DOI QR코드

DOI QR Code

The Validity Test of Upper·Forearm Coordinate System and the Exploratory Analysis of the Interactive Effect between Flexion/Extension and Pronation/Supination during Elbow Joint Motion

주관절 운동의 상완·전완좌표계 타당도 및 굴곡/신전과 회내/회외의 상호작용

  • Kim, Jin-Uk (Department of Physical Education & Sports, College of Natural Science, Kunsan National University)
  • 김진욱 (군산대학교 자연과학대학 체육학과)
  • Received : 2010.04.30
  • Accepted : 2010.06.12
  • Published : 2010.06.30

Abstract

The axes of upper forearm coordinate system have been considered as principal axis of each segment which was component of elbow joint. The purpose of this study was to verify whether the mean direction(principal axis) of instantaneous axes of rotation for pure flexion/extension motion coincided with the flexion/extension axis of upper forearm coordinate system. The same procedure was done for pronation/supination motion. Furthermore, it was tested indirectly that there was an interaction effect between the two rotational motions. The results showed that most segment coordinate axes statistically were not consistent with the mean directions of flexion/extension and pronation/supination axes of rotation. From the results, it would be concluded that the ISB coordinate systems was proved to be a little valid for human movement analysis. There also was an effect of pronation/supination angles on flexion/extension motion.

Keywords

References

  1. 김진욱(2009). 방향통계학을 이용한 슬관절 회전축자료의 분석. 한국체육학회지, 48, 615-623.
  2. Campbell, A. C., Lloyd, D. G., Alderson, J. A., & Elliott, B. C.(2009). MRI development and validation of two new predictive methods of glenohumeral joint center location identification and comparison with established techniques. Journal of Biomechanics, 42, 1527-1532. https://doi.org/10.1016/j.jbiomech.2009.03.039
  3. Challis, J. H.(1995). A procedure for determining rigid body transformation parameters. Journal of Biomechanics, 28, 733-737. https://doi.org/10.1016/0021-9290(94)00116-L
  4. Cutti, A. G., Garofalo, P., Davalli, A., & Cappello, A.(2006). How accurate is the estimation of elbow kinematics using ISBrecommended joint coordinate systems? Gait & Posture,24s, s36-s37.
  5. Figueiredo, A.(2006). Two-way analysis of variance for data froma concentrated bipolar Watson distribution. Journal ofApplied Statistics, 33, 575-581. https://doi.org/10.1080/02664760600679619
  6. Fisher, N. I., Lewis, T., & Embleton, B. J. J.(1993). Statisticalanalysis of spherical data. New York, NY : CambridgeUniversity Press.
  7. Goto, A., Moritomo, H., Murase, T., Oka, K., Sugamoto, K.,Arimura, T., Nakajima, Y., Yamazaki, T., Sato, Y.,Tamura, S., Yoshikawa, H., & Ochi, T.(2004). In vivoelbow biomechanical analysis during flexion : Threedimensional motion analysis using magnetic resonanceimaging. Journal of Shoulder and Elbow Surgery, 13,441-447. https://doi.org/10.1016/j.jse.2004.01.022
  8. Greenwood, D. T.(2003). Advanced dynamics. New York, NY :Cambridge University Press.
  9. Kontaxis, A., Cutti, A. G., Johnson, G. R., & Veeger, H. E.J.(2009). A framework for the definition of standardizedprotocols for measuring upper-extremity kinematics.Clinical Biomechanics, 24, 246-253. https://doi.org/10.1016/j.clinbiomech.2008.12.009
  10. Mardia, K. V., & Jupp, P.(2000) Directional statistics (2ndedition). West Sussex, England : John Wiley and SonsLtd.
  11. Meskers, C. G. M., van der Helm, F. C. T., Rozendaal, L. A., &Rozing, P. M.(1998). In vivo estimation of glenohumeraljoint rotation center from scapular bony landmarks bylinear regression. Journal of Biomechanics, 31, 93-96.
  12. Neumann, D. A.(2002). Kinesiology of the musculoskeletal system :Foundations for physical rehabilitation. St. Louis, MO :Mosby, Inc.
  13. Nordin, M., & Frankel, V. H.(2001). Basic biomechanics of themusculoskeletal system (3rd ed.). Lippincott & WilliamsPublisher.
  14. Prokopenko, R. A., Frolov, A. A., Biryukova, E. V., &Robi-Brami, A.(2001). Assessment of the accuracy of ahuman arm model with seven degrees of freedom.Journal of Biomechanics, 34, 177-185. https://doi.org/10.1016/S0021-9290(00)00179-2
  15. Soderkvist, I., & Wedin, P.(1993). Determining the movements ofthe skeleton using well-configured markers. Journal ofBiomechanics, 26, 1473-1477. https://doi.org/10.1016/0021-9290(93)90098-Y
  16. Spoor, C. W., & Veldpaus, F. E.(1980). Rigid body motioncalculated from spatial coordinate of markers. Journal ofBiomechanics, 13, 391-393. https://doi.org/10.1016/0021-9290(80)90020-2
  17. Stephens, M. A.(1982). Use of the von Mises distribution toanalyse continuous proportions. Biometrika, 69, 197-203. https://doi.org/10.1093/biomet/69.1.197
  18. van Andel, C. J., Wolterbeck, N., Doorenbosch, C. A. M., Veeger,H. E. J., & Harlaar, J.(2008). Complete 3D kinematics ofupper extremity functional tasks. Gait & Posture, 27,120-127. https://doi.org/10.1016/j.gaitpost.2007.03.002
  19. Veeger, H. E. J., Yu, B., An, K. N., & Rozendal, R. H.(1997).Parameters for modeling the upper extremity. Journal ofBiomechanics, 30, 647-652. https://doi.org/10.1016/S0021-9290(97)00011-0
  20. Woltring, H. J.(1990). Data processing and error analysis. In N.Berme, & A. Cappozzo (Eds.), Biomechanics of humanmovement : Applications in rehabilitation, Sport andErgonomics, 203-237. Washington, OH : BertecCorporation.
  21. Wu, G., van der Helm, F. C. T., Veeger, H. E. J., Makhsous, M.,Roy, P. V., Anglin, C., Nagels, J., Karduna, A. R.,McQuade, K., Wang, X., Werner, F. W., & Buchholz,B.(2005). ISB recommendation on definitions of jointcoordinate systems of various joints for the reporting ofhuman joint motion - part II : shoulder, elbow, wristand hand. Journal of Biomechanics, 38, 981-992. https://doi.org/10.1016/j.jbiomech.2004.05.042
  22. Zampagni, M. L., Casino, D., Martelli, S., Visani, A., & Marcacci,M.(2008). A protocol for clinical evaluation of thecarrying angle of the elbow by anatomic landmarks.Journal of Shoulder and Elbow Surgery, 17, 106-112. https://doi.org/10.1016/j.jse.2007.03.028

Cited by

  1. Comparative Study on Axes of Rotation Data by Within-Subjects Designs vol.26, pp.6, 2013, https://doi.org/10.5351/KJAS.2013.26.6.873
  2. Comparisons Among Functional Methods of Axis of Rotation Suitable for Describing Human Joint Motion vol.21, pp.4, 2011, https://doi.org/10.5103/KJSB.2011.21.4.449