References
- Jokstad A, Braegger U, Brunski JB et al : Quality of dental implants. Int Dent J 53 : 409, 2003.
- Huang HM, Chiu CL : Early detection of implant healing process using resonance frequency analysis. Clin Oral Implants Res 14 : 437, 2003, https://doi.org/10.1034/j.1600-0501.2003.00818.x
- Puleo DA, Thomas MV : Implant surfaces. Dent Clin N Am 50 : 323, 2006, https://doi.org/10.1016/j.cden.2006.03.001
- Wennerberg A, Albrektsson T : Suggested guidelines for the topographic evaluation of implant surface. Int J Oral Maxillofac Implants 15 : 331, 2000,
- Albreksson T, Dahl E, Enbom L et al : Osseointegraged oral implants, A swedish multicenter study of 8139 consecutively inserted Nobelpharma implants, J Periodontol 59 : 287, 1988, https://doi.org/10.1902/jop.1988.59.5.287
- Eckert SE, Parein A, Myshin HL et al : Validation of dental implant systems through a review of lliterature supplied by system manufactures. J Prosthet Dent 77 : 271, 1997, https://doi.org/10.1016/S0022-3913(97)70184-7
- Wennerberg A, Albrektsson T, Andersson B et al : A histomorphometric and removal torque study of screw-shaped titanium. Clin Oral Implants Res 6 : 24, 1995, https://doi.org/10.1034/j.1600-0501.1995.060103.x
- Hall J, Lausmaa J : Properties of a new porous oxide surface on titanium implants. Appl Osseointegration Res 1 : 5, 2000.
- Ivanoff CJ, Widmark G, Johansson C et al : Histologic evaluation of bone response to oxidized and turned titamium micro-implants in human jaw bone. Int J Oral Maxillofac Implants 18 : 341, 2003,
- Vanden Bogaerde L, Rangert B, Wendelhag I : Immediate/early function of Branemark System TiUnite implants in fresh extraction sockets in maxillae and posterior mandibles: an 18-month prospective clinical study. Clin Implant Dent Relat Res 7 : 121, 2005. https://doi.org/10.1111/j.1708-8208.2005.tb00055.x
- SuI YT : The significance of the surface properties of oxidized titanium to the bone response: Special emphasis on potential biochemical bonding of oxidized titanium implant. Biomaterials 24 : 3893, 2003. https://doi.org/10.1016/S0142-9612(03)00261-8
- Sui YT, Johansson P, Byon E et al : Bone response to Mgincoporated, oxidized implnats in rabbit femur: Mechanical interlocking vs Biochemical bonding. Journal of Applied Biomaterials and biomechanics 3 : 18, 2005.
- Sui YT, Johansson CB, Byon E et al : The bone response to oxidized bioactive and non-bioactive implants. Biomaterials 26 : 6720, 2005, https://doi.org/10.1016/j.biomaterials.2005.04.058
- SuI YT : On the Bone Response to Oxidized Titanium Implants: The Role of Microporous Structure and Chemical Composition of the Surface oxide in Enhanced osseointegration (thesis). Goteborg, Sweden : University of Ooteborg. 2002,
- SuI YT, Johansson CB, Petronis S et al : Characteristics of the surface oxides on turned and electrochemically oxidized pure titanium implants up to dielectric breakdown: The oxidized thickness, micro-pore configurations, surface roughness, crystal structure and chemical composition. Biomaterials 23 : 491, 2002. https://doi.org/10.1016/S0142-9612(01)00131-4
- Meredith N : Assessment of implant stability as a prognostic determinant. Int J Prosthodont 11 : 491, 1998.
- Barewall RM, Oates TW, Meredith N et al : Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface. Int J Oral Maxillofac implants 18 : 641, 2003.
- Zhou Y, Jiang T, Qian M et al : Roles of bone scintigraphy and resoonance frequency analysis in evaluating osseointegration of endosseous implant. Biomaterials 29 : 461, 2008. https://doi.org/10.1016/j.biomaterials.2007.10.021
- Huwiler MA, Pjetursson BE, Bosshardt DD et al : Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation. Clin oral Implants Res 18 : 275, 2007. https://doi.org/10.1111/j.1600-0501.2007.01336.x
- Abrahamsson I, Bergllundh T, Linder E et al : Early bone formation adjacent to rough and turned endosseous implant surface. An experimental study in the dog. Clin Oral implants Res 15 : 381, 2004, https://doi.org/10.1111/j.1600-0501.2004.01082.x