DOI QR코드

DOI QR Code

Implementation of a Full Field Digital Mammography

디지털 유방X-선촬영기의 구현

  • Roh, Young-Sup (Department of u-City and Convergence Technologies, Seoul University of Venture and Information) ;
  • Yeo, Se-Yeon (Quality Control Team, Medi-Future, Inc.) ;
  • Lee, Jae-Jun (Image Technology of R&D Center, Medi-Future, Inc.) ;
  • Sohn, Surg-Won (Graduate School of Venture, Hoseo University)
  • 노영섭 (서울벤처정보대학원대학교 유시티.융합기술경영) ;
  • 여세연 (메디퓨처(주) QM팀) ;
  • 이재준 (메디퓨처(주) 연구소 영상기술) ;
  • 손석원 (호서대학교 벤처전문대학원)
  • Received : 2011.07.04
  • Accepted : 2011.10.06
  • Published : 2011.10.31

Abstract

The technologies of image acquisition, display, and storage of the breast have been developed in their specialized fields in recent years. The image acquisition system is a device that absorbs and stores images after examining breast tissue using X-ray. Due to the specificity and sensitivity of imaging, the early detection of breast cancer is feasible. In this paper, the current technologies for digital mammography are reviewed, and we propose a digital mammography and evaluate the performance of the implemented system.

최근 디지털 유방촬영술 분야에서 영상의 획득장치, 표시장치, 저장장치는 각각 별도의 분야로 발전하고 있다. 영상획득장치는 유방을 통과한 X-선을 흡수 포착하여 영상으로 저장하는 장치인데, 이를 이용하여 촬영된 영상은 여러 가지의 영상처리기술을 이용하여 진단이 가능하기 때문에 조기에 병변을 발견할 수 있다. 본 논문에서는 지금까지의 디지털 유방촬영술의 기술에 대하여 알아보고 구현된 디지털 유방X-선촬영기의 성능을 분석한다.

Keywords

References

  1. Pisano ED, Yaffe MJ, Kuzmiak CM. Digital mammography, pp15-26, Lippincott Williams & Willkins, Oct. 2003.
  2. Andrew P. Smith, "Fundamentals of Digital Mammography: Physics, Technology and Practical Considerations," Radiol Manage, vol. 25(5), pp18-24,26-31, Sep. 2003.
  3. Etta D. Pisano, Martin J. Yaffe, "Digital Mamm ography," Radiology, vol. 234, pp353-362, Feb. 2005. https://doi.org/10.1148/radiol.2342030897
  4. Nariya Cho, Joo Hee Cha, Woo Kyung Moon, "Digital Mammography," The journal of the Korean society of radiology, vol.52, pp225-231, 2005. https://doi.org/10.3348/jkrs.2005.52.4.225
  5. Paul S. Rezentes, Adelaide de Almeida, Gary T. Barnes, Mammography Grid Performance, Radiology, vol. 210, pp227-232, Jan. 1999 https://doi.org/10.1148/radiology.210.1.r99dc35227
  6. Y. H. Chu, E. J. Lee, K. S. Lee, D. Y. Ha, " Analysis of the average glandular dose on the Digital mammography AOP mode," Internal conference on the Korean Radiological Techn ologists Association, pp66-67, Apr. 2009.
  7. IEC, "IEC 62220-1-2, Medical electrical equipment-Characteristics of digital X-ray imaging devices, Part 1-2: Determination of the detective quantum efficiency-Detectors used in mammography," IEC, Jun. 2007.
  8. ANRAD Corporation, "Medi-Future SMAM det ector specification," 2007.
  9. Rafael G-M, Rafael L, Rafael A, "Study of DQE dependence with beam quality on GE Essential mammography flat panel," Journal of applied clinical medical physics, vol.12 no.1, pp207-217, 2011.