An Analysis on the Construction of Energy Exchange Network to Recover Waste Heat Energy in Pohang Steel Industrial Complex

포항철강산업단지 내부 폐열 회수를 위한 에너지 교환망 구축 방안 분석

  • 이광구 (경일대학교 기계자동차학부) ;
  • 정인경 (한국산업단지공단 경북EIP사업단) ;
  • 전희동 (포항산업과학연구원 CO2 사업단)
  • Received : 2011.08.10
  • Accepted : 2011.10.21
  • Published : 2011.12.30

Abstract

A detailed database of waste heat is built to propose energy exchange networks to recover waste energy in Pohang Steel Industrial Complex. A visualized technique is used to figure out the status of waste heat energy and to suggest potential energy exchange networks. Several energy networks are proposed in terms of temperature level, the amount of available energy, distance, and construction cost. A simple economical assessment is applied to the energy exchange networks which have higher economic potential. Their average payback period is estimated to be 2.8 years. The total amount of energy saving by constructing the proposed energy exchange networks is 4,778 TOE per year. It corresponds to 11,160 ton $CO_2$ reduction with the assumption that the recycled waste energy replaces the use of LNG in energy-demanding companies.

포항철강산업단지에서 발생하는 폐열을 회수하기 위하여 주요 기업의 폐에너지 발생 규모에 대한 데이터베이스를 설문조사를 통해 구축하고, 가시적인 기법을 적용하여 에너지 교환망 구축방안을 고려하였다. 폐열의 온도 수준, 유효에너지 발생량, 폐에너지 발생 기업과 예상 수요 기업의 거리, 구축비용 등의 관점에서 잠재성이 높은 에너지 교환망을 제시하고 경제성을 평가하였다. 최종 제안된 4개 기업의 에너지 교환망의 투자비 회수기간은 평균 2.8년이고, 에너지 절감량은 연간 4,778 TOE로 분석되었다. 현재 사용되는 LNG를 폐열 회수로 대체하면 연간 약 11,160 $CO_2$ ton을 감축할 수 있다.

Keywords

References

  1. Lee, S. J., Yoo, C. K., Choi, S. K., Chun, H. D., and Lee, I. B., "Modeling of Eco-industrial Park (EIP) through Material Flow Analysis (MFA)," Korean Chem. Eng. Res., 44(6), 579-587 (2006).
  2. Greenhouse Gas Verification Center, "Examples of Feasibility Analysis on the Project of Greenhouse Gas Reduction," Workshop on the Project of Greenhouse Gas Reduction, KEMCO, Feb. 12-13, Anmyundo, (2009).
  3. Choi, Y. C., Park, T. J., Hong, J. C., and Cho, S. Y., "A Study on the Characteristics of Waste Heat from the Industrial Complexes for Residential and Commercial Sectors," J. Energy Eng., 8(2), 242-247 (1999).
  4. Lee, D. K., Park, S. U., and Lee, S. J., "An Application Study on the Actual Site for Using Waste Heat," J. Energy Eng., 10(4), 327-334 (2001).
  5. Park, I. H., Park, J. T., and Yoo, S. Y., "An Investigation Study on Fact of Waste Heat of Domestic Industry," Korea J. Air-Conditioning and Refrigeration Eng., 14(10), 811-816 (2002).
  6. Park, J. T., et al., "An Investigation on Waste Heat of Domestic Industry and Optimum Heat Recovery Technology," Report of the Ministry of Commerce, Industry, and Energy, 2003.
  7. Kim, L. H., Chang, W. S., and Hong, J. J., "Development of Technology for Network Construction Using Wide Area Energy," J. Energy Eng., 17(3), 125-138 (2008).
  8. Lee, H., et al., "Network Construction of Waste Heat Recovery in Reheating Furnace of Hot Rolling Mill," Report of Gyeongbuk EIP, KICOX, the Ministry of Knowledge Economy, 2009.
  9. Lee, G. G., "An Investigation on Demand and Supply of Waste Heat for Construction of Energy Exchange Network in Pohang Industrial Complex," Report of Gyeongbuk EIP, KICOX, the Ministry of Knowledge Economy, 2009.
  10. Lee, G. G., Jung, I. G., and Chun, H. D., "A Study on the State of Waste Heat to Construct Energy Exchange Network in Pohang Industrial Complex," KSCT Spring Meeting, May 14, Seoul, (2010).
  11. Lee, G. G., Jung, I. G., and Chun, H. D., "A Study on Construction of Energy Exchange Network for Waste Heat Recovery in Pohang Eco-Industrial Park," Paper No. P-He-4, Renewable Energy 2010, June 27-July 2, Yokohama, (2010).
  12. http://www.kogas.or.kr/kogas_kr/html/customer/customer_08.jsp
  13. http://co2.kemco.or.kr/directory/toe.asp