DOI QR코드

DOI QR Code

Effects of Property Transformation and Marginal Gap Depending on Heat-Treatment of Metal-Porcelain by Gold Electro-Forming System

전기성형법을 이용한 치과용 금속-도재관의 소성에 따른 물성 변화가 변연 간격에 미치는 영향

  • 김치영 (부산가톨릭대학교 보건과학대학 치기공학과) ;
  • 정인성 (부산가톨릭대학교 보건과학대학 치기공학과) ;
  • 최성민 (부산가톨릭대학교 보건과학대학 치기공학과)
  • Received : 2010.04.01
  • Accepted : 2010.06.01
  • Published : 2010.06.28

Abstract

The objective of this paper is to study on the property transformation for materials and to evaluate the precision through marginal gap depending on heat-treatment of metal-porcelain by the gold electro-forming system. Specimens for evaluating property of hardness treat non-treat(HC), once(H1), twice(H2), and three times(H3) by heating, respectively. Specimens for marginal gap classified as each groups of special bonder(FS), special bonder, opaque(FO), special bonder, opaque, body(FB) and non-treatment(FC). As a result for micro-hardness test, the level of hardness on each groups of H1, H2, H3 decreased rather than HC group(p<0.05). In addition, marginal gap was not affected by the number of times being treated by heating. Therefore, the marginal fitness and the precision for mterials were not affected by the heat-treatment on the process to make GES metal-porcelain.

본 연구에서는 전기성형법을 이용한 금속-도재관의치의 도재소성에 따른 물성변화와 변연간격을 측정하여 변연 적합도에 미치는 영향을 고찰하여 정밀성을 평가하고자 한다. 물성변화와 변연간격을 관찰하기 위하여 물성 관찰시편은 소성 횟수를 고려하여 소성을 0회(HC), 1회(H1), 2회(H2), 3회(H3) 실시한 군으로 분류하였으며, 변연간격 관찰시편은 전용결합재 처리 군(FS), 전용결합재와 opaque 처리 군(FO), 전용 결합재와 opaque와 bady를 처리한 군(FB) 그리고 소성이 없는 군(FC)으로 분류하였다. 물성 관찰시편의 미소경도 관찰결과 대조군(HC)에 비하여 시험군(H1, H2, H3)의 경도가 감소하는 것을 관찰 할 수 있었다(p<0.05). 그리고 변연간격 관찰결과 GES 금속-도재관의 제작과정 중 발생하는 도재의 소성 횟수가 변연부에는 영향을 주지 않는 것을 관찰할 수 있었다(p>0.05).본 연구를 종합하여 분석한 결과 소성과정에서 열에 의한 연화열처리 효과로 경도감소가 발생하지만 변연간격에는 영향을 미치지 않은 결과를 얻어 GES 금속-도재관의 제작과정에서 도재소성으로 인한 변연 적합도 변화는 없으며 정밀도에도 영향을 미치지 않는 것으로 판단된다.

Keywords

References

  1. E. D. Rekow, "High-thechnology innovations and limitations for restorative dentistry," Dent Clin North Am, Vol.37 No.3, pp.513-24, 1993.
  2. H. S. Moon and J. J. Kim, "A Study on the physical Characteristics of the three commonly used die spacing materials," J Korean Acad of Prosthodont, Vol.37, No.3, pp.640-650, 1999.
  3. C. J. Wang, P. L. Millstein, and D. Nathanson, "Effect of cement, cement space, marginal design, seating aid materials," J Prosthet Dent, Vol.67 No.6, pp.786-790, 1992. https://doi.org/10.1016/0022-3913(92)90583-V
  4. C. Passon , R. H. Lambert, R. L. Lambert, and S. Newman, "The effect of multiple layers of die-spacer on crowns retention," Oper Dent, Vol.17, No.2, pp.42-49, 1992.
  5. R. Grajower, Y. Zuberi, and I. Lewinstein, "Improving the fit of crowns with die spacers," J Prosthet Dent, Vol.61, No.5, pp.555-563, 1989. https://doi.org/10.1016/0022-3913(89)90275-8
  6. S. H. Hung, K. S. Hung, J. D. Eick, and R. P. Chappell, "Marginal fit of porcelain-fused-to-metal and two type of ceramic crown," J Prosthet Dent, Vol.63, No.1 pp.26-31, 1990. https://doi.org/10.1016/0022-3913(90)90260-J
  7. S. N. White and V. Kipnis, "The Three-dimensional effects of adjustment and cementation on crown seating," Int J Prosthodont, Vol.6, No.3, pp.248-254, 1993.
  8. J. W. McLean and J. A. Von Fraunhofer, "The estimation of cement film thickness by an in vivo technique," Br Dent J, Vol.131, No.3, pp.107-111, 1971. https://doi.org/10.1038/sj.bdj.4802708
  9. A. Lomanto and S. Weiner, "A comparative study of ceramic crown margins constructed using different technique," J Prosthet Dent, Vol.67, No.6, pp.773-777, 1992. https://doi.org/10.1016/0022-3913(92)90580-4
  10. S. N. White, J. A. Sorensen, S. K. Kang, and A. A. Caputo, "Microleakage of new crown an fixed partial denture luting agents," J Prosthet Dent, Vol.67, No.2, pp.156-161, 1992. https://doi.org/10.1016/0022-3913(92)90447-I
  11. 정선희, 마장선, 정재헌, "정밀 연삭된 지대주와 합성수지 지대주를 이용한 보철물의 적합도에 대한 비교 연구“, 대한치과보철학회지, Vol.37, No.6, pp.825-834, 1999.
  12. D. B. Evan, "Correcting the fit of implant retained restorations by electric discharge machining," J Prosthet Dent, Vol.77, No.2, pp.212-215, 1997. https://doi.org/10.1016/S0022-3913(97)70238-5
  13. Y. Meada, M. Minoura, S. Tsutsumi, M. Okada, and T. Nokubi, "A CAD/CAM system for Removable denture. Part Ⅰ: Fabrication of complete Denture," Int J Prosthodont, Vol.7 No.1, pp.17-21 1994.
  14. S. Rinke, A. Huls, and L. Jahn, "Marginal accuracy and fracture strength of conventional and copy-milled all-ceramic crowns," Int J Prosthodont, Vol.8, No4, pp.303-310 1995.
  15. F. Behrend. “Gold electroforming system: GES restorations,” J Dent Technol, Vol.14, No.2, pp.31-37, 1997.
  16. 유병일, "표면처리 방법에 따른 electro forming gold와 레진과의 전단결합강도", 전북대학교 대학원, 석사학위논문, p.3, 2006.
  17. 신종우, "The art of electroforming Dentistry/고급 심미보철의 세계", 도서출판 참윤 publishing, pp.20-41, 2004.
  18. A. J. Raigrodski , C. Malcamp, and W. A. Rogers, "Electroforming technique," J Dent technol, Vol.15, No.6, pp.13-16, 1998.
  19. 박해광, “전기성형법 적용 도재관의 표면특성 및 결합력에 관한 연구”, 부산가톨릭대학교 보건과학대학원, 석사학위논문, p.33, 2008.
  20. 정명희 “치과주조용 제3형 금합금의 열처리에 따른 경도 및 미세조직”, 조선대학교 대학원, 석사학위논문, p.1, 2006.
  21. K. W. Boening, B. H. Wolf, A. E. Schmidt, K. Kastner, and M. H. Walter, "Clinical fit of Procera Allceram Crowns," J Prosthet Dent, Vol.84, No.4, pp.419-424, 2000. https://doi.org/10.1067/mpr.2000.109125
  22. M. K. Molin, S. L. Karlsson, and M. S. Kristiansen, "Influence of film thickness on joint bend strength of a ceramic/resin composite joint," Dent Mater, Vol.12, No.4, pp.245-249, 1996. https://doi.org/10.1016/S0109-5641(96)80030-3
  23. F. M. Gardener, "Marginal of complete crowns- Literature review," J Prosthet Dent, Vol.48, No.4, pp.396-400, 1982. https://doi.org/10.1016/0022-3913(82)90072-5
  24. D. K. Kim, I. H. Cho, J. H. Lim, and H. S Lim, "On The marginal fidelity of all-ceramic core using CAD/CAM system," J Korea Acad of Prosthodont, Vol.41, No.1, pp.20-34, 2003.
  25. S. Valderrama, N. Van Roekel, M. Andersson, C. J. Goodacre, and C. A. Munoz, "a comparison of the marginal and internal adaptation of titanium and gold-platinum-palladium metal ceramic crowns," Int J Prosthodont, Vol.8, No.1, pp.29-37, 1995.