References
- K. Miller, “Toxicological aspects of food”, Elsevier Applied Science, p. 139, 1987.
- B. A. Rotter, D. B. Prelusky, and J. J. Pestka, “Toxicology of deoxynivalenol”, J. Toxicol. Environ. Health, vol. 48. pp. 1-34, 1996.
- J. J. Pestka, “Enhanced surveillance of foodborne mycotoxins by immunochemical assay”, J. Assoc. Off. Anal. Chem., vol. 71, pp. 1075-1081, 1988.
- E. Tamiya and I. Karube, “Micro-biosensors for clinical Analysis”, Sensors and Actuators, vol. 15, pp. 199-207, 1988. https://doi.org/10.1016/0250-6874(88)87009-4
- Y. Hanazato, M. Nakako, and S. Shiono, “Multi- enzyme electrode using hydrogen ion-sensitive field effect transistor”, IEEE. Trans. Electron Devices, vol. ED-ee. pp. 47-51, 1986.
- S. Caras and J. Janata, “pH-based enzyme potentiometric sensors. part 1 - part 3”, Anal. Chem., vol. 57, pp. 1917-1925, 1985. https://doi.org/10.1021/ac00286a027
- H. Zhu, M. Bilgin, R. Bangham, D. Hall, A. Casamayor, P. Bertone, N. Lan, R. Jansen, S. Bidlingmaier, T. Houfek, T. Mitchell, P. Miller, R. A. Dean, M. Gerstein, and M. Snyder, “Global analysis of protein activities using proteome chip”, Science, vol. 293, pp. 2101-2105, 2001. https://doi.org/10.1126/science.1062191
- C. S. Effenhauser, G. J. M. Bruin, A. Paulus, and M. Ehrat, “Integrated capillary electrophoresis on flexible silicone microdevices: Analysis of DNA restriction fragments and detection of single DNA molecules on microchips”, Anal. Chem. vol. 72, pp. 5731-5735, 1997. https://doi.org/10.1021/ac000801k
- S. A. Zugel, B. J. Burke, F. E. Regnier, and F. E. Lytle, “Electrophoretically mediated microanalysis of leucine aminopeptidase using two-photon excited fluorescence detection on a microchip”, Anal. Chem.,vol. 72, pp. 5731-5735, 2000. https://doi.org/10.1021/ac000801k
- J. R. Webster, M. A. Burns, D. T. Burke, and C. H. Mastrangelo, “Monolithic capillary electrophoresis device with integrated fluorescence detector”, Anal. Chem. vol. 73, pp. 1622-1626, 2001. https://doi.org/10.1021/ac0004512
- D. Piscevic, W. Knoll, and M. J. Tarlov, “Surface plasmon microscopy of biotin-streptavidin binding reactions on UV-photopatterned alkanthiol self-assembled monolayers”, Supramolecular Science,vol. 2, pp. 99-106, 1995. https://doi.org/10.1016/0968-5677(96)89074-2
- J. Wang, M. P. Chatrathi, and B. Tian, “Microseparation chips for performing multienzymatic dehydrogenase / oxidase assays: Simultaneous electrochemicalmeasurement of ethanol and glucose”, Anal. Chem.,vol. 73, pp. 1296-1300, 2001. https://doi.org/10.1021/ac001205t
- M. A. Schwarz, B. Galliker, K. Fluri, T. Kappes, and P. C. Hauser, “A two-electrode configuration for simplified amperometric detection in a microfabricated electrophoretic separation device”, Analyst,vol. 126, pp. 147-151, 2001. https://doi.org/10.1039/b007383k
- C. Yuan, A. Chen, P. Kolb, and V. T. Moy, “Energy landscape of streptavidin-biotin complexes measured by atomic force microscopy”, Biochemistry,vol. 39, pp. 10219-10223, 2000. https://doi.org/10.1021/bi992715o
- J. Wen, Y. H. Lin, F. Xiang, D. W. Matson, H. R. Udseth, and R. D. Smith, “Microfabricated isoelectric focusing device for direct electrrospray ionization-mass spectrometry”, Electrophoresis, vol. 21, pp. 191-197, 2000. https://doi.org/10.1002/(SICI)1522-2683(20000101)21:1<191::AID-ELPS191>3.0.CO;2-M
- L. Licklider, X. Q. Wang, A. Desai, Y. C. Tai, and T. D. Lee, “A micromachined chip-based electrospray source for mass spectrometry”, Anal. Chem., vol. 72, pp. 367-375, 2000. https://doi.org/10.1021/ac990967p
- D.-S. Kim, Y.-T. Jeong, H.-J. Park, J.-K. Shin, P. Choi, J.-H. Lee, and G. Lim, “An FET-type charge sensor for highly sensitive detection of DNA sequence”, Biosens. Bioelectron., vol. 20, pp. 69-74, 2004. https://doi.org/10.1016/j.bios.2004.01.025
- D.-S. Kim, J.-E. Park, J.-K. Shin, P. K. Kim, G. Lim, and S. Shoji, “An extended gate FET-based biosensor integrated with a Si microfluidic channel for detection of protein complexes”, Sens. Actuators B, vol. 117, pp. 488-494, 2006. https://doi.org/10.1016/j.snb.2006.01.018
- B. Lim, B. Cho, J.-K. Shin, H.-J. Choi, S.-H. Seo, S.-W. Choi, and H. S. Chun, “Detection of zearalenone using a metal-oxide-semiconductor field-effect-transistor-based biosensor employing a Pt reference electrode”, Jpn. J. Appl. Phys., vol. 48, no. 6, pp. 06FJ06-1-06FJ06-4, 2009. https://doi.org/10.1143/JJAP.48.06FJ06
- J. Homola, S. S. Yee, and G. Gauglitz, “Surface plasmon resonance sensors: review”, Sens. Actuators B, vol. 54, pp. 3-15, 1999. https://doi.org/10.1016/S0925-4005(98)00321-9
- M. Mrksich and G. M. Whitesides, “Patterning self- assembled monolayers using microcontact printing: A new technology for biosensors?”, Trends Biotechnol., vol. 13, p. 228, 1995. https://doi.org/10.1016/S0167-7799(00)88950-7
- B. Razavi, Fundamentals of Microelectronics, John Wiley & Sons, New Jersey, pp. 298-303, 2008.
- P. Estrella, D. Paul, Q. Song, L. K. J. Stadler, L. Wang, E. Huq, J. J. Davis, P. K. Ferrigno and P, Migliorato, “Label-free sub-picomolar protein detection with field-effect transistors”, Analytical Chemistry, vol. 82, no. 9, pp. 3531-3536, 2010. https://doi.org/10.1021/ac902554v