DOI QR코드

DOI QR Code

Applicability Study on Deep Mixing for Urban Construction

심층혼합처리 공법의 도심지 공사 적용성 연구

  • 김영석 (한국건설기술연구원 지반연구실) ;
  • 주진현 (한국건설기술연구원 지반연구실) ;
  • 조용상 (삼성물산 건설부문 TA팀)
  • Received : 2010.11.02
  • Accepted : 2011.01.13
  • Published : 2011.01.31

Abstract

The deep mixing method, which is generally considered as a method for improving soft ground, is assessed in terms of its applicability for urban construction. Using small equipment tailored to perform deep mixing in congested urban areas, deep mixing was performed to reinforce the foundation ground of a retaining wall in a redevelopment site in Seoul. Strengths characteristics, construction vibrations and displacements induced to an adjacent old masonry wall were evaluated by laboratory tests and field monitoring. The results indicate that the strength of ground was improved appropriately whilst the vibrations and displacements induced by deep mixing were slight enough to satisfy the general requirements for construction works in urban environments. Therefore, it is concluded that deep mixing method can be a practical option for foundation methods in urban construction works where minimizing noise and vibrations is an important concern.

본 연구에서는 일반적으로 연약지반 개량 공사에 사용하는 심층혼합처리 공법을 도심지 공사에서 지반개량 공법으로 적용하는 방안을 평가하였다. 심층혼합처리 공법을 협소한 도심지 현장에서도 시공이 가능하도록 소형화시킨 시공 장비를 사용하여 서울 시내 재개발 현장에서 기초 지반개량 목적으로 적용하고 개량한 지반의 강도 특성, 지반교반 시 발생한 진동, 시공위치와 인접한 석축구조물에 발생한 변위를 측정하였다. 강도 시험 및 현장계측 결과 심층혼합처리 공법은 원지반의 강도를 효과적으로 개량시켰으며 시공 시 발생시킨 진동과 인접 구조물에 발생한 변위가 미소하여 도심지 공사에서 요구하는 기준을 만족시키는 것으로 판단되었다. 따라서 심층혼합처리 공법은 소음 및 진동 문제가 중요한 고려사항인 도심지 공사에서 기초공법으로 유용하게 적용할 수 있을 것으로 판단된다.

Keywords

References

  1. Butcher, A. P,, Powell, J. J. M. and Skinner, H. D., "Reuse of Foundations for Urban Sites: A Best Practive Handbook," IHC BRE, 2006.
  2. Bruce, D. A., and M. E. C. Bruce., "The Practitioner's Guide to Deep Mixing," Grouting and Ground Treatment, Proceedings of the Third International Conference, Geotechnical Special Publication No. 120, Ed. L. F. Johnsen, D. A. Bruce, and M. J. Byle, American Society of Civil Engineers, pp. 475-488, 2003.
  3. 한국표준협회, 흙의 일축압축시험 방법 KS F 2314, 2001.
  4. Perera, A. S. R, Al-Tabbaa, A., Reid, J. M., and Stegemann, J. A, "State of Practice Report UK Stabilisation/Solidification Treatment and Remediation Part IV: Testing & Performance Criteria," Department of Civil Engineering, University of Cambridge, 2004.
  5. 주진현,김영석,김학승,조용상 "서울 도심지 내 지반에 시공한 소일-시멘트의 강도 특성", 한국지반공학회 2010년도 봄 학술발표회 논문집, pp. 1206-1211, 2010
  6. 국토해양부, 터널 표준 시방서, 2009.
  7. German National Standard, DIN 4150-3 Vibration in Buildings-Part 3: Effects on Structures, 1999.
  8. British Standard Institute, BS 6472-1: Guide To Evaluation Human Exposure to Vibration in Buildings. Vibration Sources Other than Blasting, 2008.

Cited by

  1. A Study on the Improvement Effect and Field Applicability of the Deep Soft Ground by Ground Heating Method vol.8, pp.6, 2018, https://doi.org/10.3390/app8060852