Abstract
Considering six screen matrix to select an optimum remediation method for the Kunsan military base contaminated with petroleum oil, the following order was obtained: landfarming > biopile > soil washing > thermal desorption = incineration. When the landfarming method was applied for the remediation of 2,250 $m^3$ soil contaminated with petroleum oil ranging from 500 to 2,404 mg/kg as TPH, contamination level decreased below target concentration 450 mg/kg after 20~42 days depending on the initial contamination. From the evaluation of case studies of landfarming, it is suggested that ratty-truss or single-arch structure is suitable in the landfarming plant for the treatment of large-scale contaminated soil requiring long period of remediation. But, vinyl-house structure is suitable in the landfarming plant for the treatment of small-scale contaminated soil requiring short period of remediation. Therefore vinyl-house structure is recommended in the remediation of contaminated soil less than 5,000 $m^3$ requiring within 1 year of remediation period but ratty-truss or single-arch structure is recommended for the remediation of contaminated soil more than 5,000 $m^3$.