References
- T. H. P. Chang, D. P. Kern, and M. A. McCord, "Electron optical performance of a scanning tunneling microscope controlled field emission microlens system," J. Vac. Sci. Technol. B 7, 1855-1861 (1989). https://doi.org/10.1116/1.584680
- E. Kratschmer, H. S. Kim, M. G. R. Thomson, K. Y. Lee, S. A. Rishton, M. L. Yu, and T. H. P. Chang, "Sub‐40 nm resolution 1 keV scanning tunneling microscope field‐emission microcolumn," J. Vac. Sci. Technol. B 12, 3503-3507 (1994). https://doi.org/10.1116/1.587459
- Y. C. Kim, H. S. Kim, S. J. Ahn, H. W. Kim, T. Yoshimoto, and D. W. Kim, "Advanced microcolumn operation for low-energy electron-beam lithography," J. Korean Phys. Soc. 49, 1428-1433 (2006).
- D. A. Crewe, D. C. Perng, S. E. Shoaf, and A. D. Feinerman, "Micromachined electrostatic electron source," J. Vac. Sci. Technol. B 10, 2754-2758 (1992). https://doi.org/10.1116/1.585996
- T. H. P. Chang, M. G. R. Thomson, E. Kratschmer, H. S. Kim, M. L. Yu, K. Y. Lee, S. A. Rishton, B. W. Hussey, and S. Zolgharnain, "Electron‐beam microcolumns for lithography and related applications," J. Vac. Sci. Technol. B 14, 3774-3781 (1996). https://doi.org/10.1116/1.588666
- H. S. Kim, D. W. Kim, S. J. Ahn, Y. C. Kim, S. S. Park, K. W. Park, N. W. Hwang, S. W. Jin, and S. Y. Bae, "Feasibility study of TFT-LCD array tester using low voltage micro-columns," Microelectron. Eng. 85, 782-786 (2008). https://doi.org/10.1016/j.mee.2007.12.042
- T. S. Oh, D. W. Kim, Y. C. Kim, S. Ahn, G. Lee, and H. S. Kim, "Inspection of open defects in a thin film transistorliquid crystal display panel by using a low-energy electron microcolumn," J. Vac. Sci. Technol. B 28, C6C69-C6C74 (2010). https://doi.org/10.1116/1.3502658
- T. S. Oh, D. W. Kim. S. Ahn, Y. C. Kim, S. J. Ahn, and H. S. Kim, "Optimization of electrostatic lens systems for low-energy scanning microcolumn applications," J. Vac. Sci. Technol. A 26, 1443-1449 (2008). https://doi.org/10.1116/1.2987949
- H. S. Kim, D. W. Kim, S. J. Ahn, Y. C. Kim, S. S. Park, S. K. Choi, and D. Y. Kim, "The assembly of a fully functional microcolumn and its STEM-Mode operation," J. Korean Phys. Soc. 43, 831-835 (2003).
- S. Ahn, D. W. Kim, H. S. Kim, J. Cho, and S. J. Ahn, "Fabrication of a miniaturized electron lens system and laser micro-machining condition for silicon membrane," Microelectron. Eng. 69, 57-64 (2003). https://doi.org/10.1016/S0167-9317(03)00229-6
- S. S. Park, D. W. Kim, S. Ahn, Y. C. Kim, S. K. Choi, D. Y. Kim, and H. S. Kim, "High-beam-current microcolumns with large apertures," Jpn. J. Appl. Phys. 43, 3986-3989 (2004). https://doi.org/10.1143/JJAP.43.3986
- E. Kratschmer, H. S. Kim, M. G. R. Thomson, Y. Lee, S. A. Rishton, M. L. Yu, and T. H. P. Chang, "An electronbeam microcolumn with improved resolution, beam current, and stability," J. Vac. Sci. Technol. B 13, 2498-2503 (1995).
- M. Mankos, K. Y. Lee, L. Muray, J. Spallas, Y. Hsu, C. Stebler, W. DeVore, E. Bullock, and T. H. P. Chang, "Optimization of microcolumn electron optics for high-current applications," J. Vac. Sci. Technol. B 18, 3057-3060 (2000). https://doi.org/10.1116/1.1321756
Cited by
- Forming a Fresnel Zone Lens: Effects of Photoresist on Digital-micromirror-device Maskless Lithography with Grayscale Exposure vol.16, pp.2, 2012, https://doi.org/10.3807/JOSK.2012.16.2.127