This paper presents the applicability of NATM Composite Lining method in domestic tunnel construction sites. Firstly, in order to produce high quality PC Panel, optimal steam curing condition is reviewed. And in preparation for fire inside the tunnel, the fire-resistance test of PC Panel is carried out. The constructability of NATM Composite Lining method and the drainage ability of light-weight foamed mortar is also evaluated through field construction test. And PC Panel combination program is developed to calculate the quantity of PC Panel efficiently. Besides, economic evaluation for NATM Composite Lining method is conducted. From this research, it is clearly found that NATM Composite Lining method is applicable to domestic tunnel construction site.

본 연구에서는 NATM Composite 라이닝 공법을 실제 터널 현장에 도입하기 위한 적용성 연구를 수행하였다. 먼저 고품질 PC 패널을 생산하기 위한 최적의 증기양생 조건을 도출하였으며 터널 화재 시 피해를 최소화하기 위해 화재모형 실험을 수행하여 PC 패널 라이닝의 화재 거동 특성을 고찰하였다. 또한 실제 현장에 시험시공을 수행하여 NATM Composite 라이닝 공법의 시공성과 안정성을 확인하였고, 현장 배수실험을 실시하여 경량기포 모르타르의 배수성능을 검토하였다. 그리고 추후 NATM Composite 라이닝 터널 설계 시 효율적으로 PC 패널 라이닝 수량을 산출 할 수 있도록 PC 패널 최적 조합 프로그램을 개발하였으며 공사비 분석 및 VE 평가를 통해 NATM Composite 라이닝 공법의 경제성을 검토하였다. 본 연구 결과 NATM Composite 라이닝 공법은 국내 터널 현장에 충분한 적용성을 갖는 것으로 판단된다.

Keywords

Acknowledgement

Supported by : 국토해양부

References

  1. 고경택, 정해문 (2005), "양생온도에 따른 콘크리트 특성", 한국콘크리트학회지, 제17권 제1호, pp.22-27.
  2. 권희성 (2008), 증기양생을 실시한 고강도 모르타르의 강도발현에 관한 실험적 연구, 석사학위논문, 단국대학교, p.77.
  3. 김형준, 김흥렬, 박경훈, 안찬솔, 권기혁 (2010), "고온화재조건 콘크리트 라이닝의 하중비에 따른 폭렬영향성 및 화재손상특성에 관한 실험적 연구", 한국화재소방학회지, 제24권 제3호, pp.145-151.
  4. 김흥열, 김형준, 조경숙, 이재승, 권기혁 (2009), "터널화재시 콘크리트 라이닝의 폭렬 및 화재손상에 관한 실험적 연구", 한국화재소방학회지, 제23권 제3호, pp.110-120.
  5. 마상준, 강은구, 김동민, 신주열 (2011), "NATM Composite 라이닝 공법 개발을 위한 기초연구", 한국지반공학회지.
  6. 한상훈, 김진근, 송영철 (2000), "콘크리트의 재료역학적 성질에대한 양생온도와 재령의 효과", 한국콘크리트학회논문집, 제12권제6호, pp.23-34.
  7. ACI Committee 517 (1969), "Recommended practice for atmospheric pressure steam curing of concrete", Journal ACI, Vol.66, pp.629-646.
  8. ASTM C 1202 (2010), "Standard Test Method for Electrical Indication of Concrete's Ability to Resist Chloride Ion Penetration".
  9. EFNARC (2006), "Specification and Guidelines for Testing of Passive Fire Protction for Concrete Tunnels Linings", pp.15-27.
  10. Hanson, J. A. (1965), "Optimum steam curing procedures for structural lightweight concrete", Journal ACI, Vol.62, pp.661-672.
  11. ITA Working Group No.6 (2004), "Guidelines for Structural Fire Resistance for Road Tunnels, International Tunnelling Association".
  12. Phan, L. T., and Carino, N. J. (2002), "Effects of Test conditions and mixture Proportion on Behaviour of high-strength Concrete Exposed to high Temperatures", ACI Material Journal
  13. PIARC Committee on Road Tunnel Operation C-5 (2003), "PIARC Proposal on Design Criteria for Resistance to Fire for Road Tunnel Structures".