DOI QR코드

DOI QR Code

Collection Efficiency Enhancement of Spray Tower Scrubber by Introducing Electrospray with Two-flow Nozzle

분무탑식 스크러버에서 이류체 정전분무에 의한 집진효율의 향상

  • Hwang, You-Seong (Department of Environmental Engineering, Hanseo University) ;
  • Kim, Jong-Ho (Department of Environmental Engineering, Hanseo University) ;
  • Kim, Jong-Hyeon (Department of Environmental Engineering, Hanseo University)
  • Received : 2010.03.31
  • Accepted : 2010.06.04
  • Published : 2010.06.30

Abstract

There have been a number of efforts to satisfy national emission regulations and reduce the amount of emitted air pollutants. There are several air pollution control devices, however, only wet scrubber is efficiently used to remove particulate matters and gaseous pollutants, even if it has minimum collection efficiency in the particle size range of $0.1{\sim}1{\mu}m$. This study aimed to improve the collection efficiency of a spray tower type scrubber by introducing an electrospray system with two-flow nozzle. We found that the collection efficiency of a spray tower type scrubber was similar to that of a conventional wet scrubber. However, installation of an electrospray system in the scrubber resulted in drastic further improvement of collection efficiency comparing to that of a conventional scrubber, which is 26%, 35.2%, and 45.1% at the liquid to gas ratio of 0.26 $L/m^3$ and 19.9%, 35.1%, and 42.5% at 0.34 $L/m^3$ for the applied voltage of -30 kV, -35 kV, and -40 kV, respectively. Therefore, we found that the introduction of an electrospray system is very effective to improve the collection efficiency of a spray tower type scrubber.

Keywords

References

  1. Bailey, A.G. (1998) Electrostatic Spraying of Liquids, John Wiley & Sons Inc., 107-115.
  2. Cooper, C.D. and F.C. Alley (2002) Air Pollution Control; A Design Approach, Waveland Press, Inc.
  3. Englert, N. (2004) Fine particles and human health-a review of epidemiological studies, Toxicology Letters, 149, 235-242. https://doi.org/10.1016/j.toxlet.2003.12.035
  4. Ganan-Calvo, A.M., J. Davila, and A. Barrero (1997) Current and droplet size in the electrospraying of liquids. scaling laws, J. Aerosol. Sci., 28(2), 249-275. https://doi.org/10.1016/S0021-8502(96)00433-8
  5. Hinds, W.C. (1982) Aerosol Technology, John Willey & Sons Inc., 428-430, 191-196.
  6. Hobbs, P.V. (1993), Aerosol-Cloud-Climate interaction, Academic Press, Inc., 75-84.
  7. Hwang, Y.S. (2010) Removal of Fine Particles using Charged-droplet Scrubber, Master Thesis, Hanseo University. (in Korean with English abstract)
  8. Jaworek, A., W. balachandran, M. Lackowki, J. Kulon, and A. Krupa (2006) Multi-nozzle elecrtospray system for gas cleaning processes, Journal of Electrostatics, 64, 194-202. https://doi.org/10.1016/j.elstat.2005.05.006
  9. Jung, C.H. and K.W. Lee (1998) Filtration of fine particles by multiple liquid droplet and gas bubble system, Aerosol Sci. & Tech. 29(5), 389-401. https://doi.org/10.1080/02786829808965578
  10. Kim, J.H. (1999) The basic study on development of electrocharged scrubber, Korean J. of Atmos. Environ., 15(1), 33-39. (in Korean with English abstract)
  11. Kim, J.H. and C.S. Bae (2001) Liquid atomization and spray characteristics in electrostatic spray of twin fluids, Korean J. of Mechanical Science and Technology B, 25(11), 1552-1560. (in Korean with English abstract)
  12. Kim, J.H., U.H. Hwang, and S.D. Kim (1999) Effects of corona wind on the collection efficiency of electrostatic precipitator, Korean J. of KSEE, 21(7), 1323-1330. (in Korean with English abstract)
  13. Kim, K.T. (2003) Effects of the external electric field on electrospray characteristics, Master Thesis, Korea advanced Institute of Science and Technology. (in Korean with English abstract)
  14. Kim, S.D., J.H. Kim, and C.K. Bong (1995) A study on the characteristics of dust emission and electrostatic precipitation at the B-C oil combustion, Korean J. of KSEE, 17(12), 1271-1277. (in Korean with English abstract)
  15. Lee, H.S. (2009) Development of collection efficiency in electrostatic precipitator using electrospray, Master Thesis, Hanseo University. (in Korean with English abstract)
  16. Lee, M.H., K. Cho, A.P. Shah, and P. Biswas (2005) Nanostructured sorbents for capture of cadmium species in combustion environments, Environ. Sci. & Technol., 39(21), 8481-8489. https://doi.org/10.1021/es0506713
  17. Lee, M.H., S.B. Kim, Y.S. Hwang, J.H. Kim, and G.S. Kim (2006) Effective control of fine particles using an electrostatic coagulation between particle and water droplet, J. of ILASS-KOREA, 11(2), 98-104. (in Korean with English abstract)
  18. Lim, K.S., S.H. Lee, and H.S. Park (2006), Prediction for particle removal efficiency of a reverse jet scrubber, Journal of Aerosol Science, 37, 1826-1839. https://doi.org/10.1016/j.jaerosci.2006.06.010
  19. Michelson, D. (1990) Electrostatic Atomization, IOP Publishing Ltd., 43-49.
  20. Oliver, W. (2004) Electrohydrodynamic spraying-transport, mass and heat transfer of charged droplets and their application to the deposition of thin functional films, PhD thesis, University of Tubingen, The Swiss.
  21. Park, M.G., Y.G. Choi, and S.S. Kim (2006) Spray characteristics of charged injected 2-fluid nozzle for nonconducting liquid, J. of ILASS-KOREA, 11(3), 155-160. (in Korean with English abstract)
  22. Pilat, M.J., S.A. Jaasund, and L.E. Sparks (1974) Collection of aerosol particles by electrostatic droplet spray scrubbers. Environ. Sci. Technol., 6, 360-362.
  23. Sachchida, N.T. and R.G. Harrison (2002) Enhancement of contact nucleation by scavenging of charged aerosol particles, Atmospheric Research, 62, 57-70. https://doi.org/10.1016/S0169-8095(02)00020-0
  24. Samanta, A.M., K.A. Berube, F.D. Pooley, and R.J. Richards (1998) The response of lung epithelium to well characterised fine particles, Life Sciences, 62(19), 1789-1799. https://doi.org/10.1016/S0024-3205(98)00141-6
  25. Taylor, G.L. (1964) Disintegration of water drop in an electric field, Proc. R. SOC., A280, 383-397.