concrete members exposed to fire", J. Fire. Protec. Eng., 17(1), 5-26. https://doi.org/10.1177/1042391507061956
- Lam, D. and Gardner, L. (2008), "Structural design of stainless steel concrete filled columns", J. Const. Steel. Res., 64(11), 1275-1282. https://doi.org/10.1016/j.jcsr.2008.04.012
- Lie, T. T. (1994). "Fire resistance of circular steel columns filled with bar-reinforced concrete", J. Struct. Eng., ASCE, 120(5), 1489-1509. https://doi.org/10.1061/(ASCE)0733-9445(1994)120:5(1489)
- Lin, P. Z., Zhu, Z. C. and Li, Z. J. (1997), "Fire resistance structure: The concrete filled steel tubular column", Conference Report of International Conference on Composite Construction Conventional and Innovative, Innsbruck, Austria. p. 397-401.
- Liu, F., Wu, B. and Wei, D. (2009), "Failure modes of reinforced concrete beams strengthened with carbon fiber sheet in fire", Fire Safety Journal, 44(7), 941-950. https://doi.org/10.1016/j.firesaf.2009.05.006
- Lu, H., Zhao, X. L. and Han, L. H. (2009), "Fire behaviour of high strength self-consolidating concrete filled steel tubular stub columns", J. Const. Steel. Res., 65(10-11), 1995-2010. https://doi.org/10.1016/j.jcsr.2009.06.013
- Park, S. H., Choi, S. M. and Chung, K. S. (2008), "A Study on the fire-resistance of concrete-filled steel square tube columns without fire protection under constant central axial loads", Steel. Comp. Struct., 8(6), 491-510. https://doi.org/10.12989/scs.2008.8.6.491
- Tao, Z. and Han, L. H. (2007), "Behaviour of fire-exposed concrete-filled steel tubular beam-columns repaired with CFRP wraps", Thin. Walled. Struct., 45(1), 63-76. https://doi.org/10.1016/j.tws.2006.11.004
- Tao, Z., Han, L. H. and Wang, L. L. (2007a), "Compressive and flexural behaviour of CFRP repaired concrete-filled steel tubes after exposure to fire", J. Constr. Steel. Res., 63(8), 1116-1126. https://doi.org/10.1016/j.jcsr.2006.09.007
- Tao, Z., Han, L. H. and Zhuang, J. P. (2007b), "Axial loading behavior of CFRP strengthened concrete-filled steel tubular stub columns", Advan. Struct. Eng., 10(1), 37-46. https://doi.org/10.1260/136943307780150814
- Tao, Z., Han, L. H. and Zhuang, J. P. (2008), "Cyclic performance of fire-damaged concrete-filled steel tubular beam-columns repaired with CFRP wraps", J. Const. Steel. Res., 64(1), 37-50. https://doi.org/10.1016/j.jcsr.2007.02.004
- Tao, Z. and Yu, Q. (2006), New Types of Composite Columns Experiments, Theory and Methodology, China Science Press, Beijing (in Chinese).
- Teng, J. G. (2006), "Structural applications of FRP composites in construction", In: Proceedings of the First International Forum on Advances in Structural Engineering, Beijing, China. p. 354-392.
- Teng, J. G., Chen, J. F., Smith, S. T. and Lam, L. (2002), FRP-Strengthened RC Structures, John Wiley & Sons, Ltd.
- Uy, B. and Patil, S. B. (2006), "Concrete filled high strength steel box columns for tall buildings: Behaviour and design", The Structural Design of Tall Buildings, 5(2), 75-94.
- Wang, Q. L., Guan, C. W. and Zhao, Y. H. (2004), "Theoretical analysis about concentrically compressed concrete filled hollow CFRP-steel stub columns with circular cross-section", In: Proceedings of the Second International Conference on the Steel & Composite Structures, Seoul, Korea. p. 684 (full paper on CD-ROM).
- Wang, T. and Xu, Z. (1997), "The mechanism of epoxy modification of cement mortar", J. Nanjing. Univ. Chemical. Techno., 19(2), 26-32 (in Chinese).
- Wang, Z. B., Tao, Z., Uy, B. and Han, L. H. (2009), "Analysis of FRP-strengthened concrete-filled steel tubular columns under axial compression", In: Proceedings of the First International Postgraduate Conference on Infrastructure and Environment, Hong Kong, China. p. 485-492.
- Williams, B., Kodur, V., Green, M. F. and Bisby, L. (2008), "Fire endurance of fiber-reinforced polymer strengthened concrete T-beams", ACI. Struct. J., 105(1), 60-67.
- Xiao, Y., He, W. H. and Choi, K. K. (2005), "Confined concrete-filled tubular columns", J. Struct. Eng., ASCE, 131(3), 488-497. https://doi.org/10.1061/(ASCE)0733-9445(2005)131:3(488)
- Zhao, X. L. and Han, L. H. (2006), "Double skin composite construction", Prog. Struct. Eng. Mater., 8(3), 93-102. https://doi.org/10.1002/pse.216
- Zhao, X. L. and Zhang, L. (2007), "State-of-the-art review on FRP strengthened steel structures", Eng. Struct., 29(8), 1808-1823. https://doi.org/10.1016/j.engstruct.2006.10.006
- Zhuang, J. P. (2006), Research on Cyclic Behavior of FRP-Strengthened Concrete-Filled Steel Tubular Columns after Fire, Master's thesis, College of Civil Engineering, Fuzhou University (in Chinese).
Cited by
- Repair of Fire-Exposed Preloaded Rectangular Concrete Columns by Postcompressed Steel Plates vol.140, pp.3, 2014, https://doi.org/10.1061/(ASCE)ST.1943-541X.0000884
- Flexural Performances of Square Concrete Filled CFRP-Steel Tubes (S-CF-CFRP-ST) vol.18, pp.8, 2015, https://doi.org/10.1260/1369-4332.18.8.1319
- Behaviour of CFRP externally-reinforced circular CFST members under combined tension and bending vol.106, 2015, https://doi.org/10.1016/j.jcsr.2014.12.007
- Static behavior of axially compressed square concrete filled CFRP-steel tubular (S-CF-CFRP-ST) columns with moderate slenderness vol.110, 2017, https://doi.org/10.1016/j.tws.2016.10.019
- Fire performance curves for unprotected HSS steel columns vol.15, pp.6, 2013, https://doi.org/10.12989/scs.2013.15.6.705
- Strengthening of steel structures with fiber-reinforced polymer composites vol.78, 2012, https://doi.org/10.1016/j.jcsr.2012.06.011
- Seismic performance of FRP-reinforced concrete-filled thin-walled steel tube considering local buckling vol.37, pp.9, 2018, https://doi.org/10.1177/0731684418756514
- Residual strength capacity of fire-exposed circular concrete-filled steel tube stub columns vol.6, pp.5, 2011, https://doi.org/10.12989/acc.2018.6.5.485
- Repair of Fire-Damaged Reinforced Concrete Members with Axial Load: A Review vol.11, pp.4, 2019, https://doi.org/10.3390/su11040963
- Behavior of Circular Fiber-Reinforced Polymer-Steel-Confined Concrete Columns Subjected to Reversed Cyclic Loads: Experimental Studies and Finite-Element Analysis vol.145, pp.9, 2019, https://doi.org/10.1061/(asce)st.1943-541x.0002373
- Monotonic axial compressive behaviour and confinement mechanism of square CFRP-steel tube confined concrete vol.217, pp.None, 2011, https://doi.org/10.1016/j.engstruct.2020.110802
- Hysteretic Behavior of Specimens of Circular Concrete-Filled CFRP-Steel Tubular Beam-Column vol.2021, pp.None, 2011, https://doi.org/10.1155/2021/9933884
- Study on load distribution ratio of composite pre-tightened tooth joint by shear nonlinearity vol.40, pp.5, 2021, https://doi.org/10.12989/scs.2021.40.5.747
- Analysis of Bearing Capacity of Circular Concrete Filled CFRP-Steel Tubular Beam-Column vol.26, pp.1, 2022, https://doi.org/10.1007/s12205-021-2103-5