Preliminary Report of Carotid Artery Stenting Using a Tapered Stent

Tapered Stent를 사용한 경동맥 스텐트 설치술에 대한 예비 보고

  • Jeong, Chang-Woo (Department of Radiology, Chosun University College of Medicine) ;
  • Kim, Dong-Hyun (Department of Radiology, Chosun University College of Medicine) ;
  • Ahn, Seong-Hwan (Department of Neurology, Chosun University College of Medicine) ;
  • Kim, Dong-Uk (Department of Neurology, Chosun University College of Medicine) ;
  • Hong, Seung-Jeong (Department of Radiology, Chosun University College of Medicine) ;
  • Kim, Young-Suk (Department of Radiology, Chosun University College of Medicine) ;
  • Byun, Joo-Nam (Department of Radiology, Chosun University College of Medicine) ;
  • Oh, Jae-Hee (Department of Radiology, Chosun University College of Medicine)
  • 정창우 (조선대학교 의과대학 영상의학과학교실) ;
  • 김동현 (조선대학교 의과대학 영상의학과학교실) ;
  • 안성환 (조선대학교 의과대학 신경과학교실) ;
  • 김동욱 (조선대학교 의과대학 신경과학교실) ;
  • 홍승정 (조선대학교 의과대학 영상의학과학교실) ;
  • 김영숙 (조선대학교 의과대학 영상의학과학교실) ;
  • 변주남 (조선대학교 의과대학 영상의학과학교실) ;
  • 오재희 (조선대학교 의과대학 영상의학과학교실)
  • Published : 2011.10.01

Abstract

Purpose: To analyze the results of carotid artery stenting using a tapered stent and to evaluate the effectiveness of the tapered stent compared to previously reported studies using non-tapered stents. Materials and Methods: From October 2008 to August 2010, elective carotid artery stenting using a tapered stent was attempted in 39 lesions from 36 consecutive patients. Post-procedural complications were evaluated by neurologic symptoms and magnetic resonance imaging. Restenosis or occlusion was evaluated by carotid Doppler ultrasound and computerized tomography with angiography. Newly developed neurologic symptoms were evaluated clinically. Results: The self-expandable tapered stent was placed across the carotid artery stenosis. A total stroke was noted in 3 patients, while a major stroke was noted in 1 patient. On diffusion weighted imaging, new lesions were observed in 15 patients, but 13 patients were clinically silent. Follow-up imaging studies were performed in the 13 clinically silent lesions, and no evidence of restenosis or occlusion was found any of the 13 lesions. During clinical follow-up in 34 lesions from 31 patients, there were newly developed neurological symptoms in only 1 patient. Conclusion: Carotid artery stenting using a tapered stent may be safe and useful for the treatment of carotid artery stenosis.

목적: 본 연구는 내경동맥 팽대부의 협착을 가진 환자에서 tapered stent를 이용한 치료 결과를 분석하고 기존에 보고된 연구를 통해 non-tapered stent의 치료성적과 비교해 보고자 하였다. 대상과 방법: 2008년 10월부터 2010년 8월까지 tapered stent를 이용한 36명의 환자에서 39개 병변에 대해 분석하였다. 시술 후 환자의 임상증상, 자기공명영상을 통해 합병증을 평가하였다. 경동맥 도플러 초음파 및 혈관촬영술을 포함하는 전산화단층촬영을 통해 재협착에 대한 평가를 하였으며, 임상적인 무증상 기간을 평가하였다. 결과: 모든 39예에서 자가팽창성의 tapered stent를 총경동맥 분지부에 설치하였다. 총 3예에서 뇌졸중이 발생하였으며, 이 중 1예에서는 중증 뇌졸중이 발생하였다. 시술 후 확산강조 자기공명영상에서 15예에서 새로운 병변이 관찰되었으나 13예에서 임상증상은 없었다. 13예에서 시행한 추적검사에서 모두 재협착 소견을 보이지 않았다. 임상적인 추적관찰 기간 동안 총 31명 중 1명에서 신경학적 증상이 새롭게 발생하였다. 결론: Tapered stent를 이용한 경동맥 협착의 치료는 안전하고 효과적인 치료법이며, 향후 더 많은 환자를 대상으로 한 추적검사가 필요할 것으로 생각된다.

Keywords

References

  1. Yadav J. Stenting and Angioplasty with Protection in Patients at High Risk for Endarterectomy (SAPPHIRE). Chicago: American Heart Association, 2002
  2. Roubin GS, New G, Iyer SS, Vitek JJ, Al-Mubarak N, Liu MW, et al. Immediate and late clinical outcomes of carotid artery stenting in patients with symptomatic and asymptomatic carotid artery stenosis: a 5-year prospective analysis. Circulation 2001;103:532-537 https://doi.org/10.1161/01.CIR.103.4.532
  3. Endovascular versus surgical treatment in patients with carotid stenosis in the Carotid and Vertebral Artery Transluminal Angioplasty Study (CAVATAS): a randomised trial. Lancet 2001;357:1729-1737 https://doi.org/10.1016/S0140-6736(00)04893-5
  4. Bosiers M, de Donato G, Deloose K, Verbist J, Peeters P, Castriota F, et al. Does free cell area influence the outcome in carotid artery stenting? Eur J Vasc Endovasc Surg 2007;33:135-141; discussion 142-143 https://doi.org/10.1016/j.ejvs.2006.09.019
  5. Hart JP, Peeters P, Verbist J, Deloose K, Bosiers M. Do device characteristics impact outcome in carotid artery stenting? J Vasc Surg 2006;44:725-730; discussion 730-731 https://doi.org/10.1016/j.jvs.2006.06.029
  6. Skelly CL, Gallagher K, Fairman RM, Carpenter JP, Velazquez OC, Parmer SS, et al. Risk factors for restenosis after carotid artery angioplasty and stenting. J Vasc Surg 2006;44:1010-1015 https://doi.org/10.1016/j.jvs.2006.07.039
  7. Kirsch EC, Khangure MS, Morling P, York TJ, McAuliffe W. Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model. AJNR Am J Neuroradiol 2002;23:121-127
  8. Piamsomboon C, Roubin GS, Liu MW, Iyer SS, Mathur A, Dean LS, et al. Relationship between oversizing of self-expanding stents and late loss index in carotid stenting. Cathet Cardiovasc Diagn 1998;45:139-143 https://doi.org/10.1002/(SICI)1097-0304(199810)45:2<139::AID-CCD7>3.0.CO;2-D
  9. Yoon SM, Jo KW, Baik MW, Kim YW. Delayed carotid wallstent shortening resulting in restenosis following successful carotid artery angioplasty and stenting. J Korean Neurosurg Soc 2009;46:495-497 https://doi.org/10.3340/jkns.2009.46.5.495
  10. Brown KE, Usman A, Kibbe MR, Morasch MD, Matsumura JS, Pearce WH, et al. Carotid stenting using tapered and nontapered stents: associated neurological complications and restenosis rates. Ann Vasc Surg 2009;23:439-445 https://doi.org/10.1016/j.avsg.2008.11.007
  11. Barnett HJ, Taylor DW, Eliasziw M, Fox AJ, Ferguson GG, Haynes RB, et al. Benefit of carotid endarterectomy in patients with symptomatic moderate or severe stenosis. North American Symptomatic Carotid Endarterectomy Trial Collaborators. N Engl J Med 1998;339:1415-1425 https://doi.org/10.1056/NEJM199811123392002
  12. Brott T, Adams HP Jr, Olinger CP, Marler JR, Barsan WG, Biller J, et al. Measurements of acute cerebral infarction: a clinical examination scale. Stroke 1989;20:864-870 https://doi.org/10.1161/01.STR.20.7.864
  13. Rajagopal V, Rockson SG. Coronary restenosis: a review of mechanisms and management. Am J Med 2003;115:547-553 https://doi.org/10.1016/S0002-9343(03)00477-7
  14. Schwartz RS, Henry TD. Pathophysiology of coronary artery restenosis. Rev Cardiovasc Med 2002;3 Suppl 5:S4-S9
  15. Hoffmann R, Mintz GS. Coronary in-stent restenosis - predictors, treatment and prevention. Eur Heart J 2000;21: 1739-1749 https://doi.org/10.1053/euhj.2000.2153
  16. Schwartz RS, Huber KC, Murphy JG, Edwards WD, Camrud AR, Vlietstra RE, et al. Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model. J Am Coll Cardiol 1992;19:267-274 https://doi.org/10.1016/0735-1097(92)90476-4
  17. Hoffmann R, Mintz GS, Mehran R, Kent KM, Pichard AD, Satler LF, et al. Tissue proliferation within and surrounding Palmaz-Schatz stents is dependent on the aggressiveness of stent implantation technique. Am J Cardiol 1999;83:1170-1174 https://doi.org/10.1016/S0002-9149(99)00053-3
  18. Sullivan TM, Ainsworth SD, Langan EM, Taylor S, Snyder B, Cull D, et al. Effect of endovascular stent strut geometry on vascular injury, myointimal hyperplasia, and restenosis. J Vasc Surg 2002;36:143-149 https://doi.org/10.1067/mva.2002.122878
  19. Wholey MH, Al-Mubarek N, Wholey MH. Updated review of the global carotid artery stent registry. Catheter Cardiovasc Interv 2003;60:259-266 https://doi.org/10.1002/ccd.10645
  20. Christiaans MH, Ernst JM, Suttorp MJ, van den Berg JC, Overtoom TT, Kelder JC, et al. Restenosis after carotid angioplasty and stenting: a follow-up study with duplex ultrasonography. Eur J Vasc Endovasc Surg 2003;26:141-144 https://doi.org/10.1053/ejvs.2002.1974
  21. Bosiers M, Peeters P, Deloose K, Verbist J, Sievert H, Sugita J, et al. Does carotid artery stenting work on the long run: 5-year results in high-volume centers (ELOCAS Registry). J Cardiovasc Surg (Torino) 2005;46:241-247
  22. de Donato G, Setacci C, Deloose K, Peeters P, Cremonesi A, Bosiers M. Long-term results of carotid artery stenting. J Vasc Surg 2008;48:1431-1440; discussion 1440-1441 https://doi.org/10.1016/j.jvs.2008.07.012
  23. Eskandari MK, Brown KE, Kibbe MR, Morasch MD, Matsumura JS, Pearce WH. Restenosis after carotid stent placement in patients with previous neck irradiation or endarterectomy. J Vasc Interv Radiol 2007;18:1368-1374 https://doi.org/10.1016/j.jvir.2007.07.014
  24. Groschel K, Riecker A, Schulz JB, Ernemann U, Kastrup A. Systematic review of early recurrent stenosis after carotid angioplasty and stenting. Stroke 2005;36:367-373 https://doi.org/10.1161/01.STR.0000152357.82843.9f
  25. Meyers PM, Higashida RT, Phatouros CC, Malek AM, Lempert TE, Dowd CF, et al. Cerebral hyperperfusion syndrome after percutaneous transluminal stenting of the craniocervical arteries. Neurosurgery 2000;47:335-343; discussion 343-345 https://doi.org/10.1097/00006123-200008000-00013
  26. Hart R, Hindman B. Mechanisms of perioperative cerebral infarction. Stroke 1982;13:766-773 https://doi.org/10.1161/01.STR.13.6.766