Abstract

Purpose: The purpose of this study was to investigate the change of microstructures and mechanical properties of pure titanium casting specimens as a function of mold temperatures. Methods: The pure titanium castings were fabricated using the centrifugal vacuum casting method with different mold temperatures of $200{\sim}500^{\circ}C$. The resulting castings were characterized by optical microscopy, scanning electron microscopy, energy dispersive X-ray spectroscopy and vicker,s hardness tester. Results: In case of the mold temperatures over $400^{\circ}C$, the porosity, surface crack and large grain size were observed in resulting castings. Conclusion: In this work, The most suitable mold temperature in casting of pure titanium was $300^{\circ}C$.

Keywords

References

  1. 고영건, 염종택, 신동혁, 이종수. 초립결정립 순-Ti의미 세조직및상온인장물성. 대한금속재료학회지, 43(8), 524-532, 2005.
  2. 문수. 치과주조용 티타늄합금 및 주형재 개발에 대한 연구. 박사학위논문, 국민대학교, 2006.
  3. 박양순, 한선호, 송규석. 고온(${300{\sim}1000^{\circ}C}$)에서 티타늄 금속시편의 표면 산화거동. Analytical Science & Technology, 22(6), 464-470, 2009.
  4. 박영준, 강후원, 이용렬, 송호준, 김민강. 치과용 Ti-Zr- Cr계 합금에서 Cr함량변화가 부식 저항성에 미치 는 영향. 대한치과기재학회지, 31(4), 273-282, 2004.
  5. 서동인, 한전건. Ti-6Al-4V합금의 가공열처리에 따른 조직 및 피로 특성에 관한 연구. 대한금속학회지, 28(1), 23-31, 1990.
  6. 송광엽. 치과주조용 티타늄합금의 주조성에 관한 연구. 서울대학교 대학원 박사논문, 1992.
  7. 이도재, 김대환, 박효병, 이경구. 생체용 Ti-15Sn계 합금의 내식성 및 기계적 성질에 관한 연구. 한국주조공학, 20(3), 209-215, 2000.
  8. 이순현, 정용훈, 최한철, 고영무. Ti 및 Ti-6Al-4V합금의 부식거동. 대한치과기공학회지, 30(1), 25-31, 2008.
  9. 주동현, 이용렬, 정영화, 양홍서, 박상원, 이도재, 송호준, 박영준. 티타늄 열처리 조건에 따른 동전위 양극분극특성 및 표면미세구조변화. 대한치과기재학회지, 29(2), 145-156, 2002.
  10. 차성수. Ti-Pd계 합금의 미세조직변화에 따른 부식거동. 대한치과기공학회, 30(2), 9-16, 2008.
  11. Hensten PA. Matal Allergy in Dentistry. Proceedings of 3rd, International Symposium on Titanium in Dentistry(Australia), 113-117, 1995.
  12. Long M, Rack HJ. Titanium Alloy in Total Joint Replacement-a Materials Science Perspective. Biomaterials, 19, 1621-1639, 1998. https://doi.org/10.1016/S0142-9612(97)00146-4
  13. Miyazaki T. Recent progress in titanium dental casting technologies and current problems for a clinical application. Quintessence, 11(1), 171-181, 1992.
  14. Moon S, Jung JY, Kim GJ, Lee JH. Effect of Cooling Followed by Casting on the Iterfacial and Mechanical Properties of Dental CP-Ti Casts. J Biomed Eng Res, 24(5), 375-380, 2003.
  15. Moon S. Practice of the Pure Titanium Prosthesis in korea. Q.D.T., 24(9), 1242-1243, 1999.
  16. Okazaki Y, Rao S, Asao S, Tateishi T, Katsuda S, Furukiy. Effect of Ti,Al and V concentration on the relative growth ratio of bio-cells. J Japan Inst Metals 60(9), 890-896,1996. https://doi.org/10.2320/jinstmet1952.60.9_890
  17. Wang ZG, Lian J, Huang XQ. J Alloy Comp, 384, 93-97, 2004. https://doi.org/10.1016/j.jallcom.2004.04.084
  18. Wang K. The use of Titanium for Medical Application in the USA. Mat Sci Eng, A312, 134-137, 1996.
  19. Yoshimitsu Okazaki. Effect of Alloying Elements on Mechanical Properties of Titanium Alloys for Medical Implants. J Japan Inst Metals, 57(3), 332-337, 1993. https://doi.org/10.2320/jinstmet1952.57.3_332