초록
In the present study, computations for flow fields inside the CDI unit cells with electrodes and spacers have been made to evaluate their performance. Three types of unit cells that include a planar type, a serpentine channel type, and a spiral wound type were considered and their flow characteristics were compared. From the computational results, it is found that the serpentine channel type has a large flow resistance and can not guarantee the outflow flux for industrial applications. On the other hand, the planar type can sustain a large enough outflow flux but it's efficiency is low for the electrode-use because of the non-uniform velocity distribution inside the cell and dead zones in every corner. Finally, The spiral wound type has not only a large outflow flux as much as the planar type has, but also a high efficiency for the electrode-use because of uniform velocity distribution. From this comparison, we can expect that the spiral wound type of CDI unit cell would have a high performance deionization capability.