참고문헌
- J. P. Rice and B. C. Johnson, “The NIST EOS thermalinfrared transfer radiometer,” Metrologia 35, 505-509 (1998). https://doi.org/10.1088/0026-1394/35/4/51
- F. Girard and T. Ricolfi, “Simple approach for temperature compensation in a transfer standard radiation thermometer,” in Proc. TEMPMEKO (Berlin, Germany, Jun. 2001), vol. 2, pp. 807-810.
-
O. Struband and C. Staniewicz, “Transfer radiation thermometer covering the temperature range of -50
$ to 1000${^{\circ}c}$ $$ ,” in Proc. TEMPMEKO (Berlin, Germany, Jun. 2001), vol. 2, pp. 811-816.${^{\circ}c}$ $ - H. W. Yoon, D. W. Allen, and R. D. Saunders, “Methods to reduce the size-of-source effect in radiometers,” Metrologia 42, 89-96 (2005). https://doi.org/10.1088/0026-1394/42/2/003
- B. Gutschwager, J. Hollandt, T Jankowski, and R. Gartner, “A vacuum infrared standard radiation thermometer at the PTB,” Int. J. Thermophys 29, 330-340 (2008). https://doi.org/10.1007/s10765-007-0349-x
- P. Blombergen, “On the uncertainty in the correction for the size-of-source effect,” Metrologia 46, 544-553 (2009). https://doi.org/10.1088/0026-1394/46/5/019
- P. Blombergen, “Analytical representations of the size-of-source effect,” Metrologia 46, 534-543 (2009). https://doi.org/10.1088/0026-1394/46/5/018
- P. Bloembergen, “On the correction for the size-of-source effect corrupted by background radiation,” in Proc. TEMPMEKO (Delft, Netherlands, Jun. 1999), vol. 2, pp. 607-612.
- G. Machin and M. Ibrahim, “A size of source effect and temperature uncertainty: II Low temperature systems,” in Proc. TEMPMEKO (Delft, Netherlands, Jun. 1999), vol. 2, pp. 687-692.
- I. Pusnik, G. Grgic, and J. Drnovsek, “System for the determination of the size-of-source effect of radiation thermometers with the direct reading of temperature,” Meas. Sci. Technol. 17, 1330-1336 (2006). https://doi.org/10.1088/0957-0233/17/6/007
- Y. S. Yoo, B.-H. Kim, C.-W. Park, D.-H. Lee, and S.-N. Park, “Size of source effect of a transfer reference thermometer suitable for the artefact of international comparisons near the room temperature,” in Proc. IMEKO (Lisbon, Portugal, 2009), pp. 1493-1496.
- P. Saunders and H. Edgar, “On the characterization and correction of the size-of-source effect in radiation thermometers,” Metrologia 46, 62-74 (2009). https://doi.org/10.1088/0026-1394/46/1/008
- J. B. Fowler, “A third generation water bath based blackbody source,” J. Res. Natl. Stand. Technol. 100, 591-599 (1995). https://doi.org/10.6028/jres.100.044
피인용 문헌
- Realization of a radiation temperature scale from 0 °C to 232 °C by a thermal infrared thermometer based on a multiple-fixed-point technique vol.50, pp.4, 2013, https://doi.org/10.1088/0026-1394/50/4/409
- Construction and Characterization of a Large Aperture Blackbody for Infrared Radiometer Calibration vol.32, pp.7-8, 2011, https://doi.org/10.1007/s10765-011-0962-6