A Study on the Pretreatment Process for Sewage Reuse by Microfiltration Process

정밀여과에 의한 하수고도처리수의 재이용을 위한 전처리법에 관한 연구

  • 국영롱 (서울시립대학교 환경공학부) ;
  • 주재영 (서울시립대학교 환경공학부) ;
  • 배윤선 (서울시립대학교 환경공학부) ;
  • 이혜인 (서울시립대학교 환경공학부) ;
  • 정인호 (서울시립대학교 환경공학부) ;
  • 박철휘 (서울시립대학교 환경공학부)
  • Received : 2010.09.09
  • Accepted : 2010.10.12
  • Published : 2010.10.15

Abstract

It is evident that Korea will continue its battle with water shortage and alternative program are being taken into action. One of the main actions is reusing 1,800 tons of effluent of 357 sewage treatment plant located nationwide. Therefore this study supplemented ozone oxidation methods that would increase the efficiency of organic oxidation and coagulation. Through this method, fouling will be controled sufficiently by preventing membrane process in the system for advanced sewage treatment. In this study, ozone-coagulation-microfiltration membrane were used. The final removal efficiency of the pretreated water from the result of the ozone-coagulation were 50% of CODcr, 38% of TP and 11% of TOC respectively. Water quality treatment has decreased about 80% for TP. Ozone-coagulation-microfiltration membrane maintains the high flux while decreasing the number of organic matter and the membrane fouling, and reducing the TP. As a result, in order to reuse the water from the sewage, the ozone-coagulation-microfiltration membrane type must be considered in order to achieve the best efficiency.

Keywords

References

  1. 김영란, 진상엽, 이상희 (1999) 하수처리수 재이용의 타당성 연구, 서울시정개발연구원
  2. 박병규 (2006) 응집-막여과 공정에서 응집 플록의 침착에 의해 형성된 케이크층의 공극률 예측, 서울대학교 응용화학부 박사학위논문
  3. 환경부 (2008) 하수도 통계
  4. Amy G. L., Tan L., Davis M., K. (1991) The effects of ozonation and activated carbon adsorption on trihalomethane speciation, Wat. Res., 25, 191 https://doi.org/10.1016/0043-1354(91)90029-P
  5. Cho, J., G. Amy and J. Pellegrino. (2000) Membrane filtration of natural organic matter: Factors and mechanisms affecting rejection and flux decline with cgarge ultrafiltration(UF) membrane, J. Mem. Sci., 164. 89-110 https://doi.org/10.1016/S0376-7388(99)00176-3
  6. Lin, C., Lin, T., Hoa, O. J. (2000) Effect of substance characteristics on UF performance. Wat Res., 34(4). 1097-1106 https://doi.org/10.1016/S0043-1354(99)00273-0
  7. Mori, Y.,. Oota, T., Hashino, M., Takamura, M., Fujii. Y. (1998) "Ozone-micro filtration system". Desalination, 177, 211-218
  8. Singer P. C. (1990) Assessing ozonation research needs in water treatment. J. AWWA. 90, 78
  9. Schafer, A. I., U. Schwicker, M.M. Fischer, A, G. Fane. and. T.D waite. (2000) Microfiltration of colliod and natural organic matter, J. Mem. Sci., 171. 151-172 https://doi.org/10.1016/S0376-7388(99)00286-0
  10. Tomaszewska, M. and Mozia, S. (2002) Removal of organic matter from water by PAC/UF system, Wat. Res., 36(6). 4137-4143 https://doi.org/10.1016/S0043-1354(02)00122-7