초록

In South Korea, as the living standard has been getting higher, meat consumption is steadily increasing. To meet the country's demand, livestock houses become larger and wider with increased raising density. In larger livestock houses, pollutants such as flake of pig skin, excrement, odor, various dusts and noxious gas like ammonia are excessively accumulated inside the facility. These will cause weak immunity for the pigs, diminution of productivity and degeneration of working condition. These problems can be solved through the ventilation performance of the facility. In the winter time, ventilation must be controlled to minimum to maintain a suitable thermal condition. However, this affects the other internal environmental condition because of the minimum ventilation. The installation of "wet air cleaner" especially in the winter time can be an alternative solution. For efficient application of this machine, there is a need to understand the existing ventilation condition and analyze the interaction of existing ventilation system with the wet air cleaner considering its appropriate location. In this study, the existing ventilation system as well as the internal environmental condition negatively inside the facility with the wet air cleaner has been studied using CFD technology. The CFD simulation model was validated from the study conducted by Seo et al. (2008). Results show that the elimination rate of ammonia was 39.4 % and stability could be improved to 35.1 % (Comparing case 5 to 1 where wet air cleaner machine was not used). It can therefore be concluded that case 5 shows the optimum location of a wet air cleaner in the livestock house.

키워드

참고문헌

  1. Bang, S. H., Jang, D. I., Jang, H. H., Lim, Y. I., 1998. Development of a measurement system for ammonia gas in swine housing. Journal of Korean Society for Agricultural Machinery 23(4): 359-364 (In Korean).
  2. Bjerg, B., K. Svidt., G. Zhang, 2002. Modeling of air inlets in CFD prediction of airflow in ventilated animal houses. Computers and Electronics in Agriculture 34:223-235 https://doi.org/10.1016/S0168-1699(01)00189-2
  3. Farbman, A. I., 1992. Cell Biology of Olfaction. Cambridge University. Press, Cambridge, UK.
  4. Harral, B. B., C. R. Boon., 1997. Comparison of predicted and measured air flow patterns in a mechanically ventilated livestock building without animals. Journal of Agricultural. Engineering Resarches. 66: 221-228. https://doi.org/10.1006/jaer.1996.0140
  5. Jones, J. B., Carmichael, N. L., Watches, C. M., White, R. P., Jones, R. B., 2000. The effects of acute simultaneous exposure to ammonia on the detection of buried odourized food by pigs. Applied Animal Behavior Science 65(4): 305-319. https://doi.org/10.1016/S0168-1591(99)00063-5
  6. KMTA, Korea Meat Trade Association, http://www.kmta.or.kr/
  7. Korea Institute of Planning and Evaluation for Technology of Food, Agriculture, Forestry and Fishenes, 2008. Ventilation study of pig house for effective application of a developed wet air cleaner (jn Korean)
  8. Lee, I. B., W. Park, B. Yu, 2002. Optimum design of forced ventilation system of piglet house using computer simulation. Presented at the 2002 ASAE annual international meeting. ASAE paper number: 024109. St, Joseph. Mich. :ASAE
  9. Lee, I. B., Lee, S., Kim, G., Sung, J., Sung, S., Yoon, Y., 2005. PIV verification of greenhouse ventilation air flows to evaluate CFD accuracy
  10. Lee, I. B., Sase, S., Han, H. T., Hong, H. K., Sung, S. H., Hwang, H. S., Hong, S. W., Seo, I. H., Kwon S. H., 2009, Ventilation design for a chick incubator using computational fluid dynamics. Japan Agricultural Research Quarterly 43(3): 227-237. https://doi.org/10.6090/jarq.43.227
  11. Lee, S. H., Cho, H. G., Choi, K. J., Oh, K. Y., Yu, B. K., Lee, I. B., Kim, K. W., 2005. Measurement of ammonia emission rate and environmental parameters from growing-finishing and farrowing house during hot season. Journal of Livestock House and Environment 11(1): 1-10 (In Korean).
  12. Seo, I. H., Lee, I. B., Hong, S. W., Hwang. H. S., Jessie P. B., Yoo. J. I., Kwon. K. S., Ha. T. H., Kim. H. T., 2008. Development of a cfd model to study ventilation efficiency of mechanically ventilated pig house. Journal of the Korean Society of Agricultural Engineers 50(1): 25-37 (in Korean). https://doi.org/10.5389/KSAE.2008.50.1.025
  13. Seo, I. H., Lee, I. B., Moon, O. K., Kim, H. T., Hwang, H. S., Hong, S. W., J. P. Bitog, Yoo, J. I., Kwon, K. S., Kim, Y. H., Han, J. W., 2009, Improvement of the ventilation system of a naturally ventilated broiler house in the cold season using computational simulations, Biosystems Engineering 104: 106-117. https://doi.org/10.1016/j.biosystemseng.2009.05.007
  14. Seo, I. H., Lee, I. B., Moon, O. K., Hwang, H. S., Hong, S. W., J. P. Bitog, Kwon, K. S., Z. Yec, 2010. CFD simulation model for analysis of ventilation system in a full-scale pig house including multiple animals. Biosystems Engineering. (In Review)
  15. Sun, H., R. Stowell, H. Keener, D. Elwell, F. Michel. 2002. Two-dimensional computational fluid dynamics modelling of air velocity and ammonia distribution in a high rise hog building. Transactions of the ASAE 45: 1559-1568.

피인용 문헌

  1. Analysis of Jet-drop Distance from the Multi Opening Slots of Forced-ventilation Broiler House vol.54, pp.2, 2012, https://doi.org/10.5389/KSAE.2012.54.2.055
  2. Analysis of Airflow Pattern in Plant Factory with Different Inlet and Outlet Locations using Computational Fluid Dynamics vol.39, pp.4, 2014, https://doi.org/10.5307/JBE.2014.39.4.310