Reduction in Seismic Response of URANUS Liquid Metal Reactor by Using Three-Dimensional Seismic Isolator

3차원 면진장치를 이용한 URANUS 액체금속로의 지진응답감소

  • 이국희 (고려대학교 기계공학과 대학원) ;
  • 김윤재 (고려대학교 기계공학과) ;
  • 류강묵 (고려대학교 기계공학과 대학원) ;
  • 황일순 (서울대학교 원자핵공학과) ;
  • 유봉 (벨기에 원자력연구원)
  • Received : 2011.07.06
  • Accepted : 2011.07.22
  • Published : 2011.09.01

Abstract

URANUS (Ubiquitous, Robust, Accident-forgiving, Non-proliferating, Ultra-lasting and Sustainer) has been developed with 35MWe (100MWth) operating without primary coolant pump, capitalizing on natural circulation capability of lead-bismuth eutectic (LBE) for long-life small and robust power units. To ensure the structural integrity, the large safety margin against Safe Shutdown Earthquake, 0.3g, and furthermore the cost effectiveness for URANUS, three-dimensional seismic base isolation design has been developed. The analytical model has been developed and seismic time history analyses have been carried out. The advantage for using three-dimensional seismic base isolation for URANUS has been discussed.

Keywords