DOI QR코드

DOI QR Code

Diagnostic performance of cone-beam computed tomography on detection of mechanically-created artificial secondary caries

  • Charuakkra, Arnon (Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University) ;
  • Prapayasatok, Sangsom (Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University) ;
  • Janhom, Apirum (Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University) ;
  • Pongsiriwet, Surawut (Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University) ;
  • Verochana, Karune (Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University) ;
  • Mahasantipiya, Phattaranant (Division of Oral and Maxillofacial Radiology, Department of Oral Biology and Diagnostic Sciences, Faculty of Dentistry, Chiang Mai University)
  • Received : 2011.06.23
  • Accepted : 2011.07.06
  • Published : 2011.12.31

Abstract

Purpose : The aim of this study was to compare the diagnostic accuracy of cone-beam computed tomography (CBCT) images and bitewing images in detection of secondary caries. Materials and Methods : One hundred and twenty proximal slots of Class II cavities were randomly prepared on human premolar and molar teeth, and restored with amalgam (n=60) and composite resin (n=60). Then, artificial secondary caries lesions were randomly created using round steel No. 4 bur. The teeth were radiographed with a conventional bitewing technique and two CBCT systems; Pax-500ECT and Promax 3D. All images were evaluated by five observers. The area under the receiver operating characteristic (ROC) curve ($A_z$) was used to evaluate the diagnostic accuracy. Significant difference was tested using the Friedman test (p value<0.05). Results : The mean $A_z$ values for bitewing, Pax-500ECT, and Promax 3D imaging systems were 0.882, 0.995, and 0.978, respectively. Significant differences were found between the two CBCT systems and film (p=0.007). For CBCT systems, the axial plane showed the greatest $A_z$ value. Conclusion : Based on the design of this study, CBCT images were better than bitewing radiographs in detection of secondary caries.

Keywords

References

  1. Scarfe WC, Farman AG. Cone-beam computed tomography. In: White SC, Pharoah MJ. Oral radiology: principle and interpretation. 6th ed. St. Louis: Mosby; 2009. p. 225-42.
  2. Akdeniz B, Grondahl H, Magnusson B. Accuracy of proximal caries depth measurements: comparison between limited cone beam computed tomography, storage phosphor and film radiography. Caries Res 2006; 40: 202-7. https://doi.org/10.1159/000092226
  3. Tsuchida R, Araki K, Okano T. Evaluation of a limited conebeam volumetric imaging system: comparison with film radiography in detecting incipient proximal caries. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2007; 104: 412-6. https://doi.org/10.1016/j.tripleo.2007.02.028
  4. Haiter-Neto F, Wenzel A, Gotfredsen E. Diagnostic accuracy of cone beam computed tomography scans compared with intraoral image modalities for detection of caries lesions. Dentomaxillofac Radiol 2008; 37: 18-22. https://doi.org/10.1259/dmfr/87103878
  5. Young SM, Lee JT, Hodges RJ, Chang TL, Elashoff DA, White SC. A comparative study of high-resolution cone beam computed tomography and charge-coupled device sensors for detecting caries. Dentomaxillofac Radiol 2009; 38: 445-51. https://doi.org/10.1259/dmfr/88765582
  6. Qu X, Li G, Zhang Z, Ma X. Detection accuracy of in vitro approximal caries by cone beam computed tomography images. Eur J Radiol 2011; 79: e24-7. https://doi.org/10.1016/j.ejrad.2009.05.063
  7. Kayipmaz S, Sezgin OS, Saricaoglu ST, Can G. An in vitro comparison of diagnostic abilities of conventional radiography, storage phosphor, and cone beam computed tomography to determine occlusal and approximal caries. Eur J Radiol 2011; 80: 478-82. https://doi.org/10.1016/j.ejrad.2010.09.011
  8. Zhang ZL, Qu XM, Li G, Zhang ZY, Ma XC. The detection accuracies for proximal caries by cone-beam computerized tomography, film, and phosphor plates. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 111: 103-8. https://doi.org/10.1016/j.tripleo.2010.06.025
  9. Kamburoglu K, Murat S, Yüksel SP, Cebeci AR, Paksoy CS. Occlusal caries detection by using a cone-beam CT with different voxel resolutions and a digital intraoral sensor. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2010; 109: e63-9.
  10. Kidd EA. Diagnosis of secondary caries. J Dent Educ 2001; 65: 997-1000.
  11. Mjor IA, Toffenetti F. Secondary caries: a literature review with case reports. Quintessence Int 2000; 31: 165-79.
  12. Imperiano MT, Khoury HJ, Pontual ML, Montes MA, Silveira MM. Comparative radiopacity of four low-viscosity composites. Braz J Oral Sci 2007; 6: 1278-82.
  13. Nair MK, Tyndall DA, Ludlow JB, May K. Tuned aperture computed tomography and detection of recurrent caries. Caries Res 1998; 32: 23-30. https://doi.org/10.1159/000016426
  14. Espelid I, Tveit AB, Erickson RL, Keck SC, Glasspoole EA. Radiopacity of restorations and detection of secondary caries. Dent Mater 1991; 7: 114-7. https://doi.org/10.1016/0109-5641(91)90056-5
  15. Espelid I, Tveit AB. Diagnosis of secondary caries and crevices adjacent to amalgam. Int Dent J 1991; 41: 359-64.
  16. Matteson SR, Phillips C, Kantor ML, Leinedecker T. The effect of lesion size, restorative material, and film speed on the detection of recurrent caries. Oral Surg Oral Med Oral Pathol 1989; 68: 232-7. https://doi.org/10.1016/0030-4220(89)90199-0
  17. Kang B-C, Farman AG, Scarfe WC, Goldsmith LJ. Mechanical defects in dental enamel vs. natural dental caries: observer differentiation using Ektaspeed Plus film. Caries Res 1996; 30: 156-62. https://doi.org/10.1159/000262153
  18. Nair M, Tyndall D, Ludlow J, May K, Ye F. The effects of restorative material and location on the detection of simulated recurrent caries. A comparison of dental film, direct digital radiography and tuned aperture computed tomography. Dentomaxillofac Radiol 1998; 27: 80-4. https://doi.org/10.1038/sj.dmfr.4600323
  19. Grossman ES, Matejka JM. Histological features of artificial secondary caries adjacent to amalgam restorations. J Oral Rehabil 1999; 26: 737-44. https://doi.org/10.1046/j.1365-2842.1999.00424.x
  20. Hassan B, Metska ME, Ozok AR, van der Stelt P, Wesselink PR. Detection of vertical root fractures in endodontically treated teeth by a cone beam computed tomography scan. J Endod 2009; 35: 719-22. https://doi.org/10.1016/j.joen.2009.01.022
  21. Sanders MA, Hoyjberg C, Chu CB, Leggitt VL, Kim JS. Common orthodontic appliances cause artifacts that degrade the diagnostic quality of CBCT Images. J Calif Dent Assoc 2007; 35: 850-7.
  22. Cevidanes LH, Tucker S, Styner M, Kim H, Chapuis J, Reyes M, et al. Three-dimensional surgical simulation. Am J Orthod Dentofacial Orthop 2010; 138: 361-71. https://doi.org/10.1016/j.ajodo.2009.08.026
  23. Razavi T, Palmer RM, Davies J, Wilson R, Palmer PJ. Accuracy of measuring the cortical bone thickness adjacent to dental implants using cone beam computed tomography. Clin Oral Implants Res 2010; 21: 718-25. https://doi.org/10.1111/j.1600-0501.2009.01905.x
  24. Zhang Y, Zhang L, Zhu X, Lee A, Chambers M, Dong L. Reducing metal artifacts in cone-beam CT images by preprocessing projection data. Int J Radiat Oncol Biol Phys 2007; 67: 924-32. https://doi.org/10.1016/j.ijrobp.2006.09.045
  25. SEDENTEXCT Project [Internet]. Radiation protection: cone beam CT for dental and maxillofacial radiology. Evidence based guidelines 2011 [cited 2011 Oct 24]. Available from: http://www.sedentexct.eu/files/guidelines_final.pdf.

Cited by

  1. Influence of Radiopacity of Dental Composites on the Diagnosis of Secondary Caries: The Correlation Between Objective and Subjective Analyses vol.39, pp.1, 2014, https://doi.org/10.2341/12-377-l
  2. Histological Validation of Cone-Beam Computed Tomography Versus Laser Fluorescence and Conventional Diagnostic Methods for Occlusal Caries Detection vol.33, pp.2, 2011, https://doi.org/10.1089/pho.2014.3831
  3. Sensing of Tooth Microleakage Based on Dental Optical Coherence Tomography vol.2015, pp.None, 2015, https://doi.org/10.1155/2015/984627
  4. Alternative methods to visual and radiographic examinations for approximal caries detection vol.59, pp.3, 2017, https://doi.org/10.2334/josnusd.16-0595
  5. Comparison of Cone-Beam Computed Tomography and Intraoral Radiography in Detection of Recurrent Caries under Composite Restorations vol.28, pp.1, 2017, https://doi.org/10.1590/0103-6440201701248
  6. Diagnostic accuracy of cone-beam computed tomography in detecting secondary caries under composite fillings: an in vitro study vol.51, pp.1, 2011, https://doi.org/10.17096/jiufd.62563
  7. The effect of different exposure parameters on proximal caries detection using the Kodak 9000 3D CBCT system vol.65, pp.4, 2017, https://doi.org/10.1590/1981-863720170002000053256
  8. Quantitative assessment of artefacts and identification of gaps in prosthetic crowns: a comparative in vitro study between periapical radiography and CBCT images vol.50, pp.3, 2011, https://doi.org/10.1259/dmfr.20200134
  9. In vitro comparison of high-definition US, CBCT and periapical radiography in the diagnosis of proximal and recurrent caries vol.50, pp.8, 2011, https://doi.org/10.1259/dmfr.20210026