DOI QR코드

DOI QR Code

Musculoskeletal Applications of Elastography: a Pictorial Essay of Our Initial Experience

  • Lalitha, Pall (Focus Diagnostics, Department of Radiology, Focus Diagnostic Center) ;
  • Reddy, M.Ch. Balaji (Focus Diagnostics, Department of Radiology, Focus Diagnostic Center) ;
  • Reddy, K.Jagannath (Focus Diagnostics, Department of Radiology, Focus Diagnostic Center)
  • Published : 2011.06.01

Abstract

Elastography is an ultrasound-based newer imaging technique that is currently being used for the evaluation of breast lesions and hepatic pathology. It is also being evaluated for characterizing lesions of the prostate, thyroid, cervix and lymph nodes. We have applied real-time sonoelastography to a variety of musculoskeletal pathologies and here we report the findings of elastography for the evaluation of various musculoskeletal pathologies. Elastography of musculoskeletal lesions is not yet being routinely used in clinical practice, but it is being extensively researched.

Keywords

References

  1. Krouskop TA, Dougherty DR, Vinson FS. A pulsed Doppler ultrasonic system for making noninvasive measurements of the mechanical properties of soft tissue. J Rehabil Res Dev 1987;24:1-8
  2. Ginat DT, Destounis SV, Barr RG, Castaneda B, Strang JG, Rubens DJ. US elastography of breast and prostate lesions. Radiographics 2009;29:2007-2016 https://doi.org/10.1148/rg.297095058
  3. Cho N, Moon WK, Park JS, Cha JH, Jang M, Seong MH. Nonpalpable breast masses: evaluation by US elastography. Korean J Radiol 2008;9:111-118 https://doi.org/10.3348/kjr.2008.9.2.111
  4. Ophir J, Cespedes I, Ponnekanti H, Yazdi Y, Li X. Elastography: a quantitative method for imaging the elasticity of biological tissues. Ultrason Imaging 1991;13:111-134 https://doi.org/10.1177/016173469101300201
  5. Lerner RM, Parker KJ, Holen J, Gramiak R, Waag RC. Sonoelasticity: medical elasticity images derived from ultrasound signals in mechanically vibrated targets. Acoust Imaging 1988;16:317-327
  6. Hoyt K, Parker KJ, Rubens DJ. Real-time shear velocity imaging using sonoelastographic techniques. Ultrasound Med Biol 2007;33:1086-1097 https://doi.org/10.1016/j.ultrasmedbio.2007.01.009
  7. Bercoff J, Tanter M, Fink M. Supersonic shear imaging: a new technique for soft tissue elasticity mapping. IEEE Trans Ultrason Ferroelectr Freq Control 2004;51:396-409 https://doi.org/10.1109/TUFFC.2004.1295425
  8. De Zordo T, Fink C, Feuchtner GM, Smekal V, Reindl M, Klauser AS. Real-time sonoelastography findings in healthy Achilles tendons. AJR Am J Roentgenol 2009;193:W134-W138 https://doi.org/10.2214/AJR.08.1843
  9. Trombetti J. Sonoelastography and musculoskeletal imaging:December 23, 2008. http://www.dotmed.com/news/story/7760/?lang=en
  10. Schreiber V, Smekal V, De Zordo T, Fink C, Feuchtner G, Klauser A. Real-time sonoelastography in rotator cuff imaging and comparison to magnetic resonance imaging as gold standard. RSNA 2009 http://rsna2009.rsna.org/search/event_display.cfm?em_id=8016421&printmode=Y&autoprint=N
  11. De Zordo T. Value of real-time sonoelastography in lateral epicondylitis: comparison with clinical examination, ultrasound, and power Doppler ultrasound. Radiological Society of North America 94th Scientific Assembly and Annual Meeting November 30th - December 5th, 2008, Chicago, USA
  12. Botar-Jid C, Vasilescu D, Dudea SM, Damian L, Badea R. Ultrasound elastography in musculoskeletal disorders. Ultraschall in Med, 2008, suppl 1, OP9.9. http://www.hitachimedical-systems.eu/fileadmin/hitachi_en/downloads/hirte-publications-and-communications-clinical-abstracts---musculoskeletal-applications-11-06-10.pdf

Cited by

  1. RE: Musculoskeletal Applications of Elastography: a Pictorial Essay of Our Initial Experience vol.12, pp.5, 2011, https://doi.org/10.3348/kjr.2011.12.5.646
  2. Technical note: Real-time sonoelastography evaluation of Achilles tendon vol.21, pp.4, 2011, https://doi.org/10.4103/0971-3026.90685
  3. Ultrasound elastography for imaging tendons and muscles vol.12, pp.49, 2011, https://doi.org/10.15557/jou.2012.0008
  4. Ultrasound elastography as an objective diagnostic measurement tool for lymphoedema of the treated breast in breast cancer patients following breast conserving surgery and radiotherapy vol.46, pp.4, 2011, https://doi.org/10.2478/v10019-012-0033-z
  5. RE: Few Comments on: "Musculoskeletal Applications of Elastography: A Pictorial Essay of Our Initial Experience" vol.13, pp.2, 2011, https://doi.org/10.3348/kjr.2012.13.2.254
  6. Staging of Hepatic Fibrosis: Comparison of Magnetic Resonance Elastography and Shear Wave Elastography in the Same Individuals vol.14, pp.2, 2011, https://doi.org/10.3348/kjr.2013.14.2.202
  7. Acoustic Radiation Force Impulse Elastography for Focal Hepatic Tumors: Usefulness for Differentiating Hemangiomas from Malignant Tumors vol.14, pp.5, 2011, https://doi.org/10.3348/kjr.2013.14.5.743
  8. Mechanistic basis of manual therapy in myofascial injuries. Sonoelastographic evolution control vol.17, pp.2, 2011, https://doi.org/10.1016/j.jbmt.2012.08.006
  9. Value of adding sonoelastography to conventional ultrasound in patients with congenital muscular torticollis vol.43, pp.12, 2013, https://doi.org/10.1007/s00247-013-2750-x
  10. Ultrasound Elastography of Lateral Epicondylosis: Clinical Feasibility of Quantitative Elastographic Measurements vol.202, pp.5, 2011, https://doi.org/10.2214/ajr.13.11003
  11. Ultrasound elastography in children: Establishing the normal range of muscle elasticity vol.44, pp.2, 2014, https://doi.org/10.1007/s00247-013-2793-z
  12. Sonoelastography for qualitative and quantitative evaluation of superficial soft tissue lesions: a feasibility study vol.24, pp.3, 2011, https://doi.org/10.1007/s00330-013-3069-6
  13. Tendon quality in small unilateral supraspinatus tendon tears. Real-time sonoelastography correlates with clinical findings vol.23, pp.2, 2011, https://doi.org/10.1007/s00167-013-2551-7
  14. A numerical method to detect soft tissue injuries from tissue displacements vol.23, pp.1, 2015, https://doi.org/10.1080/17415977.2014.890612
  15. Real-time Sonoelastography of the Quadriceps Tendon in Patients Undergoing Chronic Hemodialysis vol.34, pp.4, 2011, https://doi.org/10.7863/ultra.34.4.671
  16. The role of sonoelastography in planning percutaneous biopsy of soft tissue tumours vol.23, pp.4, 2015, https://doi.org/10.1177/1742271x15608214
  17. Sonoelastography in the musculoskeletal system: Current role and future directions vol.8, pp.11, 2011, https://doi.org/10.4329/wjr.v8.i11.868
  18. In Vivo Evaluation of the Biomechanical Properties of Optic Nerve and Peripapillary Structures by Ultrasonic Shear Wave Elastography in Glaucoma vol.13, pp.2, 2011, https://doi.org/10.5812/iranjradiol.36849
  19. Quantitative Ultrasound Elastography With an Acoustic Coupler for Achilles Tendon Elasticity : Measurement Repeatability and Normative Values vol.35, pp.1, 2016, https://doi.org/10.7863/ultra.14.11042
  20. Usefulness of strain elastography of the musculoskeletal system vol.35, pp.2, 2011, https://doi.org/10.14366/usg.15072
  21. Sonoelastography on Supraspinatus Muscle-Tendon and Long Head of Biceps Tendon in Korean Professional Baseball Pitchers vol.34, pp.1, 2011, https://doi.org/10.5763/kjsm.2016.34.1.28
  22. Use of Ultrasound Elastography in the Assessment of the Musculoskeletal System vol.81, pp.None, 2016, https://doi.org/10.12659/pjr.896099
  23. Rheumatoid Arthritis Revisited – Advanced Imaging Review vol.81, pp.None, 2011, https://doi.org/10.12659/pjr.899317
  24. Ultrasound elastography in tendon pathology: state of the art vol.46, pp.12, 2011, https://doi.org/10.1007/s00256-017-2726-2
  25. Muscle elastography: a new imaging technique for multiple sclerosis spasticity measurement vol.38, pp.3, 2011, https://doi.org/10.1007/s10072-016-2780-x
  26. Effects of Body Mass Index on Mechanical Properties of the Plantar Fascia and Heel Pad in Asymptomatic Participants vol.38, pp.7, 2011, https://doi.org/10.1177/1071100717702463
  27. Serial Changes of Tendon Histomorphology and Strain Elastography After Induced Achilles Tendinopathy in Rabbits : An In Vivo Study vol.36, pp.4, 2011, https://doi.org/10.7863/ultra.16.02059
  28. Supraspinatus muscle elasticity measured with real time shear wave ultrasound elastography correlates with MRI spectroscopic measured amount of fatty degeneration vol.18, pp.None, 2011, https://doi.org/10.1186/s12891-017-1911-8
  29. Ultrasound elastography and ultrasound tissue characterisation for tendon evaluation vol.15, pp.None, 2018, https://doi.org/10.1016/j.jot.2018.06.003
  30. Ultrasound elastography: compression elastography and shear-wave elastography in the assessment of tendon injury vol.9, pp.5, 2011, https://doi.org/10.1007/s13244-018-0642-1
  31. Shear Wave Elastography in the Diagnosis of Hand Tumours vol.2019, pp.None, 2011, https://doi.org/10.1155/2019/2736529
  32. The value of sonoelastography in the diagnosis of supraspinatus tendinopathy-a comparison study vol.92, pp.1096, 2011, https://doi.org/10.1259/bjr.20180951
  33. Feasibility of Ultrasound-Guided Trigger Point Injection in Patients with Myofascial Pain Syndrome vol.7, pp.4, 2011, https://doi.org/10.3390/healthcare7040118
  34. The Effect of Strength Training on Vastus Lateralis’ Stiffness: An Ultrasound Quasi-Static Elastography Study vol.17, pp.12, 2011, https://doi.org/10.3390/ijerph17124381
  35. Immediate Changes and Recovery of the Supraspinatus, Long Head Biceps Tendon, and Range of Motion after Pitching in Youth Baseball Players: How Much Rest Is Needed after Pitching? Sonoelastography on vol.13, pp.3, 2021, https://doi.org/10.4055/cios20187
  36. Young's Modulus of Bilateral Infraspinatus Tendon Measured in Different Postures by Shear Wave Elastography Before and After Exercise vol.13, pp.5, 2021, https://doi.org/10.1111/os.12989