The Korean Journal of Nuclear Medicine Technology (핵의학기술)
- Volume 14 Issue 2
- /
- Pages.45-49
- /
- 2010
- /
- 1229-9901(pISSN)
- /
- 2982-8406(eISSN)
Evaluation of Usefulness and Procedures for Safety of Radiopharmaceuticals in Cisternography
Cisternography 검사 시 사용되는 방사성의약품의 안정성 확보를 위한 검사도입 및 유용성 평가
- Kim, Da-Eun (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
- Yoo, Yeon-Wook (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
- Choi, Ho-Yong (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
- Kim, Yun-Cheol (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
- Kim, Yeong-Seok (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
- Won, Woo-Jae (Department of Nuclear Medicine and Research Institute, National Cancer Center) ;
- Kim, Seok-Ki (Department of Nuclear Medicine and Research Institute, National Cancer Center)
- 김다은 (국립암센터 핵의학과) ;
- 유연욱 (국립암센터 핵의학과) ;
- 최호용 (국립암센터 핵의학과) ;
- 김윤철 (국립암센터 핵의학과) ;
- 김영석 (국립암센터 핵의학과) ;
- 원우재 (국립암센터 핵의학과) ;
- 김석기 (국립암센터 핵의학과)
- Received : 2010.09.03
- Accepted : 2010.09.17
- Published : 2010.10.30
Abstract
Purpose: Several radiopharmaceuticals were used for cisternography. But recently, due to more short acquisition time, high resolution than other radiopharmaceuticals like In-111 DTPA, we were using Tc-99m DTPA in cisternography. Using of Tc-99m DTPA for intrathecal, was not officially recognised by the FDA. And there are matters of aseptic meningitis, muscular tetany, seizures by inappropriate radiopharmaceuticals handling. So, it is necessary to prevent adverse reactions while handling the radiopharmaceuticals using in cisternography. Therefore, this study aims to evaluation of usefulness and procedures for safety of radiopharmaceuticals in cisternography. Materials and Methods: Subjects were 12radioactive tracer vials using in cisternography in 2008 Dec. 16 - 2009 Dec. 30. (1) Radioactive tracer Vial test - We were measured NaPertechnetate radiation dose and volume, normal saline volume for dilution, source volume and dose activity for patient injection. And then, calculated mass of pure DTPA. (2) Bacterial endotoxin test - We performed pyrogen test using by negative/positive control vials which was added normal saline 0.2 mL and added normal saline 0.1 mL, Tc-99m DTPA 0.1 mL in test control vial. And then, reacted by digital hot plate in
뇌조 조영술에 이용되는 방사성의약품들 중 최근에는 Tc-99m DTPA를 이용한 뇌 척수액 영상이 대부분이다. 하지만 Tc-99m DTPA는 사용 시 무균수막염, 근육강직, 경련 등 여러 부작용이 발생할 우려가 있다. 따라서 Tc-99m DTPA의 이러한 부작용의 발생을 사전에 예방하기 위하여 안정성검사를 시행하였으며 그 유용성을 알아보고자 한다. 방사성의약품 Vial검사는 2008년 12월 16일 - 2009년 12월 30일에 뇌조조영술을 시행한 환자(n=12)를 대상으로 시행하였으며, 시술시 사용한 vial내의 DTPA 성분 (Mallinckrodt사의 Techscan-DTPA사용), NaPertechnate radiation dose 및 volume, 생리 식염수량, 환자주사용 용량 및 activity 등을 측정하여 순수 DTPA의 양을 계산하였다. 방사성의약품의 내독소평가(Bacterial endotoxin)는 2008년 12월 16일-2009년 12월 30일에 뇌조 조영술을 시행한 환자(n=12)를 대상으로 하였고, 이 때 사용한 DTPA vial의 Pyrogen test (LAL test)를 시행하였다. 시약이 함유된 Positive/Negative control vial(표준액)에 normal saline 0.2 mL을 주입하고, 동일한 Test control vial(실험액)에 normal saline 0.1mL 와 Tc-99m DTPA 0.1 mL로 주입하였으며 Digital hot plate에서