Experimental Study on Bond Strength of Deformed Bars in Artificial Lightweight Aggregate Concrete

경량콘크리트의 부착특성에 대한 실험적 연구

  • Received : 2010.07.26
  • Accepted : 2010.09.29
  • Published : 2011.02.28

Abstract

For reinforced concrete members, the bond strength is one of the important factors between two materials: concrete and reinforcing element. This study concerns the bond strength of deformed bars in artificial lightweight aggregate concrete by pull-out test. 144 cubic specimens were manufactured for the test. concrete compressive strength, size of deformed bar and embedment lengths were considered as variables in this study. Normal concrete with W/C ratio 50% specimens were tested for the comparison. Test results included the bond stress-slip responses and modes of failure. Bond strength increased with an increase of compressive strength of concrete according to W/C ratio. The equation of bond stress of polymer-modified lightweight aggregate concrete were proposed by regression analysis based on the result.

철근 콘크리트 부재에서 부착강도는 콘크리트와 보강근 사이에 중요한 요소 중 하나이다. 본 실험에서는 인공경량골재를 사용한 경량콘크리트와 이형철근의 부착강도의 특성을 확인하기 위하여 인발실험을 수행하였다. 콘크리트의 압축강도, 이형철근의 직경과 묻힘길이를 변수로 하는 144개의 인발실험 시험체가 사용되었다. 보통콘크리트와의 비교를 위하여 물/시멘트 비 50%의 보통콘크리트의 인발실험을 수행하였으며, 실험을 통해서 부착응력-미끌림 관계와 파괴형상을 평가하였다. 물/시멘트 비에 따른 콘크리트의 압축강도가 증가할수록 부착강도는 증가하였다. 또한 인발실험을 토대로 회귀분석을 실시하여 경량 콘크리트의 부착응력에 대한 산정식을 제안하였다.

Keywords

References

  1. 권기주 (2010) 화력발전 부산물의 콘크리트에의 활용, 대한건축학회, 54(2), pp.46-49.
  2. 김현식, 최명신, 안종문, 이광수, 신성우 (1998) 고강도경량 콘크리트에 매립된 이형철근의 부착특성, 대한건축학회논문집, 18(1), pp.693-700.
  3. 문경주, 이철웅, 박원춘, 소양섭 (2005) 무기계 산업폐기물을 이용한 비소성 시멘트 콘크리트의 철근 인발 부착 특성, 대한건축학회 학술발표대회 논문집, 25(1), pp.73-76.
  4. 이동운, 김영수 (2006) 바텀애시를 잔골재로 부분 치환한 콘크 리트의 강도특성에 관한 연구, 대한건축학회논문집, 22(6), pp.79-80.
  5. 이종호, 김재환, 김용로, 강석표, 최세진, 김무한 (2002) 물 시멘트비에 따른 바텀애시를 사용한 콘크리트의 특성에 관 한 실험적 연구, 한국건축시공학회 학술발표대회, 한국건축시공학회, pp.57-60.
  6. 최동욱, 하상수, 이창호 (2007) 인발실험에 의한 GFRP 보강근의 정착길이 제안, 한국콘크리트학회, 19(3), pp.323-331
  7. 최세진, 김무한 (2009) 석탄회 종류에 따른 석탄회를 대량 사 용한 콘크리트의 내구특성에 관한 연구, 한국건축시공학회논문집, 9(3), pp.73-78.
  8. 한국산업규격 (2005) KS F 2405 콘크리트의 압축강도 시험 방법, 한국표준협회, pp.16.
  9. 한병찬, 윤현도, 정수영 (2001) 석탄회 골재를 사용한 고강도 경량콘크리트 보의 휨거동, 대한건축학회논문집, 17(4), pp.37-44.
  10. ACI 408R-03 (2003) Bond and Development of Straight Reinforcing Bars in Tension, ACI Committee 408, pp.49.
  11. ASTM A 615/A 615M-04a (2004) Standard Specification for Deformed and Plane Carbon Steel Bars for Concrete Reinforcement, ASTM Committee A01, pp.6.
  12. ASTM C 234-91a (1991) Standard Test Method for Comparing Concretes on the Basis of the Bond Developed sith Reinforcing Steel, ASTM Committee C-9, pp.5.
  13. Darwin, D., McCabe, S.L., Idun, E.K., Schoenekase, S.P. (1992) Development Length Criteria: Bars not Confined by Transverse Reinforcement, ACI Structural Journal, 89(6), pp.709-720.
  14. Hossain, K.M.A. (2008) Bond Characteristics of Plain and Deformed Bars in Lightweight Pumice Concrete, Construction and Building Materials, 22(7), pp.1491-1499. https://doi.org/10.1016/j.conbuildmat.2007.03.025
  15. Lee, J.Y., Kim, T.Y., Kim, T.J., Yi C.K., Park, J.S., You, Y.C., Park, Y.H. (2008) Interfacial Bond Strength of Glass Fiber Reinforced Polymer Bars in High-Strength Concrete, Composites Part B: Engineering, 39(2), pp.258-270. https://doi.org/10.1016/j.compositesb.2007.03.008
  16. Okelo, R., Yuan, R.L. (2005) Bond Strength of Fiber Reinforced Polymer Rebars in Normal Strength Concrete, Journal of Composites for Construction, 9(3), pp.203-213. https://doi.org/10.1061/(ASCE)1090-0268(2005)9:3(203)
  17. Orangun, C.O., Jirsa, J.O., Breen, J.E. (1977) A Reevaluation of Test Data on Development Length and Splices, ACI Structural Journal, 74(3), pp.114 -122.
  18. Qiao, X.C., Ng, B.R., Tyrer, M., Poon, C.S., Cheeseman, C.R. (2008) Production of Lightweight Concrete using Incinerator Bottom ash, Construction and Building Materials, 22(4), pp.473-474. https://doi.org/10.1016/j.conbuildmat.2006.11.013
  19. Xiao, J., Falkner, H. (2007) Bond Behaviour Between Recycled Aggregate Concrete and Steel Rebars, Construction and Building Materials, 21(2), pp.395 -401. https://doi.org/10.1016/j.conbuildmat.2005.08.008
  20. Zuo, J., Darwin, D. (2000) Splice Strength of Conventional and High Relative rib Area Bars in Normal and High-Strength Concrete, ACI Structural Journal, 97(4), pp.630-641.