주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구

A study of Energy use Impacts by SHGCs of Windows in Detached House

  • 박률 (동의대학교 건축설비공학과) ;
  • 박종일 (동의대학교 건축설비공학과)
  • Park, Yool (Department of Building System, Dongeui University) ;
  • Park, Jong-Il (Department of Building System, Dongeui University)
  • 투고 : 2009.11.05
  • 발행 : 2010.04.10

초록

U-factor and solar heat gain coefficient(SHGC) usually can be used as the index to evaluate the thermal performance. U-factor is a concept for heat loss by the temperature difference between inside and outside, so it's useful to be applied in heating season. But SHGC that indicates the fraction of heat from incident solar radiation that flows through a window by means of optical transmission, as well as absorption, re-radiation and convection is for cooling season. In other words, U-factor and SHGC of windows by cities have to be reflected to select the window of the energy conservation. The purpose of this research is to analyze the energy use impacts by SHGCs of windows for detached house in Inchon and Ulsan through energy simulation by eQUEST.

키워드

참고문헌

  1. Korea Energy Economic Institute, 2007, 2006 yearbook of energy statistics.
  2. Cha J. H., 2003, General remarks of energy, Korea Energy Information Center.
  3. Kang Y. S., Jung M. H., Park H. J., Kim M. E. and Ilm P. C., 2008, A study of selecting proper glazing system for economize building energy, Journal of Korean Institute of Architectural Sustainable Environment and Building Systems Vol. 2 No. 1, pp. 15-21.
  4. Lee J. Y., 1998, Energy performance assessment technology development of advanced solar control window(ASCW), Korea Institute of Energy Research, pp. 15-39.
  5. Kim, H. J., Park, J. S., Shin, U. C. and Yoon, J. H., 2008, Heating and cooling energy performance analysis of an office building according to SHGC level of the double and triple glazing with low-e coating, The proceeding of the Korea Solar Energy Society 2008, pp. 90-95.
  6. Joshua A., Dariush. A. and Yu J. H., 2003, Future advanced windows for zero-energy homes. ASHRAE transactions, Vol. 109, No. 2, pp. 871-82.
  7. Dariush A., Howdy G., Joe H., Christian K. and Robin M., 2006, Performance criteria for residential zero-energy windows, ASHRAE transactions, Vol. 103, No. 1, pp. 176-85.
  8. Leigh S. B. and Won J. S., 2004, An analysis of demand for environmental controls on different residential building types, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 16 No. 10, pp. 960-968.
  9. Mun S. H., Kwon H. S. and Huh J. H., 2006, Methods to improved the cooling energy performance of low-e glazing, Proceedings of 2006 Architectural Institute of Korea, Vol. 26 No. 1, pp. 625-628.
  10. Yoo H. C., Oh Y. H. and Park S. K., 2005, The optimal window system of office buildings considering energy efficiency, Journal of the Korea Solar Energy Society, Vol. 25 No. 4, pp. 53-60.
  11. Kim B. S., Kim J. S., and Yim O. Y., 2004, Optimal windows transmittance by energy performance analysis and subjective evaluation in office building, Journal of the Korean Solar Energy Society, Vol. 24, No. 3, pp. 73-83.
  12. Seo D. H., Koh J. Y. and Park Y., 2009, Energy and economic analysis of heat recovery cogeneration loop with heat pump system by detailed building energy simula-tion, Korean Journal of Air-Conditioning and Refrigeration Engineering, Vol. 21 No. 2, pp. 71-78.
  13. Jang Y. S., Hong S. H., Park H. S., and Suh S. J., 2004, Energy efficiency rating and certification criteria of a detached house, Korea Journal of Architectural Institute, Vol. 20 No. 12, pp. 203-10.
  14. Kim B. S., Yoon J. H., Baek N. C., and Lee J. S., 2001, The estimate of simulation performance for a master plan of self-sufficient house, Journal of the Korean Solar Energy Society, Vol. 21 No. 4, pp. 13-20.
  15. http://apps1.eere.energy.gov/buildings/energyplus/ weather_data.cfm.