DOI QR코드

DOI QR Code

Diagnostic Value of 64-Slice Dual-Source CT Coronary Angiography in Patients with Atrial Fibrillation: Comparison with Invasive Coronary Angiography

  • Zhang, Jian-Jun (Department of Radiology, Zhejiang Hospital) ;
  • Liu, Tie (Department of Radiology, Zhejiang Hospital) ;
  • Feng, Yue (Department of Radiology, Zhejiang Hospital) ;
  • Wu, Wei-Feng (Department of Radiology, Zhejiang Hospital) ;
  • Mou, Cai-Yun (Department of Radiology, Zhejiang Hospital) ;
  • Zhai, Li-Hao (Department of Radiology, Zhejiang Hospital)
  • Published : 2011.08.01

Abstract

Objective: We wanted to evaluate the image quality and diagnostic value of 64-slice dual-source computed tomography (DSCT) coronary angiography in patients with atrial fibrillation (Afib). Materials and Methods: The coronary arteries of 22 Afib patients seen on DSCT were classified into 15 segments and the imaging quality (excellent, good, moderate and poor) and significant stenoses (${\geq}$ 50%) were evaluated by two radiologists who were blinded to the conventional coronary angiography (CAG) results. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) for detecting important coronary artery stenosis were calculated. McNemar test was used to determine any significant difference between DSCT and CAG, and Cohen's Kappa statistics were calculated for the intermodality and interobserver agreement. Results: The mean heart rate was $89 {\pm} 8.3$ bpm (range: 80-118 bpm). A range from 250 msec to 300 msec within the RR interval was the optimal reconstruction interval for the patients with Afib. The respective overall sensitivity, specificity, PPV and NPV values were 74%, 97%, 81% and 96% for reader 1 and 72%, 98%, 85% and 96% for reader 2. No significant difference between DSCT and CAG was found for detecting a significant stenosis (reader 1, p = 1.0; reader 2, p = 0.727). Cohen's Kappa statistics demonstrated good intermodality and interobserver agreement. Conclusion: 64-slice DSCT coronary angiography provides good image quality in patients with atrial fibrillation without the need for controlling the heart rate. DSCT can be used for ruling out significant stenosis in patients with atrial fibrillation with its high NPV for detecting in important stenosis.

Keywords

References

  1. Schoepf UJ, Becker CR, Ohnesorge BM, Yucel EK. CT of coronary artery disease. Radiology 2004;232:18-37 https://doi.org/10.1148/radiol.2321030636
  2. Schoenhagen P, Halliburton SS, Stillman AE, Kuzmiak SA, Nissen SE, Tuzcu EM, et al. Noninvasive imaging of coronary arteries: current and future role of multi-detector row CT. Radiology 2004;232:7-17 https://doi.org/10.1148/radiol.2321021803
  3. Raff GL, Gallagher MJ, O'Neill WW, Goldstein JA. Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography. J Am Coll Cardiol 2005;46:552-557 https://doi.org/10.1016/j.jacc.2005.05.056
  4. Sun Z, Jiang W. Diagnostic value of multislice computed tomography angiography in coronary artery disease: a metaanalysis. Eur J Radiol 2006;60:279-286 https://doi.org/10.1016/j.ejrad.2006.06.009
  5. Heuschmid M, Kuettner A, Schroeder S, Trabold T, Feyer A, Seemann MD, et al. ECG-gated 16-MDCT of the coronary arteries: assessment of image quality and accuracy in detecting stenoses. AJR Am J Roentgenol 2005;184:1413-1419 https://doi.org/10.2214/ajr.184.5.01841413
  6. Pugliese F, Mollet NR, Runza G, van Mieghem C, Meijboom WB, Malagutti P, et al. Diagnostic accuracy of non-invasive 64-slice CT coronary angiography in patients with stable angina pectoris. Eur Radiol 2006;16:575-582 https://doi.org/10.1007/s00330-005-0041-0
  7. Ha EJ, Kim Y, Cheung JY, Shim SS. Coronary artery disease in asymptomatic young adults: its prevalence according to coronary artery disease risk stratification and the CT characteristics. Korean J Radiol 2010;11:425-432 https://doi.org/10.3348/kjr.2010.11.4.425
  8. Flohr TG, McCollough CH, Bruder H, Petersilka M, Gruber K, Suss C, et al. First performance evaluation of a dual-source CT (DSCT) system. Eur Radiol 2006;16:256-268 https://doi.org/10.1007/s00330-005-2919-2
  9. Achenbach S, Ropers D, Kuettner A, Flohr T, Ohnesorge B, Bruder H, et al. Contrast-enhanced coronary artery visualization by dual-source computed tomography--initial experience. Eur J Radiol 2006;57:331-335 https://doi.org/10.1016/j.ejrad.2005.12.017
  10. Johnson TR, Nikolaou K, Wintersperger BJ, Leber AW, von Ziegler F, Rist C, et al. Dual-source CT cardiac imaging: initial experience. Eur Radiol 2006;16:1409-1415 https://doi.org/10.1007/s00330-006-0298-y
  11. Austen WG, Edwards JE, Frye RL, Gensini GG, Gott VL, Griffith LS, et al. A reporting system on patients evaluated for coronary artery disease. Report of the Ad Hoc Committee for Grading of Coronary Artery Disease, Council on Cardiovascular Surgery, American Heart Association. Circulation 1975;51:5-40 https://doi.org/10.1161/01.CIR.51.4.5
  12. Johnson TR, Nikolaou K, Busch S, Leber AW, Becker A, Wintersperger BJ, et al. Diagnostic accuracy of dual-source computed tomography in the diagnosis of coronary artery disease. Invest Radiol 2007;42:684-691 https://doi.org/10.1097/RLI.0b013e31806907d0
  13. Althen JN. Automatic tube-current modulation in CT--a comparison between different solutions. Radiat Prot Dosimetry 2005;114:308-312 https://doi.org/10.1093/rpd/nch501
  14. Pasricha SS, Nandurkar D, Seneviratne SK, Cameron JD, Crossett M, Schneider-Kolsky ME, et al. Image quality of coronary 320-MDCT in patients with atrial fibrillation: initial experience. AJR Am J Roentgenol 2009;193:1514-1521 https://doi.org/10.2214/AJR.09.2319
  15. Oncel D, Oncel G, Tastan A. Effectiveness of dual-source CT coronary angiography for the evaluation of coronary artery disease in patients with atrial fibrillation: initial experience. Radiology 2007;245:703-711 https://doi.org/10.1148/radiol.2453070094
  16. Rist C, Johnson TR, Muller-Starck J, Arnoldi E, Saam T, Becker A, et al. Noninvasive coronary angiography using dual-source computed tomography in patients with atrial fibrillation. Invest Radiol 2009;44:159-167 https://doi.org/10.1097/RLI.0b013e3181948b05
  17. Marwan M, Pflederer T, Schepis T, Lang A, Muschiol G, Ropers D, et al. Accuracy of dual-source computed tomography to identify significant coronary artery disease in patients with atrial fibrillation: comparison with coronary angiography. Eur Heart J 2010;31:2230-2237 https://doi.org/10.1093/eurheartj/ehq223
  18. Leschka S, Scheffel H, Desbiolles L, Plass A, Gaemperli O, Valenta I, et al. Image quality and reconstruction intervals of dual-source CT coronary angiography: recommendations for ECG-pulsing windowing. Invest Radiol 2007;42:543-549 https://doi.org/10.1097/RLI.0b013e31803b93cf
  19. Stein PD, Beemath A, Kayali F, Skaf E, Sanchez J, Olson RE. Multidetector computed tomography for the diagnosis of coronary artery disease: a systematic review. Am J Med 2006;119:203-216 https://doi.org/10.1016/j.amjmed.2005.06.071
  20. Herzog C, Arning-Erb M, Zangos S, Eichler K, Hammerstingl R, Dogan S, et al. Multi-detector row CT coronary angiography: influence of reconstruction technique and heart rate on image quality. Radiology 2006;238:75-86 https://doi.org/10.1148/radiol.2381041595
  21. Leschka S, Wildermuth S, Boehm T, Desbiolles L, Husmann L, Plass A, et al. Noninvasive coronary angiography with 64-section CT: effect of average heart rate and heart rate variability on image quality. Radiology 2006;241:378-385 https://doi.org/10.1148/radiol.2412051384
  22. Scheffel H, Alkadhi H, Plass A, Vachenauer R, Desbiolles L, Gaemperli O, et al. Accuracy of dual-source CT coronary angiography: First experience in a high pre-test probability population without heart rate control. Eur Radiol 2006;16:2739-2747 https://doi.org/10.1007/s00330-006-0474-0
  23. Wang Y, Zhang Z, Kong L, Song L, Merges RD, Chen J, et al. Dual-source CT coronary angiography in patients with atrial fibrillation: comparison with single-source CT. Eur J Radiol 2008;68:434-441 https://doi.org/10.1016/j.ejrad.2008.09.011
  24. Rixe J, Rolf A, Conradi G, Elsaesser A, Moellmann H, Nef HM, et al. Image quality on dual-source computed-tomographic coronary angiography. Eur Radiol 2008;18:1857-1862 https://doi.org/10.1007/s00330-008-0947-4

Cited by

  1. Role of Sonographic Diagnosis in Managing Bethesda Class III Nodules vol.32, pp.11, 2011, https://doi.org/10.3174/ajnr.a2686
  2. Evaluation of Anterior Ethmoidal Artery by 320-Slice CT Angiography with Comparison to Three-Dimensional Spin Digital Subtraction Angiography: Initial Experiences vol.13, pp.6, 2012, https://doi.org/10.3348/kjr.2012.13.6.667
  3. Diagnostic Accuracy and Radiation Dose of CT Coronary Angiography in Atrial Fibrillation: Systematic Review and Meta-Analysis vol.267, pp.2, 2011, https://doi.org/10.1148/radiol.13121224
  4. Prospective ECG-gated coronary 320-MDCT angiography with absolute acquisition delay strategy for patients with persistent atrial fibrillation. vol.201, pp.6, 2013, https://doi.org/10.2214/ajr.12.10140
  5. Computed tomography coronary angiography with a consistent dose below 2 mSv using double prospectively ECG-triggered high-pitch spiral acquisition in patients with atrial fibrillation: initial experie vol.29, pp.6, 2013, https://doi.org/10.1007/s10554-013-0203-0
  6. Coronary CT Angiography in Patients with Atrial Fibrillation vol.7, pp.7, 2014, https://doi.org/10.1007/s12410-014-9274-0
  7. Computed tomography imaging of early coronary artery lesions in stable individuals with multiple cardiovascular risk factors vol.70, pp.4, 2015, https://doi.org/10.6061/clinics/2015(04)04
  8. Does the Reporting Quality of Diagnostic Test Accuracy Studies, as Defined by STARD 2015, Affect Citation? vol.17, pp.5, 2016, https://doi.org/10.3348/kjr.2016.17.5.706
  9. Atrial Fibrillation: Diagnostic Accuracy of Coronary CT Angiography Performed with a Whole-Heart 230-µm Spatial Resolution CT Scanner vol.284, pp.3, 2011, https://doi.org/10.1148/radiol.2017161779
  10. Image quality and radiation dose of coronary CT angiography performed with whole-heart coverage CT scanner with intra-cycle motion correction algorithm in patients with atrial fibrillation vol.28, pp.4, 2011, https://doi.org/10.1007/s00330-017-5131-2
  11. Coronary CT angiography in patients with atrial fibrillation: Standard-dose and low-dose imaging with a high-resolution whole-heart CT scanner vol.28, pp.8, 2011, https://doi.org/10.1007/s00330-017-5282-1
  12. Coronary CT Angiography in Challenging Patients: High Heart Rate and Atrial Fibrillation. A Review vol.26, pp.11, 2011, https://doi.org/10.1016/j.acra.2019.01.022