DOI QR코드

DOI QR Code

Microvascular Contrast Image in Portal Veins of Rat using Micro-CT

마이크로 CT를 이용한 BALB/C(흰쥐) 간문맥의 미세혈관 조영 영상

  • 이상호 (익산병원 영상의학과) ;
  • 임청환 (한서대학교 방사선학과) ;
  • 정홍량 (한서대학교 방사선학과) ;
  • 한범희 (서남대학교 방사선학과) ;
  • 모은희 (원광대학교병원 영상의학과) ;
  • 채규윤 (원광대학교 생명나노학부)
  • Received : 2010.05.17
  • Accepted : 2010.08.11
  • Published : 2010.09.28

Abstract

The study focuses on the value of Micro CT, a high resolution X-ray imaging device, by using it on rats to observe the overall portal vein image of the liver and the microvasculature of each lobes, visualize the 4 segmental lobes and acquire 3D image of the microvasculature through the reconstruction of sectional image data. Less of the damage to liver of the 5 mice, the device was able to separate the liver into 4 segmental lobes and displayed the 4 portal vein microvasculature in 2D. By using the 3D MIP technique, observation of the whole portal vein system microvasculature in 3D image was made possible along with each of the portal vein segment's branches until the 6th branch. Measured the size of 6branch, the average was measured at 1branch : $0.51mm{\pm}0.08$, 2 branch : $0.32mm{\pm}0.12$, 3 branch : $0.23mm{\pm}0.11$, 4 branch : $0.19mm{\pm}0.08$, 5 branch : $0.13mm{\pm}0.06$, 6 branch : $70.5{\mu}m{\pm}14.1$. The 3D image and the images of the microvasculatures in the result of study proved that the Micro-CT can be considered many useful device in obtaining high resolution images.

고해상도 엑스선 영상장치인 마이크로 CT를 이용, 흰쥐 간의 전체적인 문맥상과 각 간엽(lobe)의 미세혈관구조를 관찰하여 4개 분절 간엽의 구조를 영상화 하였고, 단축면상의 데이터를 3D영상으로 재구성한 미세혈관 구조의 입체적인 영상을 획득할 수 있는 마이크로 CT에 대한 유용성을 알아보고자 하였다. 5마리의 간 중에서 손상이 가장 적은 1개의 간을 4 개의 분절 간엽으로 각각 절단하여 문맥의 미세구조를 이차원으로 구성하였으며, MIP기법을 이용하여 간 문맥 전체 미세혈관의 3D영상을 얻었으며, 각 간엽의 미세혈관은 6분지까지 관찰할 수 있었다. 6 분지까지의 크기를 측정한 결과 평균치는 1 branch : $0.51mm{\pm}0.08$, 2 branch : $0.32mm{\pm}0.12$, 3 branch : $0.23mm{\pm}0.11$, 4 branch : $0.19 mm{\pm}0.08$, 5 branch : $0.13mm{\pm}0.06$, 6 branch : $70.5{\mu}m{\pm}14.1$ 로 측정되었다. 본 연구의 실험 결과에서 획득한 3차원의 입체 영상과 미세혈관 구조의 발견은 향후 고해상력의 영상을 얻을 수 있는 마이크로 CT가 많이 이용될 수 있을 것으로 기대된다.

Keywords

References

  1. S. Bourquin, Opt.Express, 3290, 2003.
  2. J. F. Hainfeld, D. N. Slatkin, and H. M. Smilowitz, “The use of gold nanoparticles to enhance radiotherapy in mice,” Phys Med Biol, 49:N309- N315, 2004. https://doi.org/10.1088/0031-9155/49/18/N03
  3. G. F. Paciotti, L. Myer, and D. Weinreich, “Colloidal gold: a novel nanoparticle vector for tumor directed drug delivery,” Drug Deliv, Vol,11, pp.169-183, 2004. https://doi.org/10.1080/10717540490433895
  4. J. Chen, F. Saeki, and B. J. Wiley, “Gold nanocages bioconjugation and their potential use as optical imaging contrast agents,” Nano Lett, Vol.5, pp.473-477, 2005. https://doi.org/10.1021/nl047950t
  5. M. C. Daniel and D. Astruc, “Goldnanoparticles assembly, supramolecular chemistry, quantum-size-related properties, and applications toward biology, catalysis, and nanotechnology,” Chem Rev, Vol.104, pp.293-346, 2004. https://doi.org/10.1021/cr030698+
  6. R. L. sandberg, C. Song. P and W. Waehulak O, "A Raymondsono High numerical aperture tabletop soft x-ray diffratio microscopy with 10-nm redution," proc. Natl. Acad. Sci. U.S.A, 105-24, 2008.
  7. C. T. Badea, B. Fubara, L. W. Hedlund, and G. A. Johnson, "4-D micro-CT of the mouse heart. Mol Imaging," Vol.4, pp.110-116, 2005.
  8. M. J. Paulus, S. S. Gleason, S. J. Kennel, P. R. Hunsicker, and D. K. Johnson, "High resolution X-ray computed tomography: an emerging tool for small animal cancer research," Neoplasia, Vol.2, pp.62-70, 2000. https://doi.org/10.1038/sj.neo.7900069
  9. E. L. Ritman, "Micro-computed tomography-current statusand developments," Annu Rev Biomed Eng, Vol.6, pp.185-208, 2004. https://doi.org/10.1146/annurev.bioeng.6.040803.140130
  10. Winter TCIII, Freeny PC and Nghiem HV, et al "Hepatic arterial anatomy in transplantation candidates: evaluation with three-dimensional CT arteriography," Radiology, 195:363-370, 1995. https://doi.org/10.1148/radiology.195.2.7724754
  11. S. Takahashi, T. Murakami, and M. Takamura, "Multi-detector row helical CT angiography of hepatic vessels : depiction with dual-arterial phase acquisition during single breath hold," Radiology, 222:81-88, 2002. https://doi.org/10.1148/radiol.2221010326
  12. J. W. Ludders, J. W. Wilson, and G. A. Ribble, "Microangiography and correlated histology: research technique for examining renal microcirculation," Am JVet Res,46:2536-8, 1985.
  13. T. F. Massoud, "Gambhir imaging in living subjects; seeing fundamental processes in a new light," Genes Dev, 7:545-80, 2003.
  14. M. D. Bentley, M. C. Ortiz, E. L. Ritman, and J. C. Romero, "The use of microcomputed tomography to study microvasculature in small rodents," Am J Physiol Regul Integr Comp Physiol, 282:F1267-79, 2002. https://doi.org/10.1152/ajpregu.00560.2001
  15. P. Soyer, "Segmental anatomy of liver, Utility of a nomenclature accepted worldwide," AJR, 161:572-573, 1993. https://doi.org/10.2214/ajr.161.3.8352107
  16. H. Bismuth, "Surgical anatomyh and anatomical surgery of the liver," World J Surg, 6:3-9, 1982 https://doi.org/10.1007/BF01656368
  17. "Gray’s Anatomy," via Wikipedia, 1918.
  18. T. Harada, "Liver and Gallbladder," Chapter 7 in Pathology of the Mouse.
  19. E. L. Ritman, S. M. Jorgensen, P. E. Lund, P. J. Thomas, J. H. Dunsmuir, and J. C. Romero, "Synchrotron -based micro-CT of in-situ biological basic functional units and their integration," Proc Soc Photo Opt Instrum Eng : 3149:13-24, 1997.
  20. C. A. Zarse, J. A. McAteer, A. J. Sommer, S. C. Kim, E. K. Hatt, and J. E. Lingeman, "Nondestructive analysis of urinary calculi using micro computed tomography," BMC Urol, 13:4-15, 2004.
  21. A. C. Langheinrich, R. M. Bohle, S. Greschus, N. Hackstein, G. Walker, and von Gerlach S, "Atherosclerotic l esions at micro CT: feasibility for analysis of coronary artery wall in autopsy specimens," Radiology, 231:675-681, 2004. https://doi.org/10.1148/radiol.2313021718
  22. Winter T III, Freeny P and H. Nghiem, "Hepatic arterial anatomy in transplantation candidates ; evaluation with three-dimensional CT arteriography," Radiology, 195:363-370, 1995. https://doi.org/10.1148/radiology.195.2.7724754
  23. E. Toyota, Y. Ogasawara, K. Fujimoto, T. Kajita, F. Higeto, and T. Asano, "Global heterogeneity of glomerular volume distribution in early diabetic nephropathy," Kidney Int, 66:855-61, 2004. https://doi.org/10.1111/j.1523-1755.2004.00816.x
  24. 엄태중, 강철, "바이오 포토닉스 영상기술," 물리학과첨단기술, pp.65-69, 2007(6).

Cited by

  1. CT Scan Findings of Rabbit Brain Infection Model and Changes in Hounsfield Unit of Arterial Blood after Injecting Contrast Medium vol.12, pp.9, 2012, https://doi.org/10.5392/JKCA.2012.12.09.270