A Study on measurement for effective isotropic radiated power based power management of the base stations

등가등방성복사전력 기반의 기지국 출력 관리를 위한 측정 연구

  • Received : 2011.10.12
  • Accepted : 2011.11.11
  • Published : 2011.12.30

Abstract

In this paper, a WCDMA experimental base station is constructed for power management of mobile communication base station and effective isotropic radiated power is determined by using received power of pilot channel measured on the line-of sight. The measurement system was constructed by a experimental base station and a measurement receiver and the common pilot channel (CPICH) power of the base station was measured. Effective isotropic radiated power (EIRP) of the base station obtained by the measurement value considering correction factor for the errors represented the difference of 0.5 dB compared to the established EIRP of the base station.

본 논문에서는 WCDMA 실험 기지국을 구성하여 가시거리상에서 측정된 pilot 채널의 수신 전력을 이용하여 기지국의 등가등방성복사전력을 구하였다. 측정시스템은 실험 기지국과 수신부로 구성하였으며 기지국의 pilot 채널인 CPICH 채널 전력을 측정하여 측정 시 발생하는 오차에 대한 보정계수를 고려하였다. 측정값으로부터 계산된 기지국의 등가등방성복 사전력은 기지국에서 설정한 등가등방성복사전력과 비교하여 약 0.5 dB 이하의 오차를 나타내었다.

Keywords

References

  1. 무선설비규칙, 방송통신위원회고시 제2010-1호, 2010.
  2. 한국무선국관리사업단, 무선설비의 공중선전력측정 및 산출방법 연구, 1996.
  3. 조인귀, 윤재훈, "무선기기의 ERP/EIRP 기술 및측정기술 동향," 전자통신동향분석, 한국전자통신연구원, 제23권, 제3호,pp. 144-151, June 2008.
  4. Code of Federal Regulation CFR 47, FCC, USA, 2010.
  5. R. Trautmann, "Radio Monitoring Service in Germany," International Conference on EMCECO, pp. 109-112, June 2007.
  6. Federal Network Agency 홈페이지, 독일 연방네트워크청, 2005.
  7. C. A. Balanis, Antenna Theory Analysis and Design, John Wiley & Son, 2005.
  8. K. Chang, RF and Microwave Wireless Systems, John Wiley & Sons, pp.339-344, 2001.