참고문헌
- Branemark PI, Adell R, Breine U, Hansson BO, Lindstrom J, Ohlsson A. Intra-osseous anchorage of dental prostheses. I. Experimental studies. Scand J Plast Reconstr Surg 1969;3:81- 100. https://doi.org/10.3109/02844316909036699
- Higuchi KW, Folmer T, Kultje C. Implant survival rates in partially edentulous patients: A 3-year prospective multicenter study. J Oral Maxillofac Surg 1995;53:264-268. https://doi.org/10.1016/0278-2391(95)90222-8
- Mazzocchi A, Passi L, Moretti R. Retrospective analysis of 736 implants inserted without antibiotic therapy. J Oral Maxillofac Surg 2007;65:2321-2323 https://doi.org/10.1016/j.joms.2007.06.620
- Li W, Chow J, Hui E, Lee PKH, Cjow R. Resprospective study on immediate functional loading of edentulous maxillas and mandibles with 690 implants, up to 71 months of follow-up. J Oral Maxillofac Surg 2009;67:2653-2662 https://doi.org/10.1016/j.joms.2009.07.015
- Buser D, Schenk RK, Steinemann S, Fiorellini JP, Fox CH, Stich H. Influence of surface characteristics on bone integration of titanium implants. A histomorphometric study in miniature pigs. J Biomed Mater Res 1991;25:889-902. https://doi.org/10.1002/jbm.820250708
- Pye AD, Lockhart DEA, Dawson MP, Murray CA, Smith AJ. A review of dental implants and infection. J of Hospital Infection 2009;72:104-110 https://doi.org/10.1016/j.jhin.2009.02.010
- Bashutski JD, D`Silva NJ, Wang HL. Implant compression necrosis: Current understanding and case report. J Periodontol 2009;80:700-704. https://doi.org/10.1902/jop.2009.080581
- Quirynen M, De Soete M, Van Steenberghe D. Infectious risks for oral implants: A review of the literature. Clin Oral Implants Res 2002;13:1-19. https://doi.org/10.1034/j.1600-0501.2002.130101.x
- Branemark PI, Zarb GA, Albrektsson T. Tissue integrated prostheses: Osseointegration in clinical dentistry. Chicago, IL: Quintessence 1985:129-143.
- Eriksson R, Albrektsson T. Temperature thresholds for heat induced bone tissue injury: A vital-microscopic study in the rabbit. J Prosthet Dent 1983;50:101-107. https://doi.org/10.1016/0022-3913(83)90174-9
- Eriksson R, Albrektsson T. The effect of heat on bone regeneration: An experimental study in the rabbit using the bone growth chamber. J Oral Maxillofac Surg 1984;42:705-711. https://doi.org/10.1016/0278-2391(84)90417-8
- Sharawy M, Misch CE, Weller N, Tehemer S. Heat generation during implant drilling: The significance of motor speed. J Oral Maxillofac Surg 2002;60:1160-1169. https://doi.org/10.1053/joms.2002.34992
- Chacon GE, Bower DL, Larsen PR, McGlumphy EA, Beck FM. Heat production by 3 implant drill systems after repeated drilling and sterilization. J Oral Maxillofac Surg 2006; 64:265-269. https://doi.org/10.1016/j.joms.2005.10.011
- Eriksson R, Adell R. Temperatures during for the placement of implants using the osseointegration technique. J Oral Maxillofac Surg 1986;44:4-7. https://doi.org/10.1016/0278-2391(86)90006-6
- Cordioli G, Majzoub Z. Heat generation during implant site preparation: An in vitro study. Int J Oral Maxillofac Implants 1997;12:186-193.
- Ercoli C, Funkenbusch PD, Lee HJ, Moss ME, Graser GN. The influence of drill wear on cutting efficiency and heat production during osteotomy preparation for dental implants: A study of drill durability. Int J Oral Maxillofac Implants 2004;19:335-349.
- Queiroz TP, Souza FA, Okamoto R, Margonar R, Pereira-Filho VA, Garcia Junior IR et al. Evaluation of immediate bone-cell viability and of drill wear after implant osteotomies: Immunohistochemistry and scanning electron microscopy analysis. J Oral Maxillofac Surg 2008;66:1233-1240. https://doi.org/10.1016/j.joms.2007.12.037
- Yoshida K, Uoshima K, Oda K, Maeda T. Influence of heat stress to matrix on bone formation. Clin. Oral Impl. Res. 2009;20:782-790. https://doi.org/10.1111/j.1600-0501.2009.01654.x
- Cem Sener B, Dergin G, Gursoy B, Kelesoglu E, Slih I. Effects of irrigation temperature on heat control in vitro at different drilling depths. Clin. Oral Impl. Res. 2009;20:294-298. https://doi.org/10.1111/j.1600-0501.2008.01643.x
- Misir AF, Sumer M, Yenisey M, Ergioglu E. Effect of surgical drill guide on heat generated from implant drilling. J Oral Maxillofac Surg 2009;67:2663-2668. https://doi.org/10.1016/j.joms.2009.07.056
- Piattelli A, Piattelli M, Mangano C, Scarano A. A histologic evaluation of eight cases of failed dental implants: Is bone overheating the most probable cause? Biomaterials 1998;19:683-690. https://doi.org/10.1016/S0142-9612(97)00172-5
- Piattelli A, Scarano A, Balleri P, Favero GA. Clinical and histologic evaluation of an active" Implant Periapical Lesion": A case report. Int J Oral Maxiilofac Implants 1998;13:713-716.
- Penarrocha-Diage M, Boronat-Lopez A, Garcia-Mira B. Inflammatory implant periapical lesion: Etiology, diagnosis, and treatment - presentation of 7 cases. J Oral Maxillofac Surg 2009;67:168-173. https://doi.org/10.1016/j.joms.2007.12.022
- Sverzut AT, Vitti Stabile GA, Moraes M, Mazzonetto R, Fernandes Moreira RW. The influence of tobacco on early dental implant failure. J Oral Maxillofac Surg 2008;66:1004-1009. https://doi.org/10.1016/j.joms.2008.01.032
- Piattelli A, Scarano A, Piattelli M. Abscess formation around the apex of a maxillary root form implant: Cinical and microscopical aspects. A case report. J Periodontol 1995;66:899-903. https://doi.org/10.1902/jop.1995.66.10.899
- Alsaadi G, Quirynen M, Komarek A, van Steenberghe D. Impact of local and systemic factors on the incidence of oral implant failures, up to abutment connection. J Clin Periodontol. 2007;34: 610-617. https://doi.org/10.1111/j.1600-051X.2007.01077.x
- Pommer B, Frantal S, Willer J, Posch M, Watzek G, Tepper G.. Impact of dental implant length on early failure rates: a metaanalysis of observational studies. J Clin Periodontol. 2011; 38:856-863. https://doi.org/10.1111/j.1600-051X.2011.01750.x
- Park JC, Ha SR, Kim SM, Kim MJ, Lee JB, Lee JH. A randomized clinical 1-year trial comparing two types of non-submerged dental implants. Clin Oral Implants Res. 2010;21:228-236. https://doi.org/10.1111/j.1600-0501.2009.01828.x
- Matthews LS, Hirsch C. Temperature measured in human cortical bone when drilling. J Bone joint Surg[Am] 1972;54:297-308. https://doi.org/10.2106/00004623-197254020-00008
- Rhinelander F, Nelson CL, Steward RD, Steward CL. Experimental reaming of the proximal femur and acrylic cement implantation. Vascular and histologic effects. Clin Orthop 1979;141:74-89.
- Turkyilmaz I, Sennerby L, McGlumphy EA, Tozum TF. Biomechanical aspects of primary implant stability: A human cadaver study. Clin Implant Dent Relat Res 2009;11:113-119. https://doi.org/10.1111/j.1708-8208.2008.00097.x
- Tehemar SH. Factors affecting heat generation during implant site preparation: A review of biologic observations and future considerations. Int J Oral Maxillofac Implants 1999;14:127-136.
- Lundskog J. Heat and bone tissue. An experimental investigation of the thermal properties of bone and threshold levels for thermal injury. Scand J Plast Reconstr Surg 1972;9:1-80.
- Lavelle C, Wedgwood D. Effect of internal irrigation on frictional heat generated from bone drilling. J Oral Surg 1980;38:499- 503.
- Sutter F, Krekeler G, Schwammberger AE, Sutter FJ. Atraumatic surgical technique and implant bed preparation. Quintessence Int 1992;23:811-816.
피인용 문헌
- Temperature Values Variability in Piezoelectric Implant Site Preparation: Differences between Cortical and Corticocancellous Bovine Bone vol.2016, pp.None, 2011, https://doi.org/10.1155/2016/6473680
- Application of finite element analysis to evaluate optimal parameters for bone/tooth drilling to avoid thermal necrosis vol.8, pp.1, 2011, https://doi.org/10.1080/23311916.2021.1876582
- Thermal exposure of implant osteotomies and its impact on osseointegration—A preclinical in vivo study vol.32, pp.6, 2011, https://doi.org/10.1111/clr.13729