Study of optimal reduction plan for wastewater sludge generated from oil refinery

정유 공장에서 발생된 폐수 슬러지의 최적 감량화 방안 연구

  • 최재우 (한국과학기술연구원 환경본부 물환경센터) ;
  • 정종민 (한국과학기술연구원 환경본부 물환경센터) ;
  • 심나탈리아 (한국과학기술연구원 환경본부 물환경센터) ;
  • 이상협 (한국과학기술연구원 환경본부 물환경센터) ;
  • 박철희 ((주)SK 기술원 Energy R&D Center)
  • Received : 2010.06.22
  • Accepted : 2010.08.06
  • Published : 2010.08.15

Abstract

In this study, anaerobic digestion, electro-oxidation and electro-fenton oxidation processes were investigated to reduce oily refinery sludge. Anaerobic digestion process was not suitable for oily activated sludge reduction because of characteristics itself and, as experimental results revealed, reduction efficiency was low for electro-oxidation process. However, 40% total suspended solid reduction of oily activated sludge was obtained by electro-fenton oxidation process, operating at pH=1, 0.5 A and $Fe^{2+}$:$H_2O_2$ ratio = 1:30. In addition, higher reduction efficiency was obtained as reaction time was increased (30, 60, 90, 120 min) despite of low $H_2O_2$ concentration. From the results, it has been investigated that electro-fenton oxidation is efficient process for oily activated sludge reduction.

Keywords

References

  1. Clescerl L.S., Greenberg A.E., Eaton A.D. (1992) Standard Methods for the Examination of water and wastewater. 18th Ed. Washington, D.C.
  2. Abdelwahaba O., Aminb N.K., El-Ashtoukhyb E.S.Z. (2009) Electrochemical removal of phenol from oil refinery wastewater. J. Hazard. Mater., 163, pp.711-716 https://doi.org/10.1016/j.jhazmat.2008.07.016
  3. Buxton G.V., Greenstock C.L., Helman W.P., Ross A.B. (1988) Critical review of rate constants for reaction of hydrated electrons, hydrogen atoms and hydroxyl radicals ($\bullet$OH/$\bullet$O−) in aqueous solution, J. Phys. Chem. Ref. Data, 17, pp.513-886. https://doi.org/10.1063/1.555805
  4. Jou C.H.G and Huang G.C. (2003) A pilot study for oil refinery wastewater treatment using a fixe-dfilm bioreactor, Adv. Environ. Res., 7, pp.463-469. https://doi.org/10.1016/S1093-0191(02)00016-3
  5. Parsons S. (2004) Advanced Oxidation Process for Water and Wastewater Treatment. IWA publishing, IWA.
  6. Pozzo A.D., Ferrantelli P., Merli C., Petrucci E. (2005) Oxidation efficiency in the electro-Fenton process, J. Appl. Electrochem., 35(4), pp.391-398. https://doi.org/10.1007/s10800-005-0801-1
  7. Qiang Z.M., Chang J.H., Huang C.P. (2003) Electrochemical regeneration of $Fe^{2+}$ in Fenton oxidation processes, Water Res., 37, pp.1308-1319. https://doi.org/10.1016/S0043-1354(02)00461-X
  8. Rigg T., Taylor W., Weiss J. (1954) The rate constant of the reaction between hydrogen peroxide and ferrous ions, J. Chem. Phys., 22, pp.575-577. https://doi.org/10.1063/1.1740127
  9. Sun Y., Pignatello J.J. (1993) Photochemical reactions involved in the total mineralization of 2,4-D by $Fe^{3+}$/$H_{2}O_{2}$/UV, Environ. Sci. Technol., 27, pp.304-310. https://doi.org/10.1021/es00039a010
  10. Tang W.Z. and Huang C.P. (1996) 2,4-Dichlorophenol oxidation kinetics by Fenton's reagent, Environ. Technol., 17, pp.1371-1378. https://doi.org/10.1080/09593330.1996.9618465
  11. Toril I.R.U. (2001) Chemical characterization of produced water from four off-shore oil production platforms in the North Sea, Chemosphere, 39, pp.2593-2606.
  12. Vlyssides A.G., Israilides C.J., Loizidou M., Karvouni G., Mourafeti V. (1997) Electrochemical treatment of vinasse from beet molasses, Water Sci. Technol., 36, pp.271-278.
  13. Wang Q. and Lemley A.T. (2001) Kinetic model and optimization of 2,4-D degradation by anodic Fenton treatment, Environ. Sci. Technol., 35, pp.4509-4514. https://doi.org/10.1021/es0109693
  14. Walling C. and Goosen A. (1973) Mechanism of the ferric ion catalysed decomposition of hydrogen peroxide: effects of organic substrate, J. Am. Chem. Soc., 95, pp.2987-2991. https://doi.org/10.1021/ja00790a042
  15. Zhang H., Choi H.J., Huang C.P. (2005) Optimization of Fenton process for the treatment of landfill leachate, J. Hazard. Mater., 125, pp.166-174. https://doi.org/10.1016/j.jhazmat.2005.05.025
  16. Zhang H., Zhang D., Zhou J. (2006) Removal of COD from landfill leachate by electro-Fenton method, J. Hazard. Mater., 135, pp.106-111. https://doi.org/10.1016/j.jhazmat.2005.11.025
  17. Zhao R., Wang Y., Ye Z., Borthwick A.G.L., Ni J. (2006) Oil field wastewater treatment in biological aerated filter by immobilized microorganism, Process Biochem., 41, pp.1475-1483. https://doi.org/10.1016/j.procbio.2006.02.006