Experimental Evaluation of Seismic Performance Factors for Tall Diagrid Structure

초고층 다이아 그리드 구조의 실험적 내진성능계수 평가

  • 배재훈 (고려대학교 건축사회환경공학부) ;
  • 주영규 (고려대학교 건축사회환경공학부) ;
  • 김영주 (고려대학교 건축사회환경공학부) ;
  • 김상대 (고려대학교 건축사회환경공학부)
  • Received : 2009.11.15
  • Accepted : 2009.12.10
  • Published : 2010.02.27

Abstract

A new freeform structure representing "Diagrid, Cantilevered, Tilted." which has been considered not only its distinctive appearance but also the structural advantages becomes one of the trends in tall building design. Especially in the Diagrid system, loads can be distributed through bracing frame so that it can be save the materials since it has more effective in the structure behavior. But the seismic performance index such as response modification factor is not clearly defined yet. Even though the diagrid is supposed to show higher seismic performance, it is underestimated due to the lack of reliable data. In this paper the response modification factor for the diagrid system is experimentally explored.

최근 초고층 건물에 구조적인 측면을 고려한 Freeform Structure라는 개념이 등장하고 있다. 이 형태는 Diagrid, Cantilevered, Tilted로 대변될 수 있는데 특히 다이아 그리드 시스템은 횡저항에 하중의 흐름을 가새 프레임을 따라 분산시킴으로써 효율적인 거동을 보이기 때문에 그만큼 부재를 경량화시킬 수가 있다. 그러나 Diagrid 구조시스템의 내진성능 평가를 위한 반응수정계수에 대한 신뢰성 있는 자료가 없기 때문에 우수한 내진성능이 예상됨에도 불구하고 기타구조 등으로 설계되고 있다. 본 연구에서는 실대형 실험을 통해 Diagrid 구조의 반응수정계수를 실험적으로 규명하고자 한다.

Keywords

References

  1. 김영학, 정연백, 석원균, 박순전, 이주호(2007) 초대형 대각가새(Diagrid) 부재 제작 및 시공방법에 관한 사례 연구, 한국강구조학회 학술발표대회논문집, pp.728-733.
  2. 주영규, 엄태성, 김진호, 장인화, 한기명, 안선미(2007) Diagrid 접합부의 구조성능 평가, 한국강구조학회 학술발표대회논문집, pp.794-799.
  3. 변태우, 박순전, 주영규, 김상대(2008) 초대형 대각가새 시스템의 접합부 성능에 관한 연구, 한국강구조학회 학술대회발표집, pp.215-218.
  4. ATC (1995) Structural Response Modification Factors, Report No. ATC-19, Applied Technology Council, Redwood City, California.
  5. Charnish, B. and McDonnell, T. (2008) The Bow: Unique Diagrid Structural System for a Sutainable Tall Building, CTBUH 8th World Congress 2008.
  6. Kim, J.S., Kim, Y.S., and Lho, S.H. (2008) Structural Schematic Design of a Tall Building in Asia using the Diagrid System
  7. Ali, M.M. and Kyoung, S.M. (2007) Structural Developements in Tall Buildings: Current Trends and Future Prospects. Architectural Science Review Vol. 50, No. 3, pp.205-223. https://doi.org/10.3763/asre.2007.5027
  8. Moon, K.S., Jerome, J.C., and John, E.F. (2007) Diagrid structural system for tall buildings: Characteristic and methodology for preliminary. The structural design of tall and special buildings. Vol. 16, pp.205-230. https://doi.org/10.1002/tal.311
  9. SOM Reprot (2008) Proposed methodology to determine R-values for steel diagrid framed systems, SOM, New York.