References
- Norton MR. Multiple single-tooth implant restorations in the posterior jaws: maintenance of marginal bone levels with reference to the implant-abutment microgap. Int J Oral Maxillofac Implants 2006;21:777-84.
- Gotfredsen K. A 5-year prospective study of single-tooth replacements supported by the Astra Tech implant: a pilot study. Clin Implant Dent Relat Res 2004;6:1-8. https://doi.org/10.1111/j.1708-8208.2004.tb00021.x
- Norton MR. Biologic and mechanical stability of single-tooth implants: 4- to 7-year follow-up. Clin Implant Dent Relat Res 2001;3:214-20. https://doi.org/10.1111/j.1708-8208.2001.tb00143.x
- Wennstrom JL, Ekestubbe A, Grondahl K, Karlsson S, Lindhe J. Implant-supported single-tooth restorations: a 5-year prospective study. J Clin Periodontol 2005;32:567-74. https://doi.org/10.1111/j.1600-051X.2005.00715.x
- Solnit GS, Schneider RL. An alternative to splinting multiple implants: use of the ITI system. J Prosthodont 1998;7:114-9. https://doi.org/10.1111/j.1532-849X.1998.tb00190.x
- Guichet DL, Yoshinobu D, Caputo AA. Effect of splinting and interproximal contact tightness on load transfer by implant restorations. J Prosthet Dent 2002;87:528-35. https://doi.org/10.1067/mpr.2002.124589
- Wang TM, Leu LJ, Wang J, Lin LD. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis. Int J Oral Maxillofac Implants 2002;17:231-7.
- Hansson S. A conical implant-abutment interface at the level of the marginal bone improves the distribution of stresses in the supporting bone. An axisymmetric finite element analysis. Clin Oral Implants Res 2003;14:286-93. https://doi.org/10.1034/j.1600-0501.2003.140306.x
- Bozkaya D, Muftu S, Muftu A. Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis. J Prosthet Dent 2004;92:523-30. https://doi.org/10.1016/j.prosdent.2004.07.024
- Hansson S. Implant-abutment interface: biomechanical study of flat top versus conical. Clin Implant Dent Relat Res 2000;2:33- 41. https://doi.org/10.1111/j.1708-8208.2000.tb00104.x
- Hansson S, Norton M. The relation between surface roughness and interfacial shear strength for bone-anchored implants. A mathematical model. J Biomech 1999;32:829-36. https://doi.org/10.1016/S0021-9290(99)00058-5
- Palmer RM, Palmer PJ, Smith BJ. A 5-year prospective study of Astra single tooth implants. Clin Oral Implants Res 2000;11: 179-82. https://doi.org/10.1111/j.1600-0501.2000.tb00012.x
- Norton MR. The Astra Tech Single-Tooth Implant System: a report on 27 consecutively placed and restored implants. Int J Periodontics Restorative Dent 1997;17:574-83.
- Puchades-Roman L, Palmer RM, Palmer PJ, Howe LC, Ide M, Wilson RF. A clinical, radiographic, and microbiologic comparison of Astra Tech and Branemark single tooth implants. Clin Implant Dent Relat Res 2000;2:78-84. https://doi.org/10.1111/j.1708-8208.2000.tb00109.x
- Norton MR. Marginal bone levels at single tooth implants with a conical fixture design. The influence of surface macroand microstructure. Clin Oral Implants Res 1998;9:91-9. https://doi.org/10.1034/j.1600-0501.1998.090204.x
- Palmer RM, Smith BJ, Palmer PJ, Floyd PD. A prospective study of Astra single tooth implants. Clin Oral Implants Res 1997;8: 173-9. https://doi.org/10.1034/j.1600-0501.1997.080303.x
- Henry PJ, Laney WR, Jemt T, Harris D, Krogh PH, Polizzi G, Zarb GA, Herrmann I. Osseointegrated implants for single-tooth replacement: a prospective 5-year multicenter study. Int J Oral Maxillofac Implants 1996;11:450-5.
- Hwang D, Wang HL. Medical contraindications to implant therapy: part I: absolute contraindications. Implant Dent 2006;15:353-60. https://doi.org/10.1097/01.id.0000247855.75691.03
- Bragger U. Radiographic parameters for the evaluation of peri-implant tissues. Periodontol 2000 1994;4:87-97. https://doi.org/10.1111/j.1600-0757.1994.tb00009.x
- Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of currently used dental implants: a review and proposed criteria of success. Int J Oral Maxillofac Implants 1986;1:11-25.
- Markiewicz MR, Raina A, Chuang SK, Margarone JE 3rd, Dodson TB. Full-mouth rehabilitation with single-tooth implant restorations. Overview and report of case. NY State Dent J 2010; 76:36-42.
- Shin YK, Han CH, Heo SJ, Kim S, Chun HJ. Radiographic evaluation of marginal bone level around implants with different neck designs after 1 year. Int J Oral Maxillofac Implants 2006;21:789-94.
- Hansson S. The implant neck: smooth or provided with retention elements. A biomechanical approach. Clin Oral Implants Res 1999;10:394-405. https://doi.org/10.1034/j.1600-0501.1999.100506.x
- Scherrer SS, de Rijk WG. The effect of crown length on the fracture resistance of posterior porcelain and glass-ceramic crowns. Int J Prosthodont 1992;5:550-7.
Cited by
- Comparative Study of the Early Loading of Resorbable Blasting Media and Sandblasting with Large-grit and Acid-etching Surface Implants: A Retrospective Cohort Study vol.36, pp.6, 2014, https://doi.org/10.14402/jkamprs.2014.36.6.247
- Consecutive unsplinted implant-supported restorations to replace lost multiple adjacent posterior teeth: A 4-year prospective cohort study vol.73, pp.6, 2015, https://doi.org/10.3109/00016357.2014.983543
- Clinical Outcome of Hydroxyapatite Coated, Bioactive Glass Coated, and Machined Ti6Al4V Threaded Dental Implant in Human Jaws vol.25, pp.2, 2016, https://doi.org/10.1097/ID.0000000000000376