소공간 실험구의 차광과 통풍에 의한 기온저감 효과

Air Temperature Decreasing Effects by Shading and Ventilation at Micro-scale Experiment Plots

  • 투고 : 2010.09.02
  • 심사 : 2010.12.14
  • 발행 : 2010.12.31

초록

The purpose of this study was to analyze air temperature decreasing effects by shading and ventilation at micro-scale experiment plots, especially focused on the Wet Bulb Globe Temperature (WBGT) in outdoor spaces. To monitor the time-serial changes of Dry-bulb Temperature (DT), Globe Temperature (GT) and Relative Humidity (RH) in the wind blocking and shading conditions, Two hexahedral steel frames were established on the open grass field, the dimension of each frame was 1.5m(W)${\times}$1.5m(L)${\times}$1.5m(H). Four vertical side of one frame was covered by transparent polyethylene film to prevent wind passing through (Wind break plot; WP). The top side of the other frame was covered with shading curtain which intercept 95% of solar light and energy (Shading plot; SP). And, Another vertical steel frame without any treatment preventing ventilation and sunlight was set up, which represents natural conditions (Control plot; CP). The major findings were as follows; 1. The average globe temperature (GT) was highest at WP showing $50.94^{\circ}C$ and lowest at SP showing $34.58^{\circ}C$. The GT of natural condition (SP) was $42.31^{\circ}C$ locating the midst between WP and SP. The difference of GT of each plot was about $8-16^{\circ}C$, which means the ventilation and shading has significant effect on decreasing the temperature. 2. WP showed the highest average dry-bulb temperature (DT) of $38.41^{\circ}C$ which apparently differ from SP and CP showing $31.94^{\circ}C$ and $33.15^{\circ}C$ respectively. The DT of SP and CP were nearly the same. 3. The average relative humidity (RH) was lowest at WP showing 15.21%, but SP and CP had similar RH 28.79%, 28.02% respectively. 4. The average of calculated WBGT were the highest at the WP ($27.61^{\circ}C$) and the lowest at the SP ($23.64^{\circ}C$). The CP ($25.49^{\circ}C$) was in the middle of the others. As summery, compared with natural condition (CP), the wind blocking increased about $2.11^{\circ}C$ WBGT, but the shading decreased about $1.84^{\circ}C$ WBGT. So It can be apparently said that the open space with much shading trees, sheltering furnitures and well-delivered wind corridor can reduce useless and even harmful energy for human outdoor activity considerably in outdoor spaces.

키워드

참고문헌

  1. 김경태.이우성.정성관.박경훈. 2010. 친환경적 공간계획을 위한 도시의 열환경 분석. 한국지리정보학회지 13(1):142-155.
  2. 김수봉.김해동. 2002. 도시의 수목이 기온의 조절에 미치는 영향. 한국조경학회지 30(3):25-34.
  3. 김영환. 1995. 환경위생학실험. 동화기술:384-416.
  4. 노동부. 1997. 작업환경측정 및 정도관리규정. 노동부고시 제1997-58호.
  5. 노동부. 2009. 작업환경측정 및 정도관리규정. 노동부고시 제2009-78호.
  6. 백상훈.정응호. 2009. 위성영상의 시계열 분석을 통한 미기후변화 분석-대구시 달서구를 대상으로-. 한국지리정보학회지 12(2):34-43.
  7. 오규식․서안선․정승현. 2009. 열환경 개선을 위한 아파트주동배치계획. 한국환경복원기술학회지 12(2):83-94.
  8. 윤용한. 1999a. 녹지에 의한 기상환경개선 효과에 관한 실증적 연구. 건국자연과학연구지 10(2):191-210.
  9. 윤용한. 2004b. 도시녹지가 미기상조절에 미치는 실증적 연구. 한국환경생물학회 22(2):279-286.
  10. 이상화.이규석.정해연.김문성. 2009. 도시 공원 내 식생 수관에 의한 기온변화. 한국환경복원학회 12(1):44-51.
  11. 이춘석.류남형. 2010. 조경포장이 옥외공간의 온열쾌적성지수(WBGT)에 미치는 여향-통풀과 차광이 배제된 하절기 주간의 조건에서-. 한국조경학회지 38(2):1-8.
  12. 조현길.안태원. 1999a. 도시녹지에 의한 미기후 개선의 기능. 한국조경학회지 27(4):23-28.
  13. 조현길.안태원. 2006b. 도시 수목식재와 미기후 개선의 상관성 구명. 한국조경학회지 34(5):70-75.
  14. 조명희․조윤원․김성재. 2009. 도시복원사업의 열환경 변화 분석을 위한 ASTER 열적외 위성영상자료의 활용-청계천 복원사업을 사례로-. 한국지리정보학회지 12(1):73-80.
  15. 주민진.이춘석.류남형. 2004. 도심 녹음수의 체감온도지수(WBGT) 조절효과. 한국조경학회지 32(3):51-59.
  16. Fujisaki, K. 1995. Landscape Studies based on the Analysis of Micro Climate. J.JILA 58(5):320-321.
  17. Hiroyuki, Y. 2003. ヒ-トアイランド化が都市生活に及ぼす影響. 綠の讀本:13-17.
  18. Hough, M. 1984. City From and Nature Process. Von Nostrand Reinhold. 신용석.오구균 (역). 도시경관.생태론. 기문당 40-46.
  19. http://www.bom.gov.au/info/thermal_stress.
  20. http://www.kma.go.kr/weather/observation/past_cal.jsp?stn=192&yy2010.