DOI QR코드

DOI QR Code

Reinforcing Effect of Thin-wall at Serviceability Condition

상시하중상태에서 박벽의 보강효과에 대한 연구

  • Received : 2009.01.07
  • Accepted : 2010.02.19
  • Published : 2010.03.31

Abstract

For the reasonable analysis of design problems for agricultural facilities, considered the reinforcing effect of thin-wall. The most of agricultural structure is constructed small scale and have many purposes. Thus it has been designed temporary rather than permanent structure, and has relatively large slenderness ratio, small section and semi-rigid condition. Therefore many agricultural facilities are consist of relatively strong frame with weak wall at the viewpoint of stiffness and have not been reflected in the design. But the tension field influences to collapse of structure have already known. Therefore, we need quantification the effect of tension field at structural analysis. In this study, present the method of quantification the effect of tension field that came out thin-plate surrounded by high stiffness frame. The numerical results show that the effect of tension field effect for thin-wall is about 5% of the sectional area of frame in study agricultural facilities.

Keywords

References

  1. AASHO, 1973. Standard specifications for highway bridges, 11th ed., American Association of State Highway Officials, Washington DC.
  2. AISC, 1997. Seismic provisions for structural steel buildings, AISC, Chicago.
  3. AISC, 1999. Load and resistance factor design specification, AISC, Chicago.
  4. Besler, K., 1963. Strength of plate girders in shear, Transactions of the ASCE 128(2): 683-719.
  5. Chung, L., H. S. Park, Kim, & J. S. Kim, 1991. Similitude law of reinforced concrete structures subjected to dynamic loading, The Architectural Institute of Korea 11(2): 541-546.
  6. Kim, N. S., J. H. Lee, and S. P. Chang, 2004. An equivalent multi-phase similitude law for pseudodynamic test on small-scale RC models, Journal of the Earthquake Engineering Society of Korea 7(6): 101-108. https://doi.org/10.5000/EESK.2003.7.6.101
  7. Lee, M. H., S. H. Oh, M. H. Yoon, and T. S. Moon, 2006. Structural behaviors of steel-plate shear panels due to aspect ratios and stiffener-reinforced types (I) monotonous loading test, Journal of Korean Society of Steel Construction 22(5): 129-136.
  8. Lee, S. C., D. Y. Yoon, and U. Y. Jeong, 2003. Experimental study on the ultimate behavior of steel box girder webs, Korean Society of Civil Engeneers 23(6): 1295-1302.
  9. Park, H. G., J. H. Kwack, S. W. Jeon, and W. K. Kim, 2007. Structural capacity of steel plate walls according to various infill plate details, Journal of Korean Society of Steel Construction 19(1): 1-67.
  10. Park, H. S., J. G. Min, and L. Chung, 1992. Modeling techniques of reinforced concrete members based on the similitude requirements, The Architectural Institute of Korea 8(1): 191-198.
  11. Shin, D. G. 1998. Postbuckling behavior of rectangular plates considering phenomenon of buckled mode change, Korean Society of Civil Engeneers 18(1): 111-123.
  12. Steigmann, D. J., 1990. Tention filed theory, Proc. of the Royal Society of London, Series A, Mathematical and Physical Sciences 429(1876): 141-173. https://doi.org/10.1098/rspa.1990.0055
  13. Thorburn, L. J., G. L. Kulak and C. J. Montgomery, 1983. Analysis of Steel Plate Shear Walls, Structural Engineering Report, 107, University of Alberta, Canada.
  14. Wagner, H., 1931. Flat sheet metal girder with very thin metal web, Part I - General Theories and Assumptions, National Advisory Committee for Aeronautics, Technical Memorandum, 604.
  15. Wilson, J. M., 1886, On specifications for strength of iron bridges, Transactions of the ASCE 15(1): 401-403 and 489-490.
  16. Woo, S. S., S. H. Lee, and L. Chung, 2007. Shaking table test of small scale 5-story RC structure with tuned liquid damper, The Architectural Institute of Korea 23(2): 3-8.
  17. Yang, H. G., J. W. Seo, N. S. Cho, and S. P. Chang, 2006. Shaking table test of small scale 5-story RC structure with tuned liquid damper, Earthquake Engineering Society of Korea 10: 123-134.
  18. Yun, J. J., 1992. A study on the similitude of precast concrete panel structure using one-third scale subassemblage model, Journal of the Korea Concrete Institute 4(3): 123-134.