참고문헌
- Greenhalgh RM, Brown LC, Kwong GP, Powell JT, Thompson SG; EVAR trial participants. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial. Lancet 2004;364:843-848 https://doi.org/10.1016/S0140-6736(04)16979-1
- Prinssen M, Verhoeven EL, Buth J, Cuypers PW, van Sambeek MR, Balm R, et al. A randomized trial comparing conventional and endovascular repair of abdominal aortic aneurysms. N Engl J Med 2004;351:1607-1618 https://doi.org/10.1056/NEJMoa042002
- Parodi JC, Palmaz JC, Barone HD. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms. Ann Vasc Surg 1991;5:491-499 https://doi.org/10.1007/BF02015271
- Buth J, van Marrewijk CJ, Harris PL, Hop WC, Riambau V, Laheij RJ; EUROSTSR Collaborators. Outcome of endovascular abdominal aortic aneurysm repair in patients with conditions considered unfit for an open procedure: a report on the EUROSTAR experience. J Vasc Surg 2002;35:211-221 https://doi.org/10.1067/mva.2002.121050
- Lobato AC, Quick RC, Vaughn PL, Rodriguez-Lopez J, Douglas M, Diethrich EB. Transrenal fixation of aortic endografts: intermediate follow-up of a single-center experience. J Endovasc Ther 2000;7:273-278 https://doi.org/10.1583/1545-1550(2000)007<0273:TFOAEI>2.3.CO;2
- Bove PG, Long GW, Zelenock GB, Bendick PJ, Khoury MD, Burr MO, et al. Transrenal fixation of aortic stent-grafts for the treatment of infrarenal aortic aneurysmal disease. J Vasc Surg 2000;32:697-703 https://doi.org/10.1067/mva.2000.110051
- Green RM. Patient selection for endovascular abdominal aortic aneurysm repair. J Am Coll Surg 2002;194:S67-S73 https://doi.org/10.1016/S1072-7515(01)01080-8
- Dillavou ED, Muluk SC, Rhee RY, Tzeng E, Woody JD, Gupta N, et al. Does hostile neck anatomy preclude successful endovascular aortic aneurysm repair? J Vasc Surg 2003;38:657-663 https://doi.org/10.1016/S0741-5214(03)00738-9
- Browne TF, Hartley D, Purchas S, Rosenberg M, Van Schie G, Lawrence-Brown M. A fenestrated covered suprarenal aortic stent. Eur J Vasc Endovasc Surg 1999;18:445-449 https://doi.org/10.1053/ejvs.1999.0924
- Faruqi RM, Chuter TA, Reilly LM, Sawhney R, Wall S, Canto C, et al. Endovascular repair of abdominal aortic aneurysm using a pararenal fenestrated stent-graft. J Endovasc Surg 1999;6:354-358 https://doi.org/10.1583/1074-6218(1999)006<0354:EROAAA>2.0.CO;2
- Stanley BM, Semmens JB, Lawrence-Brown MM, Goodman MA, Hartley DE. Fenestration in endovascular grafts for aortic aneurysm repair: new horizons for preserving blood flow in branch vessels. J Endovasc Ther 2001;8:16-24 https://doi.org/10.1583/1545-1550(2001)008<0016:FIEGFA>2.0.CO;2
- Anderson JL, Berce M, Hartley DE. Endoluminal aortic grafting with renal and superior mesenteric artery incorporation by graft fenestration. J Endovasc Ther 2001;8:3-15 https://doi.org/10.1583/1545-1550(2001)008<0003:EAGWRA>2.0.CO;2
- Sun Z, Mwipatayi BP, Semmens JB, Lawrence-Brown MM. Short to midterm outcomes of fenestrated endovascular grafts in the treatment of abdominal aortic aneurysms: a systematic review. J Endovasc Ther 2006;13:747-753 https://doi.org/10.1583/06-1919.1
- Semmens JB, Lawrence-Brown MM, Hartley DE, Allen YB, Green R, Nadkarni S. Outcomes of fenestrated endografts in the treatment of abdominal aortic aneurysm in Western Australia (1997-2004). J Endovasc Ther 2006;13:320-329 https://doi.org/10.1583/05-1686.1
- Sun Z, Allen YB, Nadkarni S, Knight R, Hartley DE, Lawrence-Brown MM. CT virtual intravascular endoscopy in the visualization of fenestrated stent-grafts. J Endovasc Ther 2008;15:42-51 https://doi.org/10.1583/07-2234.1
- Sun Z, Allen YB, Mwipatayi BP, Hartley DE, Lawrence-Brown MM. Multislice CT angiography in the follow-up of fenestrated endovascular grafts: effect of slice thickness on 2D and 3D visualization of the fenestration stents. J Endovasc Ther 2008;15:417-426 https://doi.org/10.1583/08-2432.1
- Richter GM, Palmaz JC, Noeldge G, Tio F. Relationship between blood flow, thrombus, and neointima in stents. J Vasc Interv Radiol 1999;10:598-604 https://doi.org/10.1016/S1051-0443(99)70090-4
- Beythien C, Gutensohn K, Bau J, Hamm CW, Kuhnl P, Meinertz T, et al. Influence of stent length and heparin coating on platelet activation: a flow cytometric analysis in a pulsed floating model. Thromb Res 1999;94:79-86 https://doi.org/10.1016/S0049-3848(98)00198-4
- Peacock J, Hankins S, Jones T, Lutz R. Flow instabilities induced by coronary artery stents: assessment with an in vitro pulse duplicator. J Biomech 1995;28:17-26 https://doi.org/10.1016/0021-9290(95)80003-4
- Sun Z, Winder RJ, Kelly BE, Ellis PK, Hirst DG. CT virtual intravascular endoscopy of abdominal aortic aneurysms treated with suprarenal endovascular stent grafting. Abdom Imaging 2003;28:580-587 https://doi.org/10.1007/s00261-002-0069-4
- Sun Z. 3D multislice CT angiography in post-aortic stent grafting: a pictorial essay. Korean J Radiol 2006;7:205-211 https://doi.org/10.3348/kjr.2006.7.3.205
- Sun Z, Mwipatayi BP, Allen YB, Hartley DE, Lawrence-Brown MM. Multislice CT angiography of fenestrated endovascular stent grafting for treating abdominal aortic aneurysms: a pictorial review of the 2D/3D visualizations. Korean J Radiol 2009;10:285-293 https://doi.org/10.3348/kjr.2009.10.3.285
- Frauenfelder T, Lotfey M, Boehm T, Wildermuth S. Computational fluid dynamics: hemodynamic changes in abdominal aortic aneurysm after stent-graft implantation. Cardiovasc Intervent Radiol 2006;29:613-623 https://doi.org/10.1007/s00270-005-0227-5
- Borghi A, Wood NB, Mohiaddin RH, Xu XY. Fluid-solid interaction simulation of flow and stress pattern in thoracoabdominal aneurysms: a patient-specific study. J Fluids Struct 2008;24:270-280 https://doi.org/10.1016/j.jfluidstructs.2007.08.005
- Li Z, Kleinstreuer C. Analysis of biomechanical factors affecting stent-graft migration in an abdominal aortic aneurysm model. J Biomech 2006;39:2264-2273 https://doi.org/10.1016/j.jbiomech.2005.07.010
- Chong CK, How TV. Flow patterns in an endovascular stentgraft for abdominal aortic aneurysm repair. J Biomech 2004;37:89-97 https://doi.org/10.1016/S0021-9290(03)00236-7
- Deplano V, Knapp Y, Bertrand E, Gaillard E. Flow behaviour in an asymmetric compliant experimental model for abdominal aortic aneurysm. J Biomech 2007;40:2406-2413 https://doi.org/10.1016/j.jbiomech.2006.11.017
- Fillinger MF, Raghavan ML, Marra SP, Cronenwett JL, Kennedy FE. In vivo analysis of mechanical wall stress and abdominal aortic aneurysm rupture risk. J Vasc Surg 2002;36:589-597 https://doi.org/10.1067/mva.2002.125478
- Li Z, Kleinstreuer C. Fluid-structure interaction effects on sacblood pressure and wall stress in a stented aneurysm. J Biomech Eng 2005;127:662-671 https://doi.org/10.1115/1.1934040
- Liffman K, Lawrence-Brown MM, Semmens JB, Sutalo ID, Bui A, White F, et al. Suprarenal fixation: effect on blood flow of an endoluminal stent wire across an arterial orifice. J Endovasc Ther 2003;10:260-274 https://doi.org/10.1583/1545-1550(2003)010<0260:SFEOBF>2.0.CO;2
- Carlier SG, van Damme LC, Blommerde CP, Wentzel JJ, van Langehove G, Verheye S, et al. Augmentation of wall shear stress inhibits neointimal hyperplasia after stent implantation: inhibition through reduction inflammation? Circulation 2003;107:2741-2746 https://doi.org/10.1161/01.CIR.0000066914.95878.6D
- Prati F, Di Mario C, Moussa I, Reimers B, Mallus MT, Parma A, et al. In-stent neointimal proliferation correlates with the amount of residual plaque burden outside the stent: an intravascular ultrasound study. Circulation 1999;99:1011-1014 https://doi.org/10.1161/01.CIR.99.8.1011
- Gaillard E, Bergeron P, Deplano V. Influence of wall compliance on hemodynamics in models of abdominal aortic aneurysm. J Endovasc Ther 2007;14:593-599 https://doi.org/10.1583/1545-1550(2007)14[593:IOWCOH]2.0.CO;2
- Li Z, Kleinstreuer C. Computational analysis of type II endoleaks in a stented abdominal aortic aneurysm model. J Biomech 2006;39:2573-2582 https://doi.org/10.1016/j.jbiomech.2005.09.002
- Lawrence-Brown MM, Sun Z, Semmens JB, Liffman K, Sutalo ID, Hartley DB. Type II endoleaks: when is intervention indicated and what is the index of suspicion for types I or III? J Endovasc Ther 2009;16:I106-I118
피인용 문헌
- Endovascular stent graft repair of abdominal aortic aneurysms: Current status and future directions vol.1, pp.1, 2010, https://doi.org/10.4329/wjr.v1.i1.63
- Computation of hemodynamics in the left coronary artery with variable angulations vol.44, pp.10, 2010, https://doi.org/10.1016/j.jbiomech.2011.04.033
- Computational Fluid Dynamics Analysis of the Effect of Plaques in the Left Coronary Artery vol.2012, pp.None, 2010, https://doi.org/10.1155/2012/504367
- A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus. vol.40, pp.6, 2013, https://doi.org/10.1118/1.4803497
- Free Tools and Strategies for the Generation of 3D Finite Element Meshes: Modeling of the Cardiac Structures vol.2013, pp.None, 2010, https://doi.org/10.1155/2013/540571
- Impact of plaques in the left coronary artery on wall shear stress and pressure gradient in coronary side branches vol.17, pp.2, 2014, https://doi.org/10.1080/10255842.2012.671308
- Delaunay Tetrahedralization of the Heart Based on Integration of Open Source Codes vol.490, pp.1, 2010, https://doi.org/10.1088/1742-6596/490/1/012131
- Commentary: Computational Modeling of Contemporary Stent-Grafts vol.22, pp.4, 2010, https://doi.org/10.1177/1526602815590370
- Does Lower Limb Exercise Worsen Renal Artery Hemodynamics in Patients with Abdominal Aortic Aneurysm? vol.10, pp.5, 2010, https://doi.org/10.1371/journal.pone.0125121
- Hemodynamic Functions of Fenestrated Stent Graft under Resting, Hypertension, and Exercise Conditions vol.3, pp.None, 2010, https://doi.org/10.3389/fsurg.2016.00035
- Effect of a Flared Renal Stent on the Performance of Fenestrated Stent-Grafts at Rest and Exercise Conditions vol.23, pp.5, 2010, https://doi.org/10.1177/1526602816651425
- Hemodynamic Performance of Multilayer Stents in the Treatment of Aneurysms with a Branch Attached vol.9, pp.None, 2010, https://doi.org/10.1038/s41598-019-46714-7
- The added value of CT virtual angioscopy to MDCT angiography in the evaluation of aortic diseases vol.45, pp.8, 2010, https://doi.org/10.1007/s00261-020-02607-2
- Review of the Development of Hemodynamic Modeling Techniques to Capture Flow Behavior in Arteries Affected by Aneurysm, Atherosclerosis, and Stenting vol.144, pp.4, 2022, https://doi.org/10.1115/1.4053082