DOI QR코드

DOI QR Code

Enantioseparation and Determination of Sibutramine in Pharmaceutical Formulations by Capillary Electrophoresis

  • Zhu, Hongmei (College of Pharmacy, Chungnam National University) ;
  • Wu, Enqi (College of Pharmacy, Chungnam National University) ;
  • Chen, Jianbo (College of Pharmacy, Chungnam National University) ;
  • Men, Chuvan (College of Pharmacy, Chungnam National University) ;
  • Jang, Yu-Seon (College of Pharmacy, Chungnam National University) ;
  • Kang, Won-Ku (College of Pharmacy, Taegu Catholic University) ;
  • Choi, Jung-Kap (College of Pharmacy, Chonnam National University) ;
  • Lee, Won-Jae (College of Pharmacy, Chosun University) ;
  • Kang, Jong-Seong (College of Pharmacy, Chungnam National University)
  • Received : 2009.12.07
  • Accepted : 2010.04.07
  • Published : 2010.06.20

Abstract

Sibutramine enantiomers were separated successfully by capillary zone electrophoresis using substituted cyclodextrins as chiral selectors. The effects of cyclodextrin concentration, pH, voltage, buffer type, and electrolyte concentration on the migration time and resolution of enantiomers were examined. Separation of sibutramine enantiomers on an unmodified fused silica capillary (total length, 54 cm; effective length, 45 cm) was achieved using a mixed buffer of 20 mM phosphate/10 mM citrate containing either 5 mM methyl-${\beta}$-cyclodextrin (pH 4.3) or 5 mM carboxymethyl-${\beta}$-cyclodextrin (pH 6.5). Samples were injected with a pressure of 50 mbar for 5 s and were detected at a wavelength of 223 nm. The established method showed good precision and accuracy, with intra- and inter-day variations of less than 2.9 and 4.7%, respectively, and recoveries of 95.7 - 103.8%. The stability constants of (R)- and (S)-sibutramine demonstrated that the resolution of sibutramine enantiomers was attributable primarily to the difference in stability constants. When this optimized method was applied to the determination of sibutramine enantiomers in commercial drug formulations, it proved to be economical and convenient, affording sufficient accuracy, precision, and reproducibility as well as sensitivity and selectivity.

Keywords

References

  1. Heal, D. J.; Cheetham, S. C.; Prow, M. R.; Martin, K. F.; Buckett,W. R. Br. J. Pharmacol. 1998, 125, 301. https://doi.org/10.1038/sj.bjp.0702067
  2. Stock, M. J. Int. J. Obes. Relat. Metab. Disord. 1997, 21, S25.
  3. Bodhankar, S. L.; Thakurdesai, P. A.; Singhal, S.; Gaur, V. Indian J. Physiol. Pharmacol. 2007, 51, 175.
  4. Link, M.; Novotna, R.; Suchanova, B.; Skalova, L.; Wsol, V.;Szotakova, B. J. Pharm. Pharmacol. 2005, 57, 405. https://doi.org/10.1211/0022357055678
  5. Bae, K.; Noh, K.; Jang, K.; Kim, S.; Yong, C. S.; Choi, H. G.; Kang, J. S.; Chen, J. B.; Ma, E. S.; Lee, M. H.; Shin, B. S.; Kwon,K.; Kang, W. K. J. Pharm. Biomed. Anal. 2009, 50, 267. https://doi.org/10.1016/j.jpba.2009.04.024
  6. Glick, S. D.; Haskew, R. E.; Maisonneuve, I. M.; Carlson, J. N.;Jerussi, T. P. Eur. J. Pharmacol. 2000, 397, 93. https://doi.org/10.1016/S0014-2999(00)00216-8
  7. Radhakrishna, T.; Narayana, C. L.; Rao, D. S.; Vyas, K.; Reddy,G. O. J. Pharm. Biomed. Anal. 2000, 22, 627. https://doi.org/10.1016/S0731-7085(99)00303-9
  8. Pan, Y.; Yu, L.; Yang, X.; Yang, L.; Guo, X. Shenyang Yaoke Daxue Xuebao 2006, 23, 521.
  9. Singh, A. K.; Pedro, L. G.; Gomes, F. P.; Yano, H. M.; Auricchio,M. T.; Kedor-Hackmann, E. R.; Santoro, M. I. J. AOAC Int. 2008,91, 572.
  10. Xiao, S.; Liu, Y.; Chen, H.; Chen, Z.; Xia, Z. Fenxi Huaxue 2005,33, 1761.
  11. Huang, F.; Chen, H.; Xia, Z. Yaowu Fenxi Zazhi 2004, 24, 113.
  12. Tanaka, Y.; Terabe, S. J. Chromatogr. B 2002, 768, 81. https://doi.org/10.1016/S0378-4347(01)00488-1
  13. Hsiao, J. Y.; Wu, S. H.; Ding, W. H. Talanta 2006, 68, 1252. https://doi.org/10.1016/j.talanta.2005.07.029
  14. Phuong, N. T.; Lee, K. A.; Kim, K. H.; Choi, J. K.; Kim, J. M.;Kang, J. S. Arch. Pharm. Res. 2004, 27, 1290. https://doi.org/10.1007/BF02975896
  15. Park, K. L.; Kim, K. H.; Jung, S. H.; Lim, H. M.; Hong, C. H.;Kang, J. S. J. Pharm. Biomed. Anal. 2002, 27, 569. https://doi.org/10.1016/S0731-7085(01)00580-5
  16. Uselova-Vcelakova, K.; Zuskova, I.; Gas, B. Electrophoresis2007, 28, 2145. https://doi.org/10.1002/elps.200600780

Cited by

  1. Detection of sibutramine and phenolphthalein in functional foods using capillary electrophoresis vol.8, pp.3, 2016, https://doi.org/10.1039/C5AY02973B
  2. Fundamental aspects of chiral electromigration techniques and application in pharmaceutical and biomedical analysis vol.55, pp.4, 2011, https://doi.org/10.1016/j.jpba.2010.11.018
  3. Application of cyclodextrins in chiral capillary electrophoresis vol.35, pp.19, 2010, https://doi.org/10.1002/elps.201400145