This paper proposes a cooling stop temperature control(CST) and a phase transformation control(PTR) which aim at obtaining the uniform temperature and quality along the longitudinal direction of the high strength steel on the run-out table(ROT) process. The problems of the temperature control are analyzed for the conventional steel and the new control concepts are derived from a time-temperature transformation(TTT) diagram. The proposed control technologies are verified from the simulation results under the temperature prediction model by the heat transfer governing equation, and the temperature estimation simulator. It is shown through the field test of the hot strip mills that the phase transformation ratio of the high strength steel is considerably improved by the proposed temperature controls.

키워드

참고문헌

  1. Suehiro, M., Oda, T., Senuma, T., and Konishi, S., 1995, "Development of Mathematical Model for Predicting Transformation of High-carbon Steel during Cooling on Runout Table and its Application to On-line Temperature Control of Hot Strip Mill," Nippon Steel Technical Report, No. 67, pp. 49-56.
  2. Oda, T., Kondo, Y., Konishi, S., Murakami, H., Suehiro, M., and Yabuta, T., 1995, "Development of Accurate Control in Hot Strip Mill," The Iron and Steel Institute of Japan, Vol. 81, No. 3, pp. 35-40.
  3. Ditzhuijzen, G. V., 1993, "The Controlled Cooling of Hot Rolled Strip: A Combination of Physical Modeling, Control Problems and Practical Adaptation," IEEE Trans. on Automatic Control, Vol. 38, No. 7, pp. 1060-1065. https://doi.org/10.1109/9.231460
  4. Biswas, S. K., Chen, S., and Satyanarayana, A., 1997, "Optimal Temperature Tracking for Accelerated Cooling Processes in Hot Rolling of Steel," Dynamics and Control, Vol. 7, No. 4, pp. 327-340. https://doi.org/10.1023/A:1008268310234
  5. Leltholf, M. D., and Dahm, J. R., 1989, "Model Reference Control of Runout Table Cooling at LTV," Iron and Steel Engineer, Vol. 66, No. 8, pp. 31-35.
  6. Samaras, N. S., and Simaan, M. A., 1998, "Water-cooled End-point Boundary Temperature Control of Hot Strip via Dynamic Programming," IEEE Transactions on Industry Applications, Vol. 34, No. 6, pp. 1335-1341. https://doi.org/10.1109/28.739019
  7. Samaras, N. S., and Simaan, M. A., 2001, "Optimized trajectory tracking control of multistage dynamic metal-cooling processes," IEEE Transactions on Industry Applications, Vol. 37, No. 3, pp. 920-927. https://doi.org/10.1109/28.924776
  8. Kumar, R. K., Sinha, S. K., and Lahiri, A. K., 2001, "An On-line Parallel Controller for the Runout Table of Hot Strip Mills," IEEE Transactions on Control Systems Technology, Vol. 9, No. 6, pp. 821-830. https://doi.org/10.1109/87.960345
  9. Guan, S., Li, H. X., and Tso, S. K., 2001, "Multivariable Fuzzy Supervisory Control for the Laminar Cooling Process of Hot Rolled Slab," IEEE Transactions on Control Systems Technology, Vol. 9, No. 2, pp. 348-3561. https://doi.org/10.1109/87.911386
  10. Xie, H. B., Jiang, Z. Y., Liu, X. H., Wang, G. D., and Tieu, A. K., 2006, "Prediction of coiling temperature on run-out table of hot strip mill using data mining," Journal of Materials Processing Technology, Vol. 177, Issues 1-3, pp. 121-125. https://doi.org/10.1016/j.jmatprotec.2006.04.089
  11. Hatta, N., and Osakabe, H., 1989, "Numerical Modeling for Cooling Process of a Moving Hot Plate by a Laminar Water Curtain," The Iron and Steel Institute of Japan, Vol. 29, No. 11, pp. 919-925. https://doi.org/10.2355/isijinternational.29.919
  12. Groch, A. G., Gubernat, R., and Birstein, E. R., 1990, "Automatic Control of Laminar Flow Cooling in Continuous and Reversing Hot Strip Mills," Iron and Steel Engineer, Vol. 67, No. 9, pp. 16-20.
  13. Park, C. J., 2008, "CSTC of High Strength Steel for ROT Process in Hot Strip Mills," Journal of Institute of Control, Robotics and Systems, Vol. 14, No. 2, pp. 191-196. https://doi.org/10.5302/J.ICROS.2008.14.2.191