Abstract

This paper proposes a harmonics reduction technique for the input currents of three phase PWM converters. The quality of the phase angle information on the utility voltage connected to the PWM converters affects their control performance. Under a distorted utility voltage, the extracted phase angle based on the synchronous reference frame PLL method is distorted. This causes large harmonics in the input currents of a PWM converter. In this paper, a harmonics reduction method that makes the input currents in the PWM converter sinusoidal even under distorted utility conditions is proposed. By the proposed method, without additional hardware, the THD (Total Harmonic Distortion) of the input currents can be readily limited to below 5% which is the harmonic current requirements of IEEE std. 519. Its validity is verified by simulations and experimental results.

Keywords

References

  1. Vikaram Kaura and Vladimir Blasko, "Operation of a phase locked loop system under distorted utility conditions," IEEE Trans. on Ind. App., Vol. 33, No.1 pp. 58-63, 1997. https://doi.org/10.1109/28.567077
  2. Sang-Joon Lee, Jun-Koo Kang, and Seung-Ki Sul, "A new phase detecting method for power conversion systems considering distorted conditions in power system," in Conf. Rec. IEEE- IAS Annu. Meeting, Vol. 4, pp. 2167-2171, 1999.
  3. H. S. Song and K. Nam, "Dual current controller PWM converter under unbalanced input voltage conditions," IEEE Trans. on Ind. Elec., Vol. 46, No.5, pp. 953-959, 1999. https://doi.org/10.1109/41.793344
  4. Takaharu Takeshita and Nobuyuki Mastsui, "Current waveform control of PWM converter system for harmonic suppression on distribution system," Vol. 50, No. 6, pp. 1134-1139, Dec. 2003. https://doi.org/10.1109/TIE.2003.819667
  5. H.S. Mok, S.H. Kim, and Y.H. Cho, "Reduction of PMSM torque ripple caused by resolver position error," IEE Electron Letters, Vol. 43, No. 11, pp. 646-647, May 2007. https://doi.org/10.1049/el:20070296
  6. J. W. Dixon and B. T. Ooi, "Indirect current control of a unity power factor sinusoidal boost type 3-phase rectifier," IEEE Trans. on Ind. Elec., Vol. 35, pp. 508-515, Nov. 1988. https://doi.org/10.1109/41.9172
  7. Neam, Mahmoud M., El-Sousy, Fayez F. M., Ghazy, Moharned A., Abo-Adma, and Maqed A., "Intelligent control for DC-bus voltage of three-phase AC/DC PWM converters," Power Engineering, Energy and Electrical Drives, Powereng 2007 International Conference, pp.444-449, 2007.

Cited by

  1. Current Control of a Single-phase PWM Converter under the Distorted Source Voltage and Frequency Condition vol.20, pp.4, 2015, https://doi.org/10.6113/TKPE.2015.20.4.356
  2. Multiple-Period Repetitive Controller for Selective Harmonic Compensation with Three-Phase Shunt Active Power Filter vol.15, pp.3, 2015, https://doi.org/10.6113/JPE.2015.15.3.819
  3. Single-Stage Double-Buck Topologies with High Power Factor vol.11, pp.5, 2011, https://doi.org/10.6113/JPE.2011.11.5.655
  4. A Current Controller with the Compensation of the Input Voltage Unbalance and Distortion for Three Phase PWM Rectifier vol.16, pp.6, 2011, https://doi.org/10.6113/TKPE.2011.16.6.594