DOI QR코드

DOI QR Code

Performance improvement of 2 stage GM-type pulse tube Cryocooler for cryopump

  • Park, Seong-Je (Energy Systems Research Division, Korea Institute of Machinery & Materials) ;
  • Koh, Deuk-Yong (Energy Systems Research Division, Korea Institute of Machinery & Materials) ;
  • Suh, Jeong-Kyoon (Energy Systems Research Division, Korea Institute of Machinery & Materials)
  • Received : 2011.10.31
  • Accepted : 2011.11.24
  • Published : 2011.11.30

Abstract

This paper describes experimental study and performance improvement of 2 stage Gifford-McMahon (G-M) type pulse tube cryocooler for cryopump. The objective of this study is to improve the efficiency of 2 stage pulse tube cryocooler for substituting 2 stage G-M cryocooler used in cryopump. The target cooling capacities are 5 W at 20 K and 35 W at 80 K for the $1^{st}$ and the $2^{nd}$ stage, respectively. These values are good cooling capacities for vacuum level in medium size ICP 200 cryopump. Design of the 2 stage pulse tube cryocooler is conducted by FZKPTR(Forschungs Zentrum Karlsruhe Pulse Tube Refrigerator) program. In order to improve the performance of 2 stage pulse tube cryocooler, U-type pulse tube cryocooler is fabricated and connecting tubes are minimized for reducing dead volumes and pressure losses. Also, to get larger capacities, orifice valves and double inlet valves are optimized and the compressor of 6 kW is used. On the latest unit, the lowest temperatures of 2 stage pulse tube cryocooler are 42 K ($1^{st}$ stage) and 8.3 K ($2^{nd}$ stage) and the cooling capacities are 40 W at 82.9 K ($1^{st}$ stage) and 10 W at 20.5 K ($2^{nd}$ stage) with 6.0 kW of compressor input power. This pulse tube cryocooler is suited for commercial medium size cryopump. In performance test of cryopump with 2 stage pulse tube cryocooler, pumping speed for gaseous nitrogen is 4,300 L/s and the ultimate vacuum pressure is $7.5{\times}10^{-10}$ mbar.

Keywords

References

  1. S.G.Gilankar and P.K.Kush, "Performance of indigeniosly developed closed cycle refrigerator based cryopump," Proc. National Symp. on vacuum science & technology and its application to plasmas, pp. 157-160, 2005.
  2. C. Wang, "Efficient 10 K Pulse Tube Cryocoolers," Cryocoolers 13, Plenum Publishing Corp., New York, pp. 133-140, 2005.
  3. W.W. Burt and C.K. Chan, "New mid-size high efficiency pulse tube coolers," Cryocoolers 9, Plenum Publishing Corp., New York, pp. 173-182, 1997.
  4. W.E. Gifford and R.C. Longsworth, "Pulse-tube refrigeration," Trans. ASME: J Eng Ind Series B 86, pp.264-268, 1964. https://doi.org/10.1115/1.3670530
  5. E.I. Mikulin et al., "Low temperature expansion pulse tubes," Adv. Cryo. Eng. Vol. 29, pp. 629, 1984.
  6. Radebaugh, R., Zimmerman, J., Smith, D. R., and Louie, B., "A comparison of three types of pulse tube refrigerators: new methods for reaching 60K," Adv. Cryogenic Engineering, vol. 31, pp. 779, 1986.
  7. S.W. Zhu, P.Y. Wu and Z.Q. Chen, "Double inlet pulse tube refrigerators: an important improvement," Cryogenics 30, pp. 514-520, 1990. https://doi.org/10.1016/0011-2275(90)90051-D
  8. A. Ravex, I. Charles, L. Duband and J.M. Poncet, "Pulse tube development at CEA/SBT," Proc. of the IIR Conf., Sidney, Sept. 1999.
  9. S.G.Gilankar and P.K.Kush, "Performance of indigeniosly developed closed cycle refrigerator based cryopump," Proc. National Symp. on vacuum science & technology and its application to plasmas, pp. 157-160, 2005.
  10. A.Hofmann, "Instructions for Using the Numeric Code FZKPTR for the design of Pulse Tube Cooler," Institute fur Technische Physik, 출처, 2003.
  11. S.J.Park, etc., "Experimental research on 2 stage GM-type pulse tube refrigerator for cryopump," Superconductivity and Cryogenics, Vol. 12, pp. 29-33, 2010.
  12. Re H.B.Kim, J.H.Park, "Research on fast cool-down of orifice pulse tube refrigerator by controlling orifice valve opening," Superconductivity and Cryogenics, vol. 12, pp. 36-40, 2010.