DOI QR코드

DOI QR Code

Tibial intramedullary canal axis and its influence on the intramedullary alignment system entry point in Koreans

  • Kwak, Dai-Soon (Catholic Institute for Applied Anatomy.Department of Anatomy, School of Medicine, The Catholic University of Korea) ;
  • Han, Chang-Whan (Somang Orthopedic Clinic) ;
  • Han, Seung-Ho (Catholic Institute for Applied Anatomy.Department of Anatomy, School of Medicine, The Catholic University of Korea)
  • Received : 2010.06.14
  • Accepted : 2010.08.25
  • Published : 2010.09.30

Abstract

Using computerized tomographic data and three dimensional model, we studied the influence of tibial intramedullary canal axis and other morphologic factors of the tibia on the entry point for tibial intramedullary alignment guides. Various anatomical parameters including tibial anteroposterior dimensions (AP), mediolateral dimensions (ML), aspect ratio (ML/AP), bowing and the intramedullary canal axis were studied. In addition, the entry point for the intramedullary alignment guide for primary and revision total knee arthroplasty were studied. The averaged entry point at the level of the tibial plateau was $5.7{\pm}2.2$ mm anterior and $4.3{\pm}2.0$ mm lateral to the classical entry point (P<.001). Furthermore, this entry point was more anterolateral in females when compared to males (P<.001). At a depth 10 mm below the tibial plateau, the entry point was on average $8.8{\pm}1.9$ mm anterior and $2.9{\pm}1.9$ mm lateral to the center of the cut surface. With increasing tibial varus the entry point tended to shift laterally at both levels (r=0.49) (P<.001). In Korean, the entry point for tibial intramedullary alignment systems is anterolateral to the classically described entry point. Moreover, the increment of tibial varus necessitates more lateral placement of the entry point. Intraoperatively, the entry point can be localized during primary knee arthroplasty to a point $15.9{\pm}2.8$ mm anterior to and $1.2{\pm}2.8$ mm lateral to the lateral tibial spine. For revision knee arthroplasty the point is on average $8.8{\pm}1.9$ mm anterior and $2.9{\pm}1.9$ mm lateral to the center of the cut surface of the tibia at a depth of 10 mm from the articular surface.

Keywords

Acknowledgement

Supported by : National Research Foundation

References

  1. Benjamin J. (2006). Component alignment in total knee arthroplasty. Instr Course Lect 55: 405-412
  2. Bloebaum RD, Bachus KN, Mitchell W, Hoffman G, Hofmann AA. (1994). Analysis of the bone surface area in resected tibia. Implications in tibial component subsidence and fixation. Clin Orthop Relat Res 309: 2-10
  3. Hicks CA, Noble P, Tullos H. (1995). The anatomy of the tibial intramedullary canal. Clin Orthop Relat Res 321: 111-116
  4. Ishii Y, Ohmori G, Bechtold JE, Gustilo RB. (1995). Extramedullary versus intramedullary alignment guides in total knee arthroplasty. Clin Orthop Relat Res 318: 167-175
  5. Matsui Y, Kadoya Y, Uehara K, Kobayashi A, Takaoka K. (2005). Rotational deformity in varus osteoarthritis of the knee: analysis with computed tomography. Clin Orthop Relat Res 433: 147-151
  6. Moreland JR. (1988). Mechanisms of failure in total knee arthroplasty. Clin Orthop Relat Res 226: 49-64
  7. Scuderi GR, Insall JN. (1989). The posterior stabilized knee prosthesis. Orthop Clin North Am 20: 71-78
  8. Westrich GH, Haas SB, Insall JN, Frachie A. (1995). Resection specimen analysis of proximal tibial anatomy based on 100 total knee arthroplasty specimens. J Arthroplasty 10: 47-51 https://doi.org/10.1016/S0883-5403(06)80064-1
  9. Whiteside LA, Summers RG. (1983). Anatomic landmarks for an intramedullary alignment system for total knee replacement. Orthop Trans 7: 546-547

Cited by

  1. 한국인 척추 연구를 위한 형상 / 물성 정보 구축 vol.11, pp.10, 2011, https://doi.org/10.5392/jkca.2011.11.10.488
  2. Analysis on anatomical references to assess the coronal alignment of tibial and femoral cuts in mega prosthetic knee replacement vol.15, pp.2, 2010, https://doi.org/10.1007/s10195-013-0277-4
  3. During forearm rotation the three-dimensional ulnolunate distance is affected more by translation of the ulnar head than change in ulnar variance vol.44, pp.5, 2010, https://doi.org/10.1177/1753193418795638
  4. Finite Element Analysis of Human Tibia Modeled as a Functionally Graded Material vol.2, pp.3, 2010, https://doi.org/10.1115/1.4044054
  5. Variability of Sagittal Plane Proximal Tibial Morphology and Its Effect on Stem Placement in Total Knee Arthroplasty vol.13, pp.None, 2022, https://doi.org/10.1016/j.artd.2021.10.018