References
- Abumi K, Shono Y, Ito M, Taneichi H, Kotani Y, Kaneda K : Complications of pedicle screw fixation in reconstructive surgery of the cervical spine. Spine (Phila Pa 1976) 25 : 962-969, 2000 https://doi.org/10.1097/00007632-200004150-00011
- Aryan HE, Newman CB, Nottmeier EW, Acosta FL Jr, Wang VY, Ames CP : Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients : modification of the Harms and Goel technique. J Neurosurg Spine 8 : 222-229, 2008 https://doi.org/10.3171/SPI/2008/8/3/222
- Claybrooks R, Kayanja M, Milks R, Benzel E : Atlantoaxial fusion : a biomechanical analysis of two C1-C2 fusion techniques. Spine J 7 : 682-688, 2007 https://doi.org/10.1016/j.spinee.2006.08.010
- Fountas KN, Kapsalaki EZ, Machinis T, Robinson JS : Extrusion of a screw into the gastrointestinal tract after anterior cervical spine plating. J Spinal Disord Tech 19 : 199-203, 2006 https://doi.org/10.1097/01.bsd.0000164164.11277.49
- Gazzeri R, Tamorri M, Faiola A, Gazzeri G : Delayed migration of a screw into the gastrointestinal tract after anterior cervical spine plating. Spine (Phila Pa 1976) 33 : 268-271, 2008 https://doi.org/10.1097/BRS.0b013e31816b8831
- Geyer TE, Foy MA : Oral extrusion of a screw after anterior cervical spine plating. Spine (Phila Pa 1976) 26 : 1814-1816, 2001 https://doi.org/10.1097/00007632-200108150-00019
- Grob D, Magerl F : [Surgical stabilization of C1 and C2 fractures.] Orthopade 16 : 46-54, 1987
- Gunnarsson T, Massicotte EM, Govender PV, Raja Rampersaud Y, Fehlings MG : The use of C1 lateral mass screws in complex cervical spine surgery : indications, techniques, and outcome in a prospective consecutive series of 25 cases. J Spinal Disord Tech 20 : 308-316, 2007 https://doi.org/10.1097/01.bsd.0000211291.21766.4d
- Harms J, Melcher RP : Posterior C1-C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26 : 2467-2471, 2001 https://doi.org/10.1097/00007632-200111150-00014
- Hong JT, Lee SW, Son BC, Sung JH, Kim IS, Park CK : Hypoglossal nerve palsy after posterior screw placement on the C-1 lateral mass. Case report. J Neurosurg Spine 5 : 83-85, 2006 https://doi.org/10.3171/spi.2006.5.1.83
- Kim YS, Lee JK, Kim JH, Kim SH : Post-traumatic atlantoaxial rotatory dislocation in an adult treated by open reduction and C1-C2 transpedicular screw fixation. J Korean Neurosurg Soc 41 : 248-251, 2007 https://doi.org/10.3340/jkns.2007.41.4.248
- Kuroki H, Rengachary SS, Goel VK, Holekamp SA, Pitkanen V, Ebraheim NA : Biomechanical comparison of two stabilization techniques of the atlantoaxial joints: transarticular screw fixation versus screw and rod fixation. Neurosurgery 56 : 151-159; discussion 151-159, 2005
- Melcher RP, Puttlitz CM, Kleinstueck FS, Lotz JC, Harms J, Bradford DS : Biomechanical testing of posterior atalntoaxial fixation techniques. Spine (Phila Pa 1976) 27 : 2435-2440, 2002 https://doi.org/10.1097/00007632-200211150-00004
- Menendez JA, Wright NM : Techniques of posterior C1-C2 stabilization. Neurosurgery 60 : S103-S111, 2007
- Mixter SJ, Osgood RB : IV. Traumatic Lesions of the Atlas and Axis. Ann Surg 51 : 193-207, 1910 https://doi.org/10.1097/00000658-191002000-00004
- Ondra SL, Marzouk S, Ganju A, Morrison T, Koski T : Safety and efficacy of C2 pedicle screws placed with anatomic and lateral C-arm guidance. Spine (Phila Pa 1976) 31 : E263-E267, 2006 https://doi.org/10.1097/01.brs.0000214882.34674.be
- Papagelopoulos PJ, Currier BL, Hokari Y, Neale PG, Zhao C, Berglund LJ, et al. : Biomechanical comparison of C1-C2 posterior arthrodesis techniques. Spine (Phila Pa 1976) 32 : E363-E370, 2007 https://doi.org/10.1097/BRS.0b013e318060cc65
- Rhee WT, You SH, Kim SK, Lee SY : Troblesome occipital neuralgia developed by C1-C2 Harms construct. J Korean Neurosurg Soc 43 : 111-113, 2008 https://doi.org/10.3340/jkns.2008.43.2.111
- Sahjpaul RL : Esophageal perforation from anterior cervical screw migration. Surg Neurol 68 : 205-209; discussion 209-210, 2007 https://doi.org/10.1016/j.surneu.2006.09.032
- Yablon IG, Cowan S, Mortara R : The migration of a Harrington rod after cervical fusion. Spine (Phila Pa 1976) 18 : 356-358, 1993 https://doi.org/10.1097/00007632-199303000-00009
Cited by
- Migration of Rod into Retroperitoneal Region: A Case Report and Review of the Literature vol.11, pp.4, 2010, https://doi.org/10.14245/kjs.2014.11.4.241
- A case report of rod migration into cerebellum through foramen magnum after lateral mass fixation of cervical spine vol.158, pp.4, 2010, https://doi.org/10.1007/s00701-015-2693-0