Abstract
The A106 Gr B low carbon steel, which was used in the electric power plants and heavy chemical plants, was welded by multi-pass arc welding. The heat affected zone (HAZ) formed by welding was corroded in acid chloride solution, or in saturated $H_2S$ containing acid chloride solution, or in saturated $H_2S$ containing acid chloride solution under applied current. In this order of corrosion solution, the rate of corrosion increased, because $H_2S$ accelerated the iron dissolution, hydrogen evolution, and the formation of nonprotective FeS, whereas the applied current accelerated the electrochemical reaction. The scales formed in acid chloride solution consisted primarily of $Fe_3O_4$, while those formed in $H_2S$ containing acid chloride solution consisted primarily of $Fe_3O_4$ and FeS.