DOI QR코드

DOI QR Code

Design of Input Filters Considering the Stability of STATCOM Systems

  • Zhao, Guopeng (School of Electrical and Electronic Engineering, North China Electric Power University) ;
  • Liu, Jinjun (School of Electrical Engineering, Xi'an Jiaotong University) ;
  • Han, Minxiao (School of Electrical and Electronic Engineering, North China Electric Power University)
  • Received : 2010.11.14
  • Published : 2011.11.20

Abstract

Previous publications regarding the design and specifications of input filters for STATCOMs usually deal with the input filter only, and seldom pay any attention to the influence of the input filters on the performance of the STATCOM systems. A detailed analysis of the influences of input filters on the stability of STATCOM systems and the corresponding design considerations are presented in this paper. Three types of input filters, L filters, LC filters, and LCL filters, are examined separately. The influences of the parameters of input filters on system stability are investigated through frequency domain methods. With direct current control taken as the major control strategy for the STATCOMs, the different situations when adopting different current detection points are covered in this analysis. A comparison between LC filters and LCL filters is also presented with optimized filter parameters. Based on the analysis, the phase margin, as one of the design considerations for the different types of input filters under different current detection schemes, is discussed. This leads to filter parameters that are different than those of the traditional design. Hardware experimental results verify the validity of the above analysis and design.

Keywords

References

  1. R. Gupta, A. Ghosh, and A. Joshi, "Performance comparison of vscbased shunt and series compensators used for load voltage control in distribution systems," IEEE Trans. Power Del., Vol. 26, No. 1, pp. 268- 278, Jan. 2011. https://doi.org/10.1109/TPWRD.2010.2076341
  2. H. M. Pirouz and M. T. Bina, "Modular multilevel converter based statcom topology suitable for medium-voltage unbalanced systems," Journal of Power Electronics, Vol. 10, No. 5, pp. 572-578, Sep. 2010. https://doi.org/10.6113/JPE.2010.10.5.572
  3. C.-K. Kim, V. Sood, and S.-J. Lee, "Dynamic coordination strategies between hvdc and statcom," Journal of Power Electronics, Vol. 9, No. 6, pp. 892-902, Sep., 2009.
  4. B. Singh, P. Jayaprakash, and D. P. Kothari, "A three-phase four-wire dstatcom for power quality improvement," Journal of Power Electronics, Vol. 8, No. 3, pp. 259-267, Jul. 2008.
  5. B. Singh and J. Solanki, "An improved control approach for dstatcom with distorted and unbalanced ac mains," Journal of Power Electronics, Vol. 8, No. 2, pp. 131-140, Apr. 2008.
  6. B. Singh and R. Saha, "Modeling of 18-pulse statcom for power system applications", Journal of Power Electronics, Vol. 7, No. 2, pp. 146-158, Apr. 2007.
  7. T. C. Y. Wang, Z. Ye, G. Sinha, and X. Yuan, "Output filter design for a grid-interconnected three-phase inverter," in Proceeding of IEEE 34th Annual Power Electronics Specialist Conf., Vol. 2, pp. 779-784, 2003.
  8. M. Liserre, F. Blaabjerg, and S. Hansen, "Design and control of an LCLfilter- based three-phase active rectifier," IEEE Trans. Ind. Appl., Vol. 41, No 5, pp.1281-1291, Sep./-Oct. 2005. https://doi.org/10.1109/TIA.2005.853373
  9. Y. Lang, D. Xu, S. R. Hadianamrei, and H. Ma, "A Novel design method of lcl type utility interface for three-phase voltage source rectifier", in Proceeding of IEEE 36th Power Electronics Specialists Conf., pp. 313 -317, 2005.
  10. T. M. L. de Assis, E. H. Watanabe, L. A. S. Pilotto, and R. B. Sollero, "A new technique to control reactive power oscillations using statcom," in Proceeding of 2002 Harmonics and Quality of Power Conf., pp. 607- 613, 2002.
  11. P. T. Cheng, S. Bhattacharya, and D. Divan, "Experimental verification of dominant harmonic active filter for high power applications," IEEE Trans. Ind. Appl., Vol. 36, No. 2, pp. 567-577, May/Apr. 2000. https://doi.org/10.1109/28.833775
  12. J. Kim, J. Choi, and H. Hong, "Output lc filter design of voltage source inverter considering the performance of controller", in Proceeding of International Conference on Power System Technology, pp. 1659-1664, 2000.
  13. A. K. Guru, J. C. Balda, K. Carr, and Y. Q. Xiang, "Design of a switching-ripple filter for a shunt-connected active power filter," in Proceeding of IEEE Industry Applications Society Annual Meeting, pp. 1364-1368, 1998.
  14. P. A. Dahono, A. Purwadi and Qamaruzzaman, "An LC filter design method for single-phase PWM inverters," in Proceeding of International Conference on Power Electronics and Drive Systems, pp. 571-576, 21-24, 1995.
  15. V. Blasko and V. Kaura, "A novel control to actively damp resonance in input LC filter of a three-phase voltage source converter," IEEE Trans. Ind. Appl., Vol.33, No. 2, pp. 542-550, March-April 1997. https://doi.org/10.1109/28.568021
  16. T. Erika and D. G. Holmes, "Grid current regulation of a three-phase voltage source inverter with an LCL input filter," IEEE Trans. Power Electron., Vol. 18, No. 3, pp.888-895, May 2003. https://doi.org/10.1109/TPEL.2003.810838
  17. C. Wessels, J. Dannehl, and F. W. Fuchs, "Active damping of lcl-filter resonance based on virtual resistor for pwm rectifiers—stability analysis with different filter parameters," in Proceeding of 2008 IEEE Power Electronics Specialists Conf., Rhodes, Greece, pp. 3532-3538, 2008.
  18. M. Routimo and H. Tuusa, "LCL type supply filter for active power filter-comparison of an active and a passive method for resonance damping," in Proceeding of 2007 IEEE Power Electronics Specialists Conf., pp. 2939-2945, 2007.

Cited by

  1. Comprehensive Analysis of LCL Filter Interfaced Cascaded H-Bridge Multilevel Inverter-Based DSTATCOM vol.10, pp.3, 2017, https://doi.org/10.3390/en10030346