DOI QR코드

DOI QR Code

Analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in urine with certified reference material

인증표준물질(CRM)을 이용한 소변 중 대마 대사체 분석법 평가

  • Ko, Beom-Jun (Drug Aanlysis Laboratory, Supreme Prosecutors' Office) ;
  • Kim, Jin-Young (Drug Aanlysis Laboratory, Supreme Prosecutors' Office) ;
  • Kim, Jong-Sang (Department of Quality Management, Korea Institute of Construction Materials) ;
  • Lee, Jeong-Jik (Department of Quality Management, Korea Institute of Construction Materials) ;
  • Cheong, Jae-Chul (Drug Aanlysis Laboratory, Supreme Prosecutors' Office) ;
  • Suh, Sung-Ill (Drug Aanlysis Laboratory, Supreme Prosecutors' Office) ;
  • In, Moon-Kyo (Drug Aanlysis Laboratory, Supreme Prosecutors' Office)
  • Received : 2009.10.19
  • Accepted : 2010.01.18
  • Published : 2010.02.25

Abstract

For the evaluation of our laboratory's 11-nor-${\Delta}^9$-tetrahydrocannabinol-9-carboxylic acid (THCCOOH) urinalysis test, THCCOOH urinalysis test was carried out with Certified Reference Material (CRM). The used CRM was THCCOOH in freeze-dried urine produced by NIST as Standard Reference Material 1507b. Comparing the estimated value of our laboratory with CRM, the results was coincided in the confidence level of approximately 95%.

대검찰청 마약감식실은 대마 흡연여부를 판별하는 수단인 소변 중 대마 대사체 성분 분석법 에 대한 신뢰도 평가를 위하여 인증표준물질을 이용한 시험을 실시하였다. 시험에 사용된 인증표준물질은 미국 NIST에서 판매하는 Standard Reference Material 1507b로, 11-nor-${\Delta}^9$-tetrahydrocannabinol-9-carboxylic acid (THCCOOH)가 함유된 냉동 건조 소변이었다. NIST에서 구매한 인증표준물질의 농도값과 실험실에서 측정한 농도값을 비교 평가해 본 결과, 약 95% 신뢰수준에서 일치하였다.

Keywords

References

  1. '2008 Drug control in Korea', Supreme Prosecutors' Office.
  2. V. Rajananda, V. Navarantnam and N. K. Nair, 'Analytical methods for the identification of the principal cannabinoids metabolite in urine', 113 V. Navarantnma Ed., National Drug Research Centre Universiti Sains, Malaysia, 1985.
  3. 'TDx/TDxFLx; Cannabinoids', 10, Abbott Laboratories, U.S.A, 1994.
  4. R. A. Gustafson, E. T. Moolchan, A. Barnes, B. Levine and M. A. Huestis, J. Chromatogr. B, 798, 145-154(2003). https://doi.org/10.1016/j.jchromb.2003.09.022
  5. P. Kintz, D. Machart, C. Jamey and P. Mangin, J. Anal. Toxicol., 19(5), 304-306(2000).
  6. P. Kintz and V. Cirmele, Biomed. Chromatogr., 11, 371-376(1997). https://doi.org/10.1002/(SICI)1099-0801(199711)11:6<371::AID-BMC685>3.0.CO;2-Y
  7. C. Staub, J. Chromatogr. B, 733, 199-126(1999).
  8. M. A. Huestis, J. M. Mitchell and E. J. Cone, J. Anal. Toxicol., 20(6), 441-452(1996). https://doi.org/10.1093/jat/20.6.441
  9. M. A. Elsohly and S. Feng,, J. Anal. Toxicol., 20(4), 329-335(1998).
  10. D. A. Armbruster, R. H. Schwarzhoff, E. C. Hubster and M. K. Liserio, Clin. Chem., 39, 2137-2141(1993).
  11. P. M. Kemp, I. K. Abukhalaf, J. E. Manno, B. R. Manno, D. D. Alford, M. E. Mcwilliams, F. E. Nixon, M. J. Fitzgerald, R. R. Reeves and M. J. Wood, J. Anal. Toxicol., 19(5), 292-298(1995). https://doi.org/10.1093/jat/19.5.292
  12. H. Teixeira, P. Proenca, A. Castanheira, S. Santos, M. Lopez-Rivadulla, F. Corte-Real, E. P. Marques and D. N. Vieira, Forensic Sci. Int., 146, Suppl: S61-63(2004). https://doi.org/10.1016/j.forsciint.2004.09.002
  13. G. M. Aballero, C. D'Angelo, M. S. Fraguio and O. T. Cenrurion, J. Chromatogr. Sci., 42(10), 540-544(2004). https://doi.org/10.1093/chromsci/42.10.540
  14. H. Teixeira, P. Proenca, A. Verstanete, F. Corte-Real, and D. N. Vieira, Forensic Sci. Int., 150, 205-211(2006).
  15. M. A. Elsohly, S. Feng, W. J. Kopycki, T. P. Murply, A. B. Jones, A. Davis and D. Carr, J. Anal. Toxicol., 21(3), 240-242(1997). https://doi.org/10.1093/jat/21.3.240
  16. ISO Guide 35, 'Ceritification of reference materialgeneral and statistical principles', ISO, Geneva.
  17. A. M. H. vander Veen, Accred. Qual. Assur., 7, 2-6(2002). https://doi.org/10.1007/s00769-001-0414-2
  18. 측정불확도 표현지침, 한국표준과학연구원 (1998).
  19. 측정결과의 불확도 산정 및 표현을 위한 지침, KOLAS(Korea Laboratory Accreditation Scheme) (2000).
  20. 숙련도시험운영기준, KOLAS(Korea Laboratory Accreditation Scheme) (2007).
  21. 김진영, 정재철, 서승일, 서용준, 이정직, 김종상, 인문교, 약학회지, 52, 480-487(2008).
  22. 정재철, 김진영, 인문교, 정원조, 한국분석과학회지, 19(5), 441-448(2006).
  23. 최종오, 소헌영, 우진춘, 황의진, 한국분석과학회지, 15(6), 580-583(2002).

Cited by

  1. Development and Validation of Reference Material for Proficiency Testing of Blood Heavy Metals in Environmental Biomonitoring vol.42, pp.6, 2016, https://doi.org/10.5668/JEHS.2016.42.6.450