참고문헌
- Heck SL, Blom P, Berstad A. Accuracy and complications in computed tomography fl uoroscopy-guided needle biopsies of lung masses. Eur Radiol 2006;16:1387-1392 https://doi.org/10.1007/s00330-006-0152-2
- Ohno Y, Hatabu H, Takenaka D, Higashino T, Watanabe H, Ohbayashi C, et al. CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules. AJR Am J Roentgenol 2003;180:1665-1669 https://doi.org/10.2214/ajr.180.6.1801665
- Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 1996;167:105-109 https://doi.org/10.2214/ajr.167.1.8659351
- Westcott JL. Direct percutaneous needle aspiration of localized pulmonary lesions: result in 422 patients. Radiology 1980;137:31-35 https://doi.org/10.1148/radiology.137.1.7422857
- vanSonnenberg E, Casola G, Ho M, Neff CC, Varney RR, Wittich GR, et al. Diffi cult thoracic lesions: CT-guided biopsy experience in 150 cases. Radiology 1988;167:457-461 https://doi.org/10.1148/radiology.167.2.3357956
- Gupta R, Cheung AC, Bartling SH, Lisauskas J, Grasruck M, Leidecker C, et al. Flat-panel volume CT: fundamental principles, technology, and applications. Radiographics 2008;28:2009-2022 https://doi.org/10.1148/rg.287085004
- Aviram G, Schwartz DS, Meirsdorf S, Rosen G, Greif J, Graif M. Transthoracic needle biopsy of lung masses: a survey of techniques. Clin Radiol 2005;60:370-374 https://doi.org/10.1016/j.crad.2004.09.006
- Geraghty PR, Kee ST, McFarlane G, Razavi MK, Sze DY, Dake MD. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate. Radiology 2003;229:475-481 https://doi.org/10.1148/radiol.2291020499
- Haaga JR, Reich NE, Havrilla TR, Alfi di RJ, Meaney TF. CT guided biopsy. Cleve Clin Q 1977;44:27-33 https://doi.org/10.3949/ccjm.44.1.27
- Kinoshita F, Kato T, Sugiura K, Nishimura M, Kinoshita T, Hashimoto M, et al. CT-guided transthoracic needle biopsy using a puncture site-down positioning technique. AJR Am J Roentgenol 2006;187:926-932 https://doi.org/10.2214/AJR.05.0226
- Ohno Y, Hatabu H, Takenaka D, Imai M, Ohbayashi C, Sugimura K. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules. Eur J Radiol 2004;51:160-168 https://doi.org/10.1016/S0720-048X(03)00216-X
- Carlson SK, Felmlee JP, Bender CE, Ehman RL, Classic KL, Hoskin TL, et al. CT fluoroscopy-guided biopsy of the lung or upper abdomen with a breath-hold monitoring and feedback system: a prospective randomized controlled clinical trial. Radiology 2005;237:701-708 https://doi.org/10.1148/radiol.2372041323
- Heck SL, Blom P, Berstad A. Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses. Eur Radiol 2006;16:1387-1392 https://doi.org/10.1007/s00330-006-0152-2
- Irie T, Kajitani M, Matsueda K, Arai Y, Inaba Y, Kujiraoka Y, et al. Biopsy of lung nodules with use of I-I device under intermittent CT fluoroscopic guidance: preliminary clinical study. J Vasc Interv Radiol 2001;12:215-219 https://doi.org/10.1016/S1051-0443(07)61828-4
- Carlson SK, Bender CE, Classic KL, Zink FE, Quam JP, Ward EM, et al. Benefi ts and safety of CT fluoroscopy in interventional radiologic procedures. Radiology 2001;219:515-520 https://doi.org/10.1148/radiology.219.2.r01ma41515
- Froelich JJ, Ishaque N, Regn J, Saar B, Walthers EM, Klose KJ. Guidance of percutaneous pulmonary biopsies with real-time CT fluoroscopy. Eur J Radiol 2002;42:74-79 https://doi.org/10.1016/S0720-048X(01)00391-6
- Gianfelice D, Lepanto L, Perreault P, Chartrand-Lefebvre C, Milette PC. Value of CT fluoroscopy for percutaneous biopsy procedures. J Vasc Interv Radiol 2000;11:879-884 https://doi.org/10.1016/S1051-0443(07)61805-3
- Yamagami T, Iida S, Kato T, Tanaka O, Toda S, Kato D, et al. Usefulness of new automated cutting needle for tissue-core biopsy of lung nodules under CT fluoroscopic guidance. Chest 2003;124:147-154 https://doi.org/10.1378/chest.124.1.147
- Tsukada H, Satou T, Iwashima A, Souma T. Diagnostic accuracy of CT-guided automated needle biopsy of lung nodules. AJR Am J Roentgenol 2000;175:239-243 https://doi.org/10.2214/ajr.175.1.1750239
- Bladt O, De Wever W. Additional value of CT-fluoroscopic biopsy of pulmonary lesions: a retrospective study of 69 patients. JBR-BTR 2006;89:298-302
- Li H, Boiselle PM, Shepard JO, Trotman-Dickenson B, McLoud TC. Diagnostic accuracy and safety of CT-guided percutaneous needle aspiration biopsy of the lung: comparison of small and large pulmonary nodules. AJR Am J Roentgenol 1996;167:105-109 https://doi.org/10.2214/ajr.167.1.8659351
- Khouri NF, Stitik FP, Erozan YS, Gupta PK, Kim WS, Scott WW Jr, et al. Transthoracic needle aspiration biopsy of benign and malignant lung lesions. AJR Am J Roentgenol 1985;144:281-288 https://doi.org/10.2214/ajr.144.2.281
- Sagel SS, Ferguson TB, Forrest JV, Roper CL, Weldon CS, Clark RE. Percutaneous transthoracic aspiration needle biopsy. Ann Thorac Surg 1978;26:399-405 https://doi.org/10.1016/S0003-4975(10)62917-7
- Kurban LA, Gomersall L, Weir J, Wade P. Fluoroscopy-guided percutaneous lung biopsy: a valuable alternative to computed tomography. Acta Radiol 2008;49:876-882 https://doi.org/10.1080/02841850802225893
- Teeuwisse WM, Geleijns J, Broerse JJ, Obermann WR, van Persijn van Meerten EL. Patient and staff dose during CT guided biopsy, drainage and coagulation. Br J Radiol 2001;74:720-726 https://doi.org/10.1259/bjr.74.884.740720
- Manhire A, Charig M, Clelland C, Gleeson F, Miller R, Moss H, et al. Guidelines for radiologically guided lung biopsy. Thorax 2003;58:920-936 https://doi.org/10.1136/thorax.58.11.920
- Khan MF, Straub R, Moghaddam SR, Maataoui A, Gurung J, Wagner TO, et al. Variables affecting the risk of pneumothorax and intrapulmonal hemorrhage in CT-guided transthoracic biopsy. Eur Radiol 2008;18:1356-1363 https://doi.org/10.1007/s00330-008-0893-1
피인용 문헌
- Clinical Value of CT-Guided Needle Biopsy for Retroperitoneal Lesions vol.12, pp.3, 2011, https://doi.org/10.3348/kjr.2011.12.3.351
- Detection of pulmonary nodules by C-arm CT using a phantom lung: comparison with CT vol.52, pp.9, 2011, https://doi.org/10.1258/ar.2011.110187
- New Statistical Method to Analyze Three-Dimensional Landmark Configurations Obtained with Cone-Beam CT: Basic Features and Clinical Application for Rapid Maxillary Expansion vol.13, pp.2, 2011, https://doi.org/10.3348/kjr.2012.13.2.126
- CT-Guided Core Needle Biopsy of Deep Suprahyoid Head and Neck Lesions vol.14, pp.2, 2011, https://doi.org/10.3348/kjr.2013.14.2.299
- Constrained reconstructions for 4D intervention guidance vol.58, pp.10, 2013, https://doi.org/10.1088/0031-9155/58/10/3283
- Radiation Exposure of Patients by Cone Beam CT during Endobronchial Navigation - A Phantom Study vol.5, pp.3, 2014, https://doi.org/10.7150/jca.8395
- Cone Beam Computertomography (CBCT) in Interventional Chest Medicine - High Feasibility for Endobronchial Realtime Navigation vol.5, pp.3, 2014, https://doi.org/10.7150/jca.8834
- C-Arm Cone-Beam CT Virtual Navigation-Guided Percutaneous Mediastinal Mass Biopsy: Diagnostic Accuracy and Complications vol.25, pp.12, 2011, https://doi.org/10.1007/s00330-015-3762-8
- Role of C-Arm Cone-Beam CT in Chemoembolization for Hepatocellular Carcinoma vol.16, pp.1, 2015, https://doi.org/10.3348/kjr.2015.16.1.114
- Percutaneous Transthoracic Lung Biopsy: Comparison Between C-Arm Cone-Beam CT and Conventional CT Guidance vol.8, pp.4, 2015, https://doi.org/10.1016/j.tranon.2015.04.006
- 3D CACT-assisted Radiofrequency Ablation Following Transarterial Chemoembolization for Hepatocellular Carcinoma: Early Experience vol.16, pp.17, 2011, https://doi.org/10.7314/apjcp.2015.16.17.7897
- Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules vol.26, pp.2, 2016, https://doi.org/10.1007/s00330-015-3861-6
- Flat detector cone-beam CT-guided percutaneous needle biopsy of mediastinal lesions: preliminary experience vol.121, pp.10, 2016, https://doi.org/10.1007/s11547-016-0660-3
- Does the Reporting Quality of Diagnostic Test Accuracy Studies, as Defined by STARD 2015, Affect Citation? vol.17, pp.5, 2016, https://doi.org/10.3348/kjr.2016.17.5.706
- Flat detector C-arm CT-guidance system in performing percutaneous transthoracic needle biopsy of small (≤3 cm) pulmonary lesions vol.57, pp.6, 2011, https://doi.org/10.1177/0284185115603419
- Real-time respiratory phase matching between 2D fluoroscopic images and 3D CT images for precise percutaneous lung biopsy vol.44, pp.11, 2011, https://doi.org/10.1002/mp.12524
- A Systematic Review and Meta-Analysis of C-Arm Cone-Beam CT-Guided Percutaneous Transthoracic Needle Biopsy of Lung Nodules vol.82, pp.None, 2017, https://doi.org/10.12659/pjr.899626
- Cone-Beam CT Virtual Navigation-Guided Percutaneous Needle Biopsy of Suspicious Pleural Metastasis: A Pilot Study vol.19, pp.5, 2011, https://doi.org/10.3348/kjr.2018.19.5.872
- Diagnostic Performance of Core Needle Biopsy and Fine Needle Aspiration Separately or Together in the Diagnosis of Intrathoracic Lesions Under C-arm Guidance vol.102, pp.1, 2011, https://doi.org/10.5334/jbsr.1615