DOI QR코드

DOI QR Code

한국전력 노후 가공송전선의 동적송전용량에 대한 재평가

A Reassessment for Dynamic Line Rating of Aged Overhead Transmission Lines in Kepco's Network

  • 김성덕 (한밭대학교 전기전자제어공학부)
  • 투고 : 2010.08.02
  • 심사 : 2010.08.25
  • 발행 : 2010.10.31

초록

During the past 2 decades, many electric power companies have been searching various solutions in order to supply power with economical and more efficiency in the present transmission utilities. Most interesting method to increase the line capacity of overhead transmission lines without constructing any new line might be to adapt Dynamic Line Rating(DLR). Specified rating is normally determined by any current level, not by conductor temperature. Although specified rating is essential to design transmission line, dip may be the most important factor in limiting transmission capacity. Transmission lines built by the oldest dip criterion among the 3 different design criteria for conductor dip are nearly over one-half of all Kepco's transmission lines. This paper describes an up-rating method for those transmission lines in order to apply DLR technique. Based on limit dip conductor temperature and current of the transmission lines, limitation performance and effectiveness in applying DLR with weather model are analyzed. As a result of analysis, it can be shown that an improved method could be effectively used for increasing the line rating of old transmission line which was built by the design criterion with low dip margin.

키워드

참고문헌

  1. R.L. Jackson, R.R. Gibbon, J.M. Ferguson and K.G. Lewis, “The condition of the supergrid and a strategy for refurbishment”, International Conference on Revitalizing Transmission and Distribution Systems, pp. 44-48, 1987.
  2. Draft standard for calculating the current-temperature relationship for bare overhead conductors, IEEE Standard P738, 1999.
  3. IEEE Standard for Calculating the Current-Temperature of Bare Overhead Conductors, IEEE Std 738-2006.
  4. J.S. Engelhardt, and S.P. Basu, “Design, installation and field experience with an overhead transmission dynamic line rating system”, Proceedings of IEEE, Transmission and Distribution, pp. 366-370, 1996. https://doi.org/10.1109/TDC.1996.545961
  5. 가공송전선 이도 설계기준 - 1211, 한국전력공사, 2003.
  6. 가공송전선 이도 설계기준 - 1211, 해설서, 한국전력공사, 2003.
  7. L. Ren, J. Xiuchen and S. Gehao, “DLR Research for dynamic increasing transmission capacity”, 2008 International Conference on Condition Monitoring and Diagnosis, Beijing China, 2008.
  8. 송전선로 지상고 설계기준 - 1020, 한국전력공사, 2003.

피인용 문헌

  1. Dynamic Line Rating Prediction in Overhead Transmission Lines Using Artificial Neural Network vol.28, pp.1, 2014, https://doi.org/10.5207/JIEIE.2014.28.1.079