Consideration of Radioactive Contamination Materials Disposal

방사성오염물질 처분에 대한 고찰

  • Im, Hyun-Jin (Department of Nuclear Medicine, Seoul National University Hospital) ;
  • Kim, Tae-Yeob (Department of Nuclear Medicine, Seoul National University Hospital) ;
  • Lee, Hong-Jae (Department of Nuclear Medicine, Seoul National University Hospital) ;
  • Kim, Jin-Eui (Department of Nuclear Medicine, Seoul National University Hospital) ;
  • Kim, Hyun-Joo (Department of Nuclear Medicine, Seoul National University Hospital)
  • 임현진 (서울대학교병원 핵의학과) ;
  • 김태엽 (서울대학교병원 핵의학과) ;
  • 이홍재 (서울대학교병원 핵의학과) ;
  • 김진의 (서울대학교병원 핵의학과) ;
  • 김현주 (서울대학교병원 핵의학과)
  • Received : 2010.08.17
  • Accepted : 2010.08.31
  • Published : 2010.10.30

Abstract

Purpose: Nuclear medicine general operation room is radioactive control room which is used for the handling of radioisotope(R.I). Radioactive contamination materials must be under control and separated from general trash. With this experiments, we want to actively suggest the guideline of controling and operating radioactive contamination materials by measuring contamination degree and analyzing the causes which is not realized so far. Materials and Methods: Materials are selected from Oct. 2009 to March. 2010. salines which are used for labelling radiophamaceuticals and generator cap, saline needle cap, $^{99m}Tc$-needle cap saline vial which is generated from $^{99}Mo$/$^{99m}Tc$ generator. After measuring each surface contamination degree by survey meter, mean value and standard deviation one were solved out. Results: In result, After measuring surface contamination degree, radioactivity of saline for labelling radiophamaceuticals showed $14429{\pm}26378$ cpm (p<0.05) and in measured generators, foreign imported things showed that generator cap : $9{\pm}21$ cpm, saline vial : $17{\pm}28$ cpm. saline needle cap : $35{\pm}66$ cpm, $^{99m}Tc$-needle cap : $9{\pm}21$ cpm, saline vial $13{\pm}28$ cpm. domestic things showed that generator cap : $22852{\pm}52545$ cpm, saline needle cap : $87367{\pm}109711$ cpm, $^{99m}Tc$-needle cap : $9008{\pm}10459$ cpm, saline vial : $186416{\pm}158196$ cpm (p<0.05). Conclusion: The saline which is used for labelling, exceeded 1/10 of maximum permissible range. this is generated from radiophamaceuticals dilution procedure. and In generators, radioactive value of foreign import things showed closely background value. but which of domestic thing showed that exceeded more than 1000 values 1/10 of maximum permissible range. the causes of that is domestic generator is contaminated in manufacturing procedure. So, to dispose radioactive contamination materials which is could betaken out of, the control and operation must be radical under controlled by radioactive measuring, recording and equipping of its own. if this is kept well, we can prevent surely that radioactive waste could be disposed like as general trash.

핵의학과 종합조작실은 방사선 관리구역으로 이곳에서 발생된 방사성오염물질은 방사성폐기물로 간주하여 일반쓰레기와 별도로 관리를 해야 한다. 본 실험은 우리가 미처 인식하지 못해 일반쓰레기로 처분되었던 방사성오염물질의 오염도를 측정하고 원인을 분석하여 보다 적극적인 방사성폐기물 관리 운영의 필요성을 제시하고자 함이다. 측정대상은 방사성의약품을 표지하기 위해 사용된 생리식염수와 $^{99}Mo$/$^{99m}Tc$ generator(국산 및 외산)에서 발생한 generator cap, saline needle cap, $^{99m}Tc$-needle cap, saline vial로 하였고, gamma survey meter를 이용하여 평균값과 표준 편차(mean${\pm}$SD)로 나타냈다. 측정대상물질의 오염유무를 알기 위해 방사선 관리구역에서 반출될 수 있는 물질의 표면오염도인 최대허용표면오염도의 1/10(43.2 cpm)을 기준값으로 정하였다. 각각의 표면오염도를 측정한 결과 방사성의약품 표지를 위해 사용된 생리식염수에서는 $14,429{\pm}26,378$ cpm으로 최대 허용표면오염도의 1/10을 초과하였다. 그리고 측정된 generator중 외산에서는 generator cap: $17{\pm}28$ cpm, saline needle cap: $35{\pm}66$ cpm, $^{99m}Tc$-needle cap: $9{\pm}21$ cpm, saline vial: $13{\pm}28$ cpm으로 최대허용표면오염도의 1/10를 초과하지 않았지만 국산에서는 generator cap: $22,852{\pm}52,545$ cpm, saline needle cap: $87,367{\pm}109,711$ cpm, $^{99m}Tc$-needle cap: $9,008{\pm}10,459$ cpm, saline vial: $186,416{\pm}158,196$ cpm으로 최대 허용표면오염도의 1/10를 초과하였다. 외산 generator에서 발생한 측정대상물질은 일반폐기물로 처분하고 국산 generator와 방사성의약품을 표지하기 위해 사용된 생리식염수는 반드시 방사성폐기물로 간주하여 처분해야 한다. 따라서 일반쓰레기 뿐만 아니라 종합조작실에서 반출되는 모든 물질에 대한 자체적인 방사선측정, 기록 및 비치와 방사성폐기물에 대한 지속적인 교육을 통해 방사성 폐기물이 일반쓰레기로 처분되어 나가는 것을 예방 할 수 있을 것이다.

Keywords