In the present work, a new freeze protection method has been proposed for a natural circulation system of solar water heater. Though electrothermal wire is popularly used for the purpose, there are freezing troubles by wire cut-off and excessive electric power consumption. In the experimental device, hot water in a storage tank was circulated by a small pump and used to heat the outdoor pipes if the cold water pipe surface temperature falls lower than a set point. As a result, It was observed that there was no hot water waste while the solar water heating system operated without freeze and burst.

키워드

참고문헌

  1. KEMCO, 2008, Solar Energy, BooksHill.
  2. Kim, S. S. and Hong, H., 2008, Measures and proposal for Korean solar water heating system, Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 20, No. 9, pp. 631-636.
  3. Duffie, J. A. and Beckman, W. A., 1991, Solar Engineering of Thermal Processes 2nd ed., Joha Wiley & Sons, p. 489.
  4. Kim, J. H., Hong, H., Chung, J. D., 2011, Verification experiment on freeze protection for solar hot water system, Korean J. of Air-Conditioning and Refrigeration Engineering, Vol. 23, No. 5, pp. 327-333. https://doi.org/10.6110/KJACR.2011.23.5.327

피인용 문헌

  1. FREEZE PROTECTION METHOD USING HOT WATER FOR PASSIVE SOLAR WATER HEATING SYSTEM vol.20, pp.04, 2012, https://doi.org/10.1142/S2010132512500216